DYTECH GT06N User Manual Download Page 18

command 

Setting 

920#radius#way# 

920#1#2#

 

Cancel 

921# 

921# 

Command 

Description 

Setting  Geo-fence  alarm,  radius  from  1-

100,

 

Unit: 100 meter. 

Alarming 

1, calling 2, texting 

Out  Geo-fence  1  time,  the  Geo-fence 

canceled. 

Feedback 

Set 

Enclosure

-2 OK / Cancel 

Enclosure

 OK 

 

19)Position 

Text 

command 

Parameter 

Sample 

command 

988# 

988# 

Command 

Description 

Check  the  longitude  and  altitude    and 

other information of the device 

Command 

Feedback 

Reply  with  longitude  and  altitude,  speed 

and IMEL. 

 

20)Google Link 

Text 

Parameter 

Sample 

Summary of Contents for GT06N

Page 1: ...ice smoothly and correctly Please make sure to read this manual carefully before using this product Please note that specification and information are subject to changes without prior notice in this manual Any change will be integrated in the latest release The manufacturer assumes no responsibility for any errors or omissions in this document ...

Page 2: ... SMS or internet Overview of the characteristics 1 GSM 850 900 1800 1900MHZ 2 GPS position 3 Auto set APN 4 200Mah Battery inside Power Cut alarm 5 Motion detect save GPRS flow and power 6 GEO fence Alarm 7 SOS Alarm 8 Vibration Alarm 9 ACC Alarm 10 Speed Alarm 11 Voice Surveillance 12 Voltage Range DC 10V 40V 13 Enginee Cut off ...

Page 3: ...800 1900MHZ 2 GPRS Class12 TCP IP 3 Working Voltage 10V 40V DC 4 Working current 22mA 12VDC 5 Working current 12mA 24VDC 6 GPS locating time Cold start 38s Open sky Warm start 32s Hot start 2s Open sky 7 GPS Precision 10m 2D RM 8 Working temperature 20 70 9 Working humidity 20 80 RH ...

Page 4: ... will be flashing 5 3 The intermediate green LED GSM signal state GSM signal is normal green LED flashing No GSM signal the green LED light continuously 6 Installation 6 1 Prepare for installation 6 11 Product Check Open the packing box and check the device s model and accessories If the model is wrong or the accessories not complete please contact the dealer 6 12 Choose SIM card Please insert a S...

Page 5: ... Connect the device to the 10V 40V power supply 6 16 Install the device in the hidden place of the car The SIM card must be with GPRS function and enough deposit If your SIM card need input PIN when power on please cancel it 6 2 Installation The GPS tracker must be installed under professional personnel Note 1 Please install the device in the hidden place as followings 2 Avoid being placed with si...

Page 6: ... line is negative pole 7 2 The negative pole of power supply connects with ground or the metals Please do not connect with other ground lines 7 3 When finishing the power supply wire connection please make the plug of power supply to the device 8 The Device Working 8 1 Power on Connecting to the power Then the three LED indicators will light The device will upload the data to the online platform t...

Page 7: ... number 710 13500135000 711 13800138000 CENTER Del D01 D02 D01 D02 Command Description 1 Center number can control the oil and power and resume factory settings 2 Center number can receive the call and text of vibration alarm and over speeding alarm 3 SIM must display the income call number to control oil and power 4 Only 2 number can be center number 5 Change center number must resend the command...

Page 8: ...901 Command Description This directive is used to view Device Manager number Command Feedback Successful Setting Admin1 Admin2 3 Authorized Number Set Text command Parameter Sample Authorized Add 101 number 102 number 103 number 1 101 13800138000 2 102 12345678912 3 103 12345678912 Authorized Del D11 D12 D13 D11 D12 D13 ...

Page 9: ...needs to delete the previous number Command Feedback Successful Setting Add Authorization account 1 OK 4 View Authorized Number Text command Parameter Sample View authorized C10 C10 Command Description This directive is used to view the equipment authorization number Command Feedback Successful Setting Authorization 1 Authorization 2 Authorization 3 ...

Page 10: ...com operators For example APN request password please refer to Sample 1 and Sample 2 for no password Command Feedback Successful Setting SET APN OK 6 Set Server Text command Parameter Sample SERVER Parameter 803 SERVER port 1 803 www trac123 com 7018 2 803 47 243 91 120 6100 View SERVER CIP 1 CIP Command Description Change the IP and port when move to a new server port 10 65535 ...

Page 11: ...MEER Parameter setting 730 upload interval 730 20 Command Description Scope 0 10 60 seconds 0 no data uploading 10 60 means time interval the default value is 15 seconds Command Feedback Successful Setting SET TIMER OK 8 Static Time Interval Text command Parameter Sample STATIC SUP time interval SUP 5 ...

