PowerDepot H5 series User Manual
20
1.For different inverter model,you need to set different DIP mode:
(1) Ensure the communication cable that communicates with the inverter is correct.
(2) When the battery works with GOODWE
、
Solis
、
LUX
、
Sofar
、
DEYE
、
VICTRON
、
IMEON
、
Infinisolar
、
Sungrow
、
SMA
、
RENAC
、
DELIOS
、
SAJ(CAN Comm)
,
Growatt HVM-ES/WPV(CAN port) ,before connecting you need confirm that the DIP switch
mode of the host module in PowerDepot H5 is 0010("# 3" to "ON" ,generally factory default is
this 0010 mode).
(3) If the battery communicates with the Axpert-king,Axpert-VMIII,Growatt SPH/SPA(CAN
comm)
、
GMDE
、
Saj(485 comm),change the host module DIP switch to 0100(
“
#2
”
to
“
ON
”
)
before connecting.
(4) If the battery communicates with the Growatt SPF HVM-P/ES/WPV by RS485
communication, change the host module DIP switch to 0110(
“
#2
”
&
“
#3
”
to
“
ON
”
) before
connecting.
(5)
If the battery communicates with the ICC by 485 communication, change the host module
DIP switch to 1001(
“
#1
”
&
“
#4
”
to
“
ON
”
) before connecting,
the DIP switch of the slave module should be changed to 0001(
“
#4
”
to
“
ON
”
) at the same time.
(6)
If PowerDepotH5 needs to be used with ICC,the DIP on the light PCB of the PowerDepot
must be changed to ON,as shown in the figure below.The DIP on the light PCB of the
PowerDepot shipped by default is in “OFF” state(500K).