background image

2

3

The lightning flash with arrowhead symbol, within an 
equilateral triangle is intended to alert the user to the 
presence of uninsulated „dangerous voltage“ within 
the  product’s  enclosure  that  may  be  of  sufficient 
magnitude  to  constitute  a  risk  of  electric  shock  to 
persons

The exclamation point within an equilateral triangle is 
intended to alert the user to the presence of important 
operating and maintance (servicing) instructions in 
the literature accompanying the appliance.

1.  

Read these instructions.

2. 

Keep these instructions. 

3.  

Heed all warnings.

4. 

Follow all instructions.

5.  

Do not use this apparatus near water. 

6. 

Clean only with a dry cloth.

7.  

Do not block any ventilation openings. Install in accordance with the manufacturers instructions.

8. 

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus 

 

(including amplifiers) that produce heat.

9. 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades    

 

with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide    

 

blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an  

 

electrican for replacement of the obsolete outlet.

10. 

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles,  

 

 

and the point where they exit from the apparatus. 

11. 

Only use attachments/accessories specified by the manufacturer.

12. 

Unplug this apparatus during lightning storms or when unused for long periods of time.

13.  

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been 

 

damaged in any  way, such as power-supply cord or plug is damaged, liquid has been spilled or 

 

objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not

 

operate normally, or has been dropped

14. 

To completely disconnect mains power from this apparatus, the power supply cord must be 

 

unplugged.

15. 

Do not expose this apparatus to dripping or splashing and ensure that no objects filled with liquids, such as    

 

vases, are placed on this apparatus. 

16. 

The mains plug of the power supply cord shall remain readily operable.

CAUTION:  

These  servicing  instructions  are  for  use  by  qualified  personnel  only.  To  reduce 

   

 

the  risk  of  electric  shock,  do  not  perform  any  servicing  other  than  that  ontained 

  

 

in  the  Operating  Instructions  unless  you  are  qualified  to  do  so.  Refer  all  servicing 

  

 

to qualified service personnel.

1. 

Security regulations as stated in the EN 60065 (VDE 0860 / IEC 65) and the CSA E65 - 94 have to be obeyed when 

 

servicing the appliance

2. 

Use of a mains separator transformer is mandatory during maintenance while the appliance is opened, needs to be  

 

operated and is connected to the mains

3. 

Switch off the power before retrofitting any extensions, changing the mains voltage or the output voltage.

4. 

The minimum distance between parts carrying mains voltage and any accessible metal piece (metal enclosure),  

 

respectively between the mains poles has to be 3 mm and needs to be minded at all times. The minimum distance  

 

between parts carrying mains voltage and any switches or breakers that are not connected  to the mains (secondary  

 

parts) has to be 6 mm and needs to be minded at all times.

5. 

Replacing special components that are marked in the circuit diagram using the security symbol (Note) is only  

 

permissible when using original parts.

6. 

Altering the circuitry without prior consent or advice is not legitimate.

7. 

Any work security regulations that are applicable at the location where the appliance is being serviced have to be  

 

strictly obeyed. This applies also to any regulations about the work place itself.

8. 

All instructions concerning the handling of MOS - circuits have to be observed. 

SAFETY COMPONENT ( MUST BE REPLACED BY ORIGINAL PART )

NOTE:

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SERVICE INSTRUCTIONS

 

Caution:    Do not exceed the marked rating of the Mains Output. 

 

Example:   If each additional unit is rated 3A, a maximum of 3 units can be connected for a total of 9A.

Summary of Contents for Madras M 212

Page 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG ...

Page 2: ...LTER 6 NETZEINGANG 6 SPECIFICATIONS TECHNISCHE DATEN 13 DIMENSIONS ABMESSUNGEN 14 BLOCK DIAGRAM 15 INHALT WICHTIGE SICHERHEITSHINWEISE 9 WICHTIGE SERVICEHINWEISE 9 BESCHREIBUNG 10 AUSPACKEN GARANTIE 10 BEDIENELEMENTE 11 INPUT OUTPUT 11 LEVEL 11 MODE 11 STATUS ANZEIGEN 12 POWER SCHALTER 12 NETZEINGANG 12 SPECIFICATIONS TECHNISCHE DATEN 13 DIMENSIONS ABMESSUNGEN 14 BLOCK DIAGRAM 15 ...

Page 3: ...ains power from this apparatus the power supply cord must be unplugged 15 Do not expose this apparatus to dripping or splashing and ensure that no objects filled with liquids such as vases are placed on this apparatus 16 The mains plug of the power supply cord shall remain readily operable CAUTION These servicing instructions are for use by qualified personnel only To reduce the risk of electric s...

