background image

X-Amps

First of all, we would like to take the opportunity to thank you for and congratulate you on buying the
DYNACORD X-Amp Series power amplifiers.

X-Amps - a modular power amplifier concept and the most flexible solution for any mobile and permanent
installation application. The modular architecture of the X-Amps allows flexible selection of filter / signal
processor as well as input and output modules. This provides the possibility to easily include X-Amps
power amplifiers into basically any existing and most of all any future application, using principally any
connection technique. Factory-shipped, the X-Amps are equipped with an input module Xi-11 (XLR-type
inputs with thru-connectors) and an output module Xo-1 (SPEAKON-type connectors). The front slots of
the X-Amps are covered with blind panels. These slots are meant for including filter or signal processor
modules into the signal path. Next to generic modules for general use, cabinet-pertinent modules for
DYNACORD V-Systems loudspeakers are available, which in regard to their response and dynamic
capacity optimally match the equalization of the V-Systems loudspeaker components.

The use of front modules makes it easy to establish high quality and yet cost effective multi-way systems
while cabling of the entire system is drastically reduced.

The power amplifiers X1201 providing 1 x 1200W into 4 ohms and X1202 providing 2 x 600W into 4 ohms
unite outstanding audio performance, highest reliability, and security.

The gapless protection concept not only prevents the power amplifiers from being damaged but also the
connected loudspeaker systems. This extensive protection circuitry includes dynamic  limiters, DC/HF
protection, Back-EMF protection, inrush current limiter, short circuit protection, thermal brain circuit, and
of course the protection against thermal overload of the power stage transistors and the transformers.
During “soft start”, delayed switching the power outputs is performed via relays.

Thermal stability is guaranteed through extremely low-noise, 3-stage fans.

The air circulation is front-to-rear, allowing trouble-free operation even in smaller power amplifier rack
systems.

The embodied comparators constantly monitor the power amp’s input and output signals, and control the
integrated limiters whenever non-linearity is detected, thus protecting the connected loudspeaker systems
against overload and power amplifier clipping. The overall response of the X-Amps is simply extraordinary.
Using widely dimensioned power supplies with low-loss toroidal transformers provide additional headroom
way above the stated nominal power output capacity. The power amplifiers do not employ V/I-Foldback-
Limiters, which allows to drive even complex loads with phase angles of up to 90° without a problem.

Also the mechanic construction and manufacturing guarantee highest precision. The robust and highly
rigid steel chassis is meant to survive the extensive wear of touring applications. The easily readable
LED-display provides quick information about the power amplifier’s operational state. Ready-mode, signal
presence, and the activation of limiters or of one of the protection functions are indicated for both channels
individually. All X-Amp Series power amplifiers are capable of handling loads down to 2 ohms.

This owner’s manual holds information about many other features of the X-Amp Series power amplifiers.
Therefore, carefully reading the entire manual is strongly recommended, so that you are able to get the
best performance from your new DYNACORD X-Amp Series power amplifier.

C O N T E N T S

Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13

X-Amp System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17

Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  18
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  32
Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  34
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  36
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

D E S C R I P T I O N

13

Summary of Contents for X 1202

Page 1: ...X1201 X 1202 MODULAR POWER AMPLIFIER OWNER S MANUAL...

Page 2: ...into your outlet consult an electrican for replacement of the absolete outlet 1 Security regulations as stated in the EN 60065 VDE 0860 IEC 65 and the CSA E65 94 have to be obeyed when servicing the a...

Page 3: ...thermal brain circuit and of course the protection against thermal overload of the power stage transistors and the transformers During soft start delayed switching the power outputs is performed via...

Page 4: ...amplifier allow the insertion of Xm filter and signal processor modules A wide range of modules with individual functions are available In this way it is possible to integrate the signal processing wh...

Page 5: ...which in response and dynamic capacity optimally match the corresponding loudspeaker system Thus it is extremely easy to create optimally tuned high quality multi way systems that are truly unique in...

Page 6: ...load e g at extreme high environmental temperatures in a rack shelf system insufficient ventilation and extreme long lasting continuous operation with 2 ohms loads connected Inrush Current Limiter lim...

Page 7: ...case in permanent installation applications to provide additional cooling employing an external rack cooling system Sufficient air circulation has to be guaranteed at all times Mains power When shipp...

Page 8: ...are inserted or exchanged disconnecting the mains plug is absolutely mandatory The front module is simply inserted into the slot and locked in place The functions of signal processing modules are auto...

Page 9: ...gets damaged from mains peaks This also prevents that the mains fuse blows when the power amplifier is switched on The loudspeaker power outputs are delayed switched by approx 2 seconds via relays so...

Page 10: ...tors The inputs of the power amplifier are electronically balanced The pin assignment is according to the IEC standard 268 Input transformers can be retrofitted With the Xi 11 input module inserted th...

Page 11: ...from the ground potential which helps in preventing hum loops Hum loops result from several devices being connected to a mutual ground potential via mains plugs and at the same time when installed in...

Page 12: ...er 0 05 MBW 80kHz 1kHz IMD SMPTE 0 08 60Hz 7kHz DIM30 0 03 3 15kHz 15kHz Frequency Response 13 Hz 45 kHz 1dB ref 1kHz Power Bandwith 10 Hz 50 kHz THD 1 ref 1kHz half power 4 ohms Input Impedance 20 ko...

Page 13: ...ower 0 05 MBW 80kHz 1kHz IMD SMPTE 0 08 60Hz 7kHz DIM30 0 03 3 15kHz 15kHz Crosstalk Attenuation 80 dB ref 1kHz at rated output power Frequency Response 13 Hz 45 kHz 1dB ref 1kHz Power Bandwith 10 Hz...

Page 14: ...BLOCK DIAGRAM 34...

Page 15: ...BLOCK DIAGRAM 35...

Page 16: ...Abmessungen Dimensions in mm X 1201 X 1202 ABMESSUNGEN DIMENSIONS 36...

Page 17: ...ct The warranty does not cover damage that results from improper or inadequate treat ment or maintenance In case of alteration or unauthorized repairs the warranty is automatically termi nated GARANTI...