Dynaset HEU 320-40E Manual Download Page 4

HYDRAULIC EXPANDING UNIT FOR ROCK-BOLTING

HEU 320-40E 

March 2011

SAFETY PRECAUTIONS

The pressure in both hydraulic and pumping fluid circuits is considerably high. There at the technical 

condition of your equipment should be under constant scrutiny. Especially couplings, valves and hoses 

should be maintained tight and clean as well as kept under constant observation.

Hydraulic leakages must be rectified immediately to avoid injuries caused by pressure and hot oil 

blowouts.

Follow all your local safety instructions related to the high pressure hydraulics.

Hydraulic system of a carrier machine should be maintained according to the service program. 

In order to exclude possible accidents, it is not allowed to clean or inspect HEU-pump when hydraulic 

or/and pumping fluid circuit is pressurized. Prior to any cleaning, inspection and service hydraulic 

system of your carrier machine must be stopped and both hydraulic and pumping fluid circuits 

dissipated.

Always wear appropriate clothing and safety equipment such as goggles, ear protection and safety 

shoes at all times when operating the HEU-unit.

When operating the tool, beware of machinery parts warmed by hot hydraulic oil.

Do not lift the tool by the water hose.

NEVER POINT THE EXPANDING GUN AT BYSTANDERS OR ANY INAPPROPRIATE OBJECT!

EXTERME CLEANLINESS MUST BE MAINTAINED WHEN CARRYING OUT ANY SERVICE DISSASSEMBLING 

OR REPAIR OF HRN-TOOL AND HYDRAULIC SYSTEM. THIS IS CRUCIAL TO ENSURE SAFE, RELIABLE 

AND LONG-LIFE OPERATION OF YOUR EQUIPMENT.

Operators and maintenance personnel must always comply with local safety regulations and precautions 

in order to close out the possibility of damages and accidents.

All installation and service of both hydraulic and electric equipment must be performed by qualified 

and experienced personnel only.

PUMPING FLUIDS

Water based fluids and sea water can be pumped without any special arrangements, however the 

HRN-tool MUST BE FLUSHED AND CLEANED THOROUGHLY after a working shifts with clean sweet water. 

Same rule applies to pumping of gelatin and depositing fluids —after having done your job, flush 

HRN-tool with clean water or suitable solvent. 

Solvents, fuels and oils can be pumped without any special arrangements. 

Fluids with abrasives or high content of solids can be pumped as well, but should be kept in mind, that 

HRN-tool’s service life time is considerably shortened.

Furthermore, if pumping solution is aggressive to NBR-rubber, special seals and hoses must be used.

WARRANTY

DYNASET products are warranted against defects in materials and workmanship for a period of 12 
(twelve) months from the date of purchase. Exceptions are parts subject to normal wear and tear, such 
as seals and other parts that become worn through normal use of the unit.
Warranty covers detective parts solely. Expenditure incidental to shipping and replacement are not 
covered by present warranty.
The warranty is void if product has been modified, provided with parts other than original or misused.

4 / 5

Reviews: