background image

Important

• This appliance is not intended for

use by young children or infirm
persons without supervision.

• Young children should be

supervised to ensure they do not
play with the appliance.

• Check that your electricity supply

corresponds to that shown on the
rating plate. The appliance must
only be used as rated.

• If the supply cable of the

appliance is damaged, disconnect
the appliance from the socket
outlet immediately. The supply
cable must be replaced by the
manufacturer or its service agent
or a similarly qualified person in
order to avoid a hazard.

• Do not use the cleaner if the cable

or plug are damaged or if the
cleaner has been damaged,
dropped or has come into contact
with water or any other liquid. In
these cases, contact the Helpline.

For your safety

Do not pull on 
supply cable.

Do not use cleaner
above you on stairs.

Do not place hands
under brushbar
when in use.

Do not use cleaner
to pick up water or
any other liquid. 

Do not use cleaner
near naked flames.

Do not leave cleaner
near heat sources.

Do not run over
supply cable.

Do not use cleaner
to pick up burning
objects of any kind.

DCO7 accessories 

AU

1800 239766

Unit 8, 7-11 Parraweena Road, 
Taren Point, Sydney NSW 2229.

NZ

0800 397 667

Avery Robinson Ltd, 151D Marua Road,
Ellerslie, Auckland.

Visit the Dyson website for product
information and to order accessories
and spares.

Dyson Customer Care

Every new Dyson domestic
vacuum cleaner has a 2 year
guarantee. 

If you have a query about your
Dyson, call the Dyson Customer
Helpline with your serial number
and details of where/when you
bought the cleaner.

Most queries can be solved
over the phone by one of our
factory-trained Helpline staff. 

If your cleaner needs attention
from our engineers, we aim to
have it repaired and tested
within 3-5 working days.

Your serial number can be
found on your rating plate
which is underneath the
machine beneath the wheels.

Note your serial number for
future reference:

helpline

DYSON LIMITED  MALMESBURY  SN16 ORP  ENGLAND  UK

230-240V 50Hz
1200 W

FOR PATENT INFORMATION SEE OPERATING MANUAL

02422-01-04

Zorb carpet-cleaning powder
(750g)*

Millions of tiny sponges absorb
dirt from the carpet, keeping
new carpets looking new with
none of the drawbacks of wet
cleaning.

• When vacuuming, certain carpets

may generate small static charges
in the clear bin. These are entirely
harmless and are not associated
with the mains supply. To minimise
any effect from this, do not put
your hand or insert any object into
the clear bin unless you have first
emptied it and rinsed it out with
cold water.

• Do not continue to use the cleaner 

if any part appears to be faulty,
missing or damaged.

• Do not carry out any maintenance

work other than that shown in this
manual or advised by the Helpline
and do not put anything into the
openings or moving parts of the
machine. 

• Only use parts produced or

recommended by Dyson; failure 
to do so could invalidate your
guarantee.

PN.04482-02-02  JN.7810  15.11.02

*item not approved by British Allergy Foundation.

The following items can be used with your DCO7. For further
information please see the order form, or visit the Dyson website
at www.dyson.com.au or www.dyson.co.nz

European conformity information: 

a sample of this product has been tested and found to be in conformity with the
following European Directives: 73/23/EEC Low Voltage (Safety) Directive,
93/68/ EEC  CE Marking Directive and 89/336/EEC EMC Directive. 

Mini Turbobrush

Rotating brushbar powered by
constant airflow improves pick-up
of pet hairs and other fibres.
Ideal for cleaning in confined
areas, e.g. car, stairs, upholstery.

<297mm>

www.dyson.com.au
www.dyson.co.nz

This product is protected by the following
Intellectual Property Rights:
Patent/Patent Application Nos:

EP1066115, EP0489565, EP0636338,

EP0800359, EP0800360, EP1098586,

EP1119281,

EP1119282,

EP1121043,

AU32024/01/EP01904105.2, US07/555,953,

US6425931,

US09/806,918, US6442791,

US09/806,930,

CA 2313177,

CA 2325953,

AU30432/99,

AU744298,

AU744408,

AU744362,

AU637272,

AU697029, 

AU14947/99,

AU30432/99,

AU50510/99,

AU30432/99, EP1066115,  US6425931,

AU744408, EP1119282, US09/806,918, 

AU744298, EP1119281, US6442791,

AU744362, EP1121043, US09/806,930,

GB 2342283, 

GB 2342282,

WO 02/067742,

WO 02/067753, WO 02/067751, GB 0104662.2,

GB 0109390.5, GB 2372468,

WO 

02/067750,

GB 2372469, 

WO 02/067756, GB 2374305, 

PCT/GB02/01378, GB 0109402.8,GB 2372435, 

WO 02/067757, GB 2372470, WO 02/067754,

WO 02/067752, GB 2372436.

Design registrations: GB 2099793, AU146419,
US29/147,074

Equivalent patents, registered designs and
applications exist in other countries. Equivalente
patente, registriertes Design und
Patentanmeldungen bestehen auch in anderen
Ländern. Des brevets équivalents, ainsi que des
designs et des applications déposés, existent
dans d’autres pays.

Summary of Contents for Radix Cyclone 8 DC07 brush control

Page 1: ...s may generate small static charges in the clear bin These are entirely harmless and are not associated with the mains supply To minimise any effect from this do not put your hand or insert any object...

Page 2: ...Please read this guide carefully before use User guide...

Page 3: ...ide wand down into hose DCO7 Lower cable winder Airway inspection U bend U bend release clip Hose Wand cap Upper cable winder Wand Wand release button On off switch Filter housing Valve release clips...

Page 4: ...ges Squeeze valve release catches to remove airway inspection valve C Check inside for blockages Lie cleaner on its front 1 Undo coloured fasteners using a coin and remove soleplate 2 Clear the brushb...

Page 5: ...t with lower cable winder from rear Check inside hose for blockages Important Please note that clearing blockages is not covered by your cleaner s guarantee Turn power off and unplug before starting t...

Page 6: ...Slot wand into top of machine and click into place Wind cable anti clockwise around cable winders and secure with clip Click tools into place...

Page 7: ...go hose and slide wand to end of hose A Wand mode Slide back wand cap and place tools directly on to wand handle Using the tools NB You can twist the brush and stair tool heads to make cleaning easie...

Page 8: ...Repeat steps 1 and 2 until water runs clear Allow 12 hours for filter to dry Make sure it is completely dry before replacing in machine Replace in filter housing and click back into machine 12 hrs 1 2...

Page 9: ...tch and remove filter housing from machine Filter should be washed every six months Circle your two washes Remove filter from housing Only blue foam and yellow cage should be washed Wash in cold water...

Page 10: ...care when cleaning stairs Reverse wand by inserting wand handle into hose C Reversed wand mode Fix tools or floortool on to end of wand For hard to reach areas Ensure wand cap is closed unless using...

Page 11: ...ase catch with thumb to remove bin assembly Option 1 recommended for asthma allergy sufferers Wipe outside of clear bin with a damp cloth before emptying A Place bin in bag and pull bin emptying trigg...

Page 12: ...he clear binTM We recommend the manufacturers emptying instructions should be strictly followed Assessment carried out by BAF indicate that an individual s exposure can be reduced but this does not me...

Reviews: