8

Crimp the supplied wire tap to the ORANGE

wire of the ECU harness (Fig. E).  

This is the 3rd wire from the end, on the top

row of the ECU.

9

Attacht the GREY wire from the PCIII to the

wire tap (Fig. E).

It is recommended to use dielectric grease on

these connections.

10

Locate the stock O2 sensor connection.  This

is under the fuel tank on the left hand side of

the frame (Fig. F).

11

Unplug this connection and install the

Dynojet O2 eliminator onto the stock wiring

harness.

The O2 sensor will not be connected to any-

thing at this time.  It can be removed from the

exhaust if desired.

12

Reinstall the fuel tank and seat.

Fig. E

Fig. F

Fig. D

i625-411

www.powercommander.com

2008 Husqvarna TE250 - PCIII USB - 

3

7

Plug the PCIII harness in-line of the stock-

wiring harness and injector (Fig. D).

PCIII connectors

Grey wire from PCIII

Stock connector

O2 sensor connection

Wire tap