04
Symptom
Solution (in order)
Likely fault
See section
4 (page 21)
2 (page 10)
1 (page 05)
No air/reduced
airflow. Water
working.
Machine switching
on intermittently -
water and air.
or
Cutting out in use.
1. Fault with Air
hose assy.
2. Fault with Motor
bucket assy.
1. PCB assy (Tap)
failure.
2. Lens housing assy
failure.
3. Comms loom
assy failure.
4. Power supply assy
failure.
•Check PCB assy (Tap) for alignment
function. Replace if necessary.
•Check Lens housing assy is clean.
Replace if necessary.
•Ensure Comms loom assy
is adequately attached both ends.
•Test Comms loom assy for resistance
and replace if necessary.
•Check Power supply assy for function.
Replace if necessary.
•Ensure Air hose assy is adequately
sealed onto threaded Tap stem.
•Check Air hose assy for splits and
replace if necessary.
•Replace Motor and Bucket Service assy.
4 (page 21)
4 (page 21)
2 (page 12)&
4 (page 21)
2 (page 12)
2 (page 12)
Summary of Contents for AB09
Page 1: ...Issued July 13 dyson diagnostic Service manual...
Page 6: ...05 Section 1 Solenoid assembly removal 01 02 03 04 06 05...
Page 8: ...13 11 12 14 15 07 10 Section 1 Solenoid assembly fitting...
Page 9: ...18 17 16 08...
Page 12: ...11 08 07 10 09 11 AB11 only All models AB11 only All models AB09 10 only...
Page 20: ...02 03 05 04 01 Section 3 Backplate replacement fitting 19...
Page 22: ...Section 4 Internals of Tap replacement removal 03 04 06 05 01 02 21...
Page 23: ...22 09 11 10 08 07...
Page 24: ...14 15 13 12 23...
Page 26: ...Section 4 Internals of Tap replacement fitting 04 02 03 01 25...
Page 27: ...26 08 09 06 05 07...
Page 28: ...12 13 11 10 27...
Page 29: ...28 14 16 15 EPDM seal Gel seal 17...
Page 35: ...34 Motor Bucket Service Assy Filter Cage Service Assy Motorbucket assembly...