Dynex DX-EHB4 Network Hub

3

Link/Rx

—Indicates when the port has connected to the network (on) or when 

the port is receiving data (blinking). Each port has one Link/Rx LED.

Troubleshooting

If the 

Link/Rx

 port is connected but the LED is off, make sure that:

• Power for both the hub and the connected node is on.
• The network cable is not loose.
• The network cable is the correct type.
• The network cable is not broken.
• The network cable’s RJ-45 connectors have been wired correctly.
• The connected node’s network adapter is working.

Specifications

Data transfer rate.............................................................................. 10 Mbps
Protocol ...........................................................................................CSMA/CD
Network type ................................................................................... 10Base-T
Topology .................................................................................................. Star
Power requirement .................................................................................9VAC
Power consumption .................................................................5 W maximum
Operating temperature ........................................... 32° to 104°F (0° to 40° C)
Humidity tolerance ................................................5%-95% non-condensing

C

ABLE

 

AND

 

CONNECTOR

 

REQUIRED

 

SPECIFICATIONS

Cable type.................................................................................10Base-T UTP
Cable  characteristics...............................................0.4-0.6 mm (22-26 AWG)

8-wire (only four wires are used for 10Base-T)

Maximum  segment  length..................................................................100 m
Connectors.............................................................................................RJ-45
© 2005 Dynex. DYNEX and the DYNEX logo are trademarks of Best Buy Enterprise 
Services, Inc. Other brands and product names are trademarks or registered trade-
marks of their respective holders. Specifications and features are subject to 
change without notice or obligation.

DX-EHB4.fm  Page 3  Friday, April 29, 2005  4:14 PM

Summary of Contents for DX-EHB4

Page 1: ...USER GUIDE GUIDE DE L UTILISATEUR GUÍA DEL USUARIO 10Base T Ethernet Hub Concentrateur Ethernet 10Base T Concentrador 10Base T Ethernet DX EHB4 DX EHB4 fm Page 1 Friday April 29 2005 4 14 PM ...

Page 2: ...apter to the hub then plug the adapter into an AC power outlet 4 Connect the network cables as shown in the following diagram Interpreting the LEDs Power Indicates that the hub has power Collision Blinking indicates that data collisions are occurring on the network Collisions occur when two networked computers send data at the same time If this LED blinks frequently it means network traffic is hea...

Page 3: ... Data transfer rate 10 Mbps Protocol CSMA CD Network type 10Base T Topology Star Power requirement 9VAC Power consumption 5 Wmaximum Operating temperature 32 to 104 F 0 to 40 C Humidity tolerance 5 95 non condensing CABLE AND CONNECTOR REQUIRED SPECIFICATIONS Cable type 10Base T UTP Cable characteristics 0 4 0 6 mm 22 26 AWG 8 wire only four wires are used for 10Base T Maximum segment length 100 m...

Page 4: ...tion CA au concentrateur puis brancher l adaptateur dans une prise d alimentation CA 4 Connecter les câbles réseaux tel qu illustré sur le schéma suivant Signification des DEL Alimentation Indique que le concentrateur est alimenté Collision Clignotante indique l existence de collisions de données sur le réseau Les collisions se présentent lorsque deux ordinateurs en réseau transmettent des données...

Page 5: ...éseau 10Base T Topologie en étoile Alimentation requise 9 V CA Consommation de puissance 5 Wmaximum Température de fonctionnement 32 à 104 F 0 à 40 C Humidité tolérée 5 95 sans condensation CARACTÉRISTIQUES REQUISES POUR LE CÂBLE ET LE CONNECTEUR Type de câble 10Base T UTP Caractéristiques du câble 0 4 à 0 6 mm 22 à 26 AWG 8 fils seuls quatre fils sont utilisés pour le 10Base T Longueur maximum 10...

Page 6: ... el adaptador en un tomacorriente de CA 4 Conecte los cables de la red como se muestra en el diagrama siguiente Interpretación de los indicadores LED Alimentación Indica que el concentrador tiene alimentación eléctrica Colisión Si está parpadeando indica que están ocurriendo colisiones de datos en la red Las colisiones ocurren cuando dos computadoras conectadas a la red envían datos simultáneament...

Page 7: ...Especificaciones Velocidad de transferencia de datos 10 Mbps Protocolo CSMA CD Tipo de red 10Base T Topología Estrella Requisito de alimentación 9 V CA Consumo de potencia 5 Wmáximo Temperatura de funcionamiento 32 a 104 F 0 a 40 C Tolerancia de humedad 5 95 sin condensación ESPECIFICACIONES REQUERIDAS PARA EL CABLE Y EL CONECTOR Tipo de cable 10Base T UTP Características del cable 0 4 0 6 mm 22 2...

Page 8: ...ing LLC 7601 Penn Ave South Richfield MN 55423 U S A Distribué par Best Buy Purchasing LLC 7601 Penn Ave South Richfield MN 55423 É U Distribuido por Best Buy Purchasing LLC 7601 Penn Ave South Richfield MN 55423 U S A R1 DX EHB4 fm Page 8 Friday April 29 2005 4 14 PM ...

Reviews: