![Dynaset HPW DUST 130 DOUBLE DUST User Manual Download Page 41](http://html1.mh-extra.com/html/dynaset/hpw-dust-130-double-dust/hpw-dust-130-double-dust_user-manual_2548781041.webp)
41
HIGH PRESSURE DUST SUPPRESSION
TECHNICAL SPECIFICATIONS
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | [email protected] | www.dynaset.com
10. TECHNICAL SPECIFICATIONS
HPW-DUST
200
HPW-DUST
200
DOUBLE
DUST
HPW-DUST
220
DOUBLE
DUST
HPW-DUST
180
DOUBLE
DUST
HPW-DUST
130
DOUBLE
DUST
WATER POWER
Basic flow
@ recommended
pressure
l/min
(gpm)
21
(5.5)
10
(2.6)
21
(5.5)
45
(11.9)
60
(15.9)
High Power flow
@ recommended
pressure
l/min
(gpm)
-
30
(7.9)
50
(13.2)
90
(23.8)
180
(47.6)
Pressure
recommended
bar
(psi)
140
(2000)
140
(2000)
140
(2000)
140
(2000)
130
(1900)
Pressure max
bar
(psi)
200
(2900)
200
(2900)
220
(3200)
180
(2600)
130
(1900)
Nozzle (basic)
pcs
4
2
4
4
6
High power nozzle
pcs
-
2
2
2
2
WATER INTAKE REQUIREMENTS
Recommended
suction hose size
in
3/4”
3/4”
1”
1 1/4”
2”
Suction filter flow
min
l/min
(gpm)
50
(13.2)
50
(13.2)
80
(21.1)
130
(34.3)
200
(52.8)
Recommended
filter mesh
80 or better
Suction head max
m (ft)
3 (9.8)
Feed pressure
bar (psi)
-0,3...16 (-43.5...232)
HYDRAULIC POWER REQUIREMENTS
Oil flow max.
l/min
(gpm)
40
(10.6)
40
(10.6)
70
(18.5)
115
(30.4)
140
(37.0)
Pressure max.
bar
(psi)
210
(3000)
210
(3000)
210
(3000)
210
(3000)
250
(3600)
HYDRAULIC CONNECTIONS
Pressure line
(female)
P
1/2"
1/2"
3/4”
3/4”
3/4”
Return line
(male)
T
1/2"
1/2"
3/4”
3/4”
3/4”
HYDRAULIC FLUID REQUIREMENTS
Viscocity
cSt
10-200 / optimum 25-35
Temperature
° C (° F)
max. 70
(160 )
Filter ratio,
recommendation
μm
25 or better
Cooling capacity
requirement
kW
2
2
3
6
6
Gallons are U.S. liquid gallons