8
Mechanical Unit Model Numbers
Velocity
Damping
Setting
AC/ACW/ACS/PD/VT
Fractional Hp (FHP)
AS/AT/AE/VT/EC
Fractional Hp
14/112/140
0%
181/182/184/186
18/21/132/160/180/210
50%
214/216/254/256
25/27/180/225/250/280
75%
280/320/360/440
320/360/440
75%
Mechanical Unit Model Numbers
TC Adjust
Setting
AC/ACW/ACS/PD/VT Fractional
Hp (FHP)
AS/AT/AE/VT/EC
FHP/181/182
0%
184/186/214
14/18/112/132/140/180
15%
216/254/256/280
21/160/210
30%
320/360/440
25/24/180/225/250/280
320/360/440
100%
*Typical product number stamped on mechanical unit nameplate:
1. A1-100214-0053, specific mechanical model is AC-214
2. B2-100210-0008, specific mechanical model is AS-21
Trimpot Illustration:
3.
Torque Limit
Mod PCB 15-444-2
a.
Set the Torque Limit Damping potentiometer R18 at 50% CW
b.
Set the Torque Limit potentiometer R19 at 50% CW (this setting is approximately 150% of
rated motor torque)
c.
Set HI Damping potentiometer R20 to 0% (Full CCW)
Summary of Contents for 15-533-1015
Page 3: ...3 Connection diagram for Standard Enclosure 4000 Controller ED 58215 ...
Page 4: ...4 Schematic Diagram for 4000 Controller ...
Page 5: ...5 Connection Diagram for 4000 Panel Mount and 4050 Controllers ED 56815 ...
Page 6: ...6 Schematic Diagram for 4050 Controller Torque Limit Modification PCB 15 444 2 ...