Page 4: ...tal and vertical radiation characteristics are outstandingly smooth which makes the MADRAS M212 resistant against acoustical feedback and therefore especially suitable for high power monitoring applications The fully electronic THERMAL PROTECTION prevents the transducers from being damaged by thermal overload That s what makes the MADRAS M212 equally suitable for a wide range of demanding applicat...

Page 5: ... of pre linked mixing consoles the control should generally be set to a value between 0dB and 6dB MODE This switch allows selecting the operation mode of the M212 The cabinet s internal active frequency crossover is automatically deactivated when set to FULLRANGE The loudspeaker system transmits the entire frequency range Setting the switch to the position MID HIGH activates an active frequency cr...

Page 6: ...e working POWER switch Mains switch for powering the appliance on or off With the power amplifier being switched on the mains switch is backlit If after switching the power on the switch is not backlit please first check whether the mains cord is correctly connected In case the cord has been connected correctly and the switch still fails to light no function please contact your specialist dealer M...

Page 7: ...BEDIENUNGSANLEITUNG ...

Page 8: ...CHTIGE SERVICEHINWEISE 9 BESCHREIBUNG 10 AUSPACKEN GARANTIE 10 BEDIENELEMENTE 11 INPUT OUTPUT 11 LEVEL 11 MODE 11 STATUS ANZEIGEN 12 POWER SCHALTER 12 NETZEINGANG 12 SPECIFICATIONS TECHNISCHE DATEN 13 DIMENSIONS ABMESSUNGEN 14 BLOCK DIAGRAM 15 ...

Page 9: ...en WICHTIGE SERVICEHINWEISE ACHTUNG Diese Servicehinweise sind ausschliesslich zur Verwendung durch qualifiziertes Servicepersonal Um die Gefahr eines elektrischen Schlages zu vermeiden führen Sie keine Wartungsarbeiten durch dienichtinderBedienungsanleitungbeschriebensind ausserSiesindhierfürqualifiziert Überlassen Sie sämtliche Servicearbeiten und Reparaturen einem ausgebildeten Kundendiensttech...

Page 10: ...g der MADRAS M 212 ist extrem linear Die horizontale und vertikale Abstrahlcharakte ristik ist ausserordentlich gleichmässig die MADRAS M 212 ist deshalb sehr rückkopplungsarm und insbesondere auch für High Power Monitoranwendungen optimal geeignet Die vollelektronische THERMAL PROTECTION schützt die Transducer vor thermischer Überlastung Die MADRAS M 212 eignet sich deshalb auch besonders für vie...

Page 11: ...on Verzerrungen in vorgeschalteten Mischpulten sollte dieser Regler normalerweise zwischen 0dB und 6dB eingestellt werden MODE Mit diesem Schalter wird die Betriebsart der M212 einge stellt In Stellung FULLRANGE ist die eingebaute aktive Frequenzweiche ausgeschaltet und die Box überträgt den gesamten Frequenzbereich In Stellung MID HIGH wird eine aktive Frequenzweiche mit 124Hz Übergangsfrequenz e...

Page 12: ...iviert sind POWER Schalter Netzschalter zum Ein und Ausschalten des Gerätes Der Netz schalter ist beleuchtet wenn das Gerät eingeschaltet ist Sollte der Schalter nach dem Einschalten nicht leuchten prüfen Sie zuerst ob das Netzkabel angesteckt ist Ist dies der Fall und trotzdem keine Funktion vorhanden kontaktieren Sie bitte ihren Fachhändler MAINS FUSE Die Netzsicherung des Gerätes löst unter nor...

Page 13: ... 430 x 800 x 432 mm Weight 42 kg Power Amplifier Inputs and Crossover Specifications Max Dynamic Output Power IHF A LO 540W HI 160W Max Continuous Output Power LO THD 1 400Hz 460W HI THD 1 4kHz 140W Power Amplifier Design High Efficiency Class H THD N rated 0 01 Input Impedance balanced 20kohms Level Control oo 6dB Crossover Mode Switch FULLRANGE 12dB Octave BU 124Hz MID HIGH 24dB Octave LR 124Hz ...

Page 14: ...14 DIMENSIONS ABMESSUNGEN ...

Page 15: ...15 BLOCKDIAGRAM ...

Page 16: ...rnsville MN 55337 Phone 1 952 884 4051 FAX 1 952 884 0043 Germany EVI AUDIO GmbH Hirschberger Ring 45 D 94315 Straubing Germany Phone 49 9421 706 0 FAX 49 9421 706 265 Subject to change without prior notice Printed in Germany 10 02 2004 363 476 www dynacord de ...