Page 12: ...ancel the continuous upload Text command Parameter Sample NUP NUP NUP Command Description This command is used to cancel sending data to the platform If need again to restore the uploading need to send TIMEER Parameter setting Command Feedback SET OK 10 Oil Cut Text command Parameter Sample RELAY Parameter1 222 222 Cut off oil and power ...

Page 13: ...ow 20KM H or in static state 4 When send the command the device will reply please waiting When the vehicle speed is over 20KM H the device will cut off the oil or the power when the speed below 20KM H Feedback Successful Setting Fuel cut has already been completed OK 11 GMT Text command Parameter Sample GMT 801 location time Zone 801 E8 801 W4 Command Description The default time zone is Beijing t...

Page 14: ...mple Open Vibration Alarm 911 911 VIBRATION Parameter 123 sensitivity alarming way 1 123 2 3 Set into vibration alarm time V123 2 1 V123 2 2 V123 1 Cancel vibration alarm 456 456 Command Description The sensitivity value of the vibration is from 1 to 5 1is the most sensitive and o is close Alarming ways 1 ...

Page 15: ...d Alarm Text command Parameter Sample SPEEDING Parameter SSA speed alarm way Or 667 speed alarm way 1 SSA 120 2 SSA 150 3 1 667 120 2 667 150 3 Command Description The speed scope is form 60 220 if the speed isnot in this cope the alarm is off Alarming 1 calling 2 texting 3 calling and texting Need set the center number and receiving number ...

Page 16: ... 14 ACC Alarm Text command Parameter Sample Open ACC Alarm 840 1 840 1 Close ACC ALARM 840 0 15 Reset Text command Parameter Sample RESET 930 930 Command Description Reset the device Feedback Successful Setting Reset system ok 16 Factory Text Parameter Sample ...

Page 17: ...ccessful Setting FACTORY OK 17 Language Setting command Parameter Sample LANG Parameter LANG1 LANG0 LANG1 1 CHINESE LANG0 ENGLISH Command Description When check the location it will reply the Chinese location in Chinese language setting while reply the URL link when in English language setting Feedback Successful Setting SET LANG OK 18 GEO fence Setting Text Parameter Sample ...

Page 18: ...2 texting Out Geo fence 1 time the Geo fence canceled Feedback Set Enclosure 2 OK Cancel Enclosure OK 19 Position Text command Parameter Sample command 988 988 Command Description Check the longitude and altitude and other information of the device Command Feedback Reply with longitude and altitude speed and IMEL 20 Google Link Text Parameter Sample ...

Page 19: ...ck Datetime 12 07 05 13 21 30 http maps google com maps q N22 540885 E113 95265 21 Version Text command Parameter Sample VERSION V00 V00 Command Description The command is to check the software version Command Feedback VERSION Xxxx BUILD 2012 07 05 10 12 22 Param Check Text command Parameter Sample ...

Page 20: ...ort TIMER moving uploading interval STATIC static uploading interval CENTER center number LANG language CN EN GMT time zone E W8 23 Status Check Text command Parameter Sample STATUS 902 902 Command Description The command is designed for checking the device s working status Command Feedback External power ON OFF GSM Signal HIGH MIDDLE LOW GPS FIXED UNFIXED ...

Page 21: ...SSS SSS Description Using Command Send this command to the tracker s number the tracker will call back to admin number 25 Monitor Voice Surveillance CALL command Parameter Sample Open Calling mode SS1 SS1 Return to Call back SS0 SS0 26 Wire cut Alarm Low Battery Alarm command Parameter Sample Disable 555 555 Enable 666 666 ...

Page 22: ...EI IMEI is in the label on the tracker Enter IMEI The default Password 123456 APP Please search TRAC123 in Google store or Apple store Or use mobile phone browser scan below QR code In production IP port have been writed in normally the tracker will be auto online if the tracker offline Please set APN by sms command ...

Page 23: ...possible You can call the device s number to check If not connected the device is out of signal If the GSM signals cannot reach your location please drive to the open sky If reminding the device SIM card is out of deposit please make deposit by the telecom operator If you can connect to the device when calling the SIM card has deposited and please check with your operator for GPRS function You als...

Page 24: ...ne area in order to judge if the network problem of operators 10 2 When GPS cannot receive the signals please drive in the open sky and ensure there is no metal thins on the device 10 3 When the device cannot receive the GSM signal please check the SIM card installation If the GSM signals cannot reach your location such as the basement please drive to the open sky ...