B3 ESS Unit User Manual
17
The circuit breaker is installed between the battery module and the inverter, as shown in Figure
3-7:
No.1 No.2 No.3 No.4
Figure3-7
Note: If the inverter is one of GOODWE, Solis, LUX, Sofar, DEYE, VICTRON, IMEON, Voltronic,
Sungrow, RENAC and DELIOS the DIP switch mode of the host is shown in No.1.
If the inverter is one of Growatt, GMDE Saj, and AXPERT the DIP switch mode of the host is
shown in No.2.
If the battery module is in communication with the GROWATT-SPF-off-grid inverter by 485
communication, the DIP switch mode of the host is shown in No.3.
The DIP switch mode of the slave does not need to move, as shown in No.4.
Note: For more information of matching inverter brands, please subject to the latest document
<The list of compatibility between Dyness ESS and Inverters >.
Power cable-
negative
Power cable-
positive
Parallel cable-
positive
Parallel cable-
negative
Communication
cable-to inverter
Communication
parallel cable
Circuit
breaker
Inverter