
EMS Operation
7-6
EMS-D10 Pilot’s User Guide
Change power on alarms status:
EMS > SETUP > GLOBAL > DOWN
▼
> SEL
►
> BACK
Set this parameter to “ON” to enable alarms before engine startup. With this parameter set to “OFF”, all alarms are
suppressed whenever ALL of the following conditions exist:
•
RPM less than 400
•
Oil pressure less than 20 PSI
•
First five minutes after master instrument power applied
All alarms are initialized when any of the above conditions are exceeded.
Test light/audio alarm(s):
EMS > SETUP > GLOBAL > ALARM CONFIG > DOWN
▼
> DOWN
▼
> SEL
►
Note: You must select an alarm to test using the UP
▲
/ DOWN
▼
buttons. Hold SEL
►
to test the selected alarm.
Info Item Configuration:
EMS > SETUP > GLOBAL > DOWN
▼
>
DOWN
▼
> DOWN
▼
> SEL
►
The INFO ITEM CONFIG submenu allows you to configure a variety
of different sensors as simple analog bars, on/off contacts, or text
items. Press the DOWN
▼
button to select the item, INFO ITEM
CONFIG
►
. Press SEL
►
to enter the INFO ITEM CONFIG submenu.
The first two info items are displayed on the EMS Main Page. Info
item 1 is at the top right of the page, and info item 2 is at the lower
right of the page. The other six info items are located on the Aux Page
and are numbered 2 through 5 on the top row and 6 through 8 on the
bottom row.
The Info Items Config submenu appears, allowing you to move up and