8
Crimp the supplied wire tap to the ORANGE
wire of the ECU harness (Fig. E).
This is the 3rd wire from the end, on the top
row of the ECU.
9
Attacht the GREY wire from the PCIII to the
wire tap (Fig. E).
It is recommended to use dielectric grease on
these connections.
10
Locate the stock O2 sensor connection. This
is under the fuel tank on the left hand side of
the frame (Fig. F).
11
Unplug this connection and install the
Dynojet O2 eliminator onto the stock wiring
harness.
The O2 sensor will not be connected to any-
thing at this time. It can be removed from the
exhaust if desired.
12
Reinstall the fuel tank and seat.
Fig. E
Fig. F
Fig. D
i625-411
www.powercommander.com
2008 Husqvarna TE250 - PCIII USB -
3
7
Plug the PCIII harness in-line of the stock-
wiring harness and injector (Fig. D).
PCIII connectors
Grey wire from PCIII
Stock connector
O2 sensor connection
Wire tap