HomePNA Switch Installation and Setup Manual
18
13. AUTO RESET
The auto reset function enables the HomePNA Switch to automatically
reset the switch & ports or the whole unit periodically. By default, Auto Reset
function is off, to enable Auto Reset simple issue the “RSP” command on the
ICD command interface.
Example 1:
Set unit to auto reset switch and ports every 8 hours
RSP S,8
Example 2:
Set unit to reboot unit every 8 hours
RSP U,8
Example 3:
Turn off Auto Reset
RSP F
You may view the Auto Reset status in the Unit Information through the “U”
command at ICD Command Interface. When the unit is restored to its factory
defaults using the RSW command, Auto Reset is off.
14. HIGH/LOW POWER MODE
The HomePNA Switch contains two power modes for transmission:
low power, and high power. This setting was integrated within the switch for
installations that contain some long distance HomePNA port installations of
500 ft and 1000 ft. Power modes are adjustable on a per port basis, but with
the following side effects:
I.
High Power Mode will cause much more Cross Talk within the line of
the port modified.
II.
Data Rate may be slightly affected by raising the power mode, resulting
in slower transmission.
The command to change the power mode must be obtained from your
vendor.