There are two knobs and one main switch on the front panel of the analog types of the 
mixers.  The main switch has three stages function:  

ON, OFF and Timer

.  For continuous 

operation, place the switch to the “

ON

” position, and turn the rpm knob (on the right hand 

side) to desired speed.  When using timer, place the switch to “

Timer

” position, and adjust 

the speed using speed knob.  

Before turning on the machine, please turn the speed knob all 

the way to the left hand side (minimum level)!

  And adjust the speed gradually. 

3.  The temperature setting of the mixer incubator (*MI series) 

The mixer incubators have two separate control panels:  The bottom panel is for the control 
of speed and timing which is exactly the same setting procedures describe above; and the 
top control panel is for temperature control (see Figure 16).  To set the temperature, hold 
the set button, and turn the knob to the desired temperature.  After release the set button, 
the temperature setting takes in effect immediately.  For CMI-100, the temperature can only 
be set from 5˚C above room temperature to 60 ˚C maximum. 

 

 

Maintenance and Service 

This range of equipment only requires routine cleaning for the maintenance.  Before 
cleaning,   

Always unplug the equipment from the electrical outlet.

  Use soft cloth with mild 

detergent to clean the surface of the equipment. 

 

 

 

 

 

 

 

 

Dynalab Corp. |  175 Humboldt Street, Suite 300  |  Rochester, NY 14610 

Tel: 800-334-7585  | Fax: 585-334-0241 

www.dynalon.com

  |  E: 

[email protected]

 

Summary of Contents for DGRL-01-01

Page 1: ...1 Rockers DGRL DGRM DSRL DSRM series OPERATING MANUAL Dynalab Corp November 2017 DGRL 01 01 DGRM 01 02 ...

Page 2: ...2 BEFORE USE Please read the following instructions Warning Check the line supply is sufficient to meet the power requirement of the unit ...

Page 3: ...OR ANY DAMAGE OF AN INDIRECT OR CONSEQUENTIAL NATURE ARISING OUT OF OR RELATED TO ITS PERFORMANCE WHETNER BASED UPON BREACH OF AGREEMENT WARRANTY OR NEGLIGENCE AND WHETHER GROUNDED IN TORT CONTRACT CIVIL LAW OR OTHER THEORIES OF LIABILITY INCLUDING STRICT LIABILITY EVEN IF ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES THE COMPANY S TOTAL LIABILITY INCLUDING BUT NOT LIMITED TO LIABILITY FOR...

Page 4: ...ation type and the wave type With tilted angle in one end the gyration mixers gyrate in three dimension This mixing action is suitable for full flashing some floated object by liquid such as staining and de staining gels and low foaming mixing purpose The wave type is based on see saw action to create wave like mixing of the liquid and suitable for Petri dish and culture fl ...

Page 5: ...he mini scale 3D gyrator rocker RCK 31 Electrical socket Slip proof platform LED display on Digital front panel Figure 5 Overview of the lab scale see saw rocker RCK 21 Electrical socket Slip proof platform Digital front panel ...

Page 6: ...the minimum rpm And examine the nut underneath the center cylinder shaft turning front then stop the machines and tilt the platform to desired angle Figure 13 Overview of head box Load the samples first before turning on the machine Be aware of loading sample evenly and never overload the samples Always start with low speed and gradually adjust the speed especially for the analog model There are t...

Page 7: ...uminate turn the knob to desired count down minute To disable the timer just turn the knob to the unit will continuously operate until manually stopping the unit When the timer reaches to zero the unit stops and sounds an alert The default time unit is minute displayed nnnn but it can be changed to Hour Minute displayed H nn or Minute Second displayed nn ss To do so turn off the machine completely...

Page 8: ...ttom panel is for the control of speed and timing which is exactly the same setting procedures describe above and the top control panel is for temperature control see Figure 16 To set the temperature hold the set button and turn the knob to the desired temperature After release the set button the temperature setting takes in effect immediately For CMI 100 the temperature can only be set from 5 C a...

Reviews: