![Dynamic DX-ECU Installation Manual Download Page 10](http://html1.mh-extra.com/html/dynamic/dx-ecu/dx-ecu_installation-manual_2548050010.webp)
GBK64227 - Issue 3 : August 1998
© Copyright Dynamic Controls Ltd. 1998
8
Molex Connector
A maximum of two ECU Modules can be connected into any DX system. These are
nominally labelled ECU1 and ECU2. In order for the SCR to determine which
Module is ECU1 or ECU2, the Molex socket is used.
Supplied with the ECU is a Molex plug which, when fitted into the Molex socket,
will effectively tell the SCR that it is ECU2.
When the DX System is powered up, the ECU(s) is designated an ID (ECU1 or 2
depending whether the Molex plug is inserted) and the relevant LED is lit.
Note :
Care should be taken when looming for the ECU and other DX
modules that wires can not be transposed.