Dynabrade Dynorbital-Spirit 21000 Operation And Maintenance Manual Download Page 3

Maintenance Instructions

Important:

A Preventative Maintenance Program is recommended whenever portable power tools are used.

Use only genuine Dynabrade replacement parts to insure quality. To order replacement parts, specify 

Model#

Serial#

and 

RPM

of your air tool.

It is strongly recommended that all Dynabrade rotary vane air tools be used with a Filter-Regulator-Lubricator to minimize the possibility of misuse due
to unclean air, wet air or insufficient lubrication. Dynabrade recommends the following: 

11405

Air Filter-Regulator-Lubricator (FRL) – Provides accurate

air pressure regulation and two stage filtration of water contaminates. Operates 40 SCFM/1,133 LPM @ 100 PSIG with 3/8" NPT female ports.

Dynabrade recommends one drop of air lube per minute for each 20 SCFM (example: if the tool specification states 40 SCFM, set the drip rate on the 
filter-lubricator to 2 drops per minute). Dynabrade Air Lube (P/N 

95842

: 1 pt 473 ml) is recommended.

Routine Preventative Maintenance: 

Check free speed of Dynorbital-Spirit

®

using a tachometer.

Mineral spirits are recommended when cleaning the tool and parts. Do not clean tool or parts with any solvents or oils containing acids, esters, 
ketones, chlorinated hydrocarbons or nitro carbons.

DO NOT clean or maintain tools with chemicals that have a low flash point (example: WD-40

®

).

A Drop-In Motor and Tune-Up Kit are available, see specific kit number on page 9.

Air tool stampings must be kept legible at all times, if not, reorder and replace. User is responsible for maintaining specification information i.e.:
Model #, S/N, and RPM.

Blow air supply hose out prior to initial use.

Visually inspect air hoses and fittings for frays, visible damage and signs of deterioration. Replace damaged or worn components.

Refer to Dynabrade's Warning/Safety Operating Instructions Tag (Reorder No. 

95903

) for safety information.

After maintenance is performed on tool, add a few drops of Dynabrade Air Lube (P/N 

95842

) to the air line and start the tool a few times to lubricate air motor. 

Check for excessive tool vibration.

Handling and Storage:

Protect tool inlet from debris (See Notice Below).

DO NOT carry tool by air hose.

Protect abrasive accessories from exposure to water, solvents, high humidity, freezing temperature and extreme temperature changes.

Store accessories in protective racks or compartments to prevent damage.

Notice

All Dynabrade motors use the highest quality parts and materials available and are machined to exacting tolerances. The failure of quality pneumatic motors
can most often be traced to an unclean air supply or the lack of lubrication. Air pressure easily forces dirt or water contained in the air supply into motor
bearings causing early failure. It often scores the cylinder walls and the rotor blades resulting in limited efficiency and power. Our warranty obligation is
contingent upon proper use of our tools and cannot apply to equipment which has been subjected to misuse such as unclean air, wet air or a lack of
lubrication during the use of this tool.

One Year Warranty

Following the reasonable assumption that any inherent defect which might
prevail in a product will become apparent to the user within one year from
the date of purchase, all equipment of our manufacture is warranted
against defects in workmanship and materials under normal use and
service. We shall repair or replace at our factory, any equipment or part
thereof which shall, within one year after delivery to the original purchaser,
indicate upon our examination to have been defective. Our obligation is
contingent upon proper use of Dynabrade tools in accordance with factory
recommendations, instructions and safety practices. It shall not apply to
equipment which has been subject to misuse, negligence, accident or
tampering in any way so as to affect its normal performance. Normally
wearable parts such as bearings, contact wheels, rotor blades, etc., are not
covered under this warranty.

3

1. American National Standards Institute – ANSI

25 West 43

rd

Street

Forth Floor
New York, NY 10036
Tel: 1 (212) 642-4900
Fax: 1 (212) 398-0023

3. European Committee for Standardization

Rue de Stassart 36
B - 1050 Brussels, Belgium

2. Government Printing Office – GPO

Superintendent of Documents
Attn. New Orders
P.O. Box 371954
Pittsburgh, PA 15250-7954
Tel: 1 (202) 512-1803

Reference Contact Information

Summary of Contents for Dynorbital-Spirit 21000

Page 1: ...arts to reduce risk of injury to operator visitors and tool WARNING Eye protection must be worn at all times eye protection to conform to ANSI Z87 1 WARNING Respiratory protection to be used when expo...

Page 2: ...ting instructions With power source disconnected from air tool mount recommended accessory into collet assembly Connect air tool to power source Be careful NOT to depress throttle lever in the process...

Page 3: ...orage Protect tool inlet from debris See Notice Below DO NOT carry tool by air hose Protect abrasive accessories from exposure to water solvents high humidity freezing temperature and extreme temperat...

Page 4: ...21016 21019 21020 21021 21024 21025 21026 21029 21030 21031 21034 21035 21036 21039 21040 21041 21044 21045 21046 21049 21050 21051 21054 21055 21056 21059 21060 21061 21062 21063 21064 21065 18 26 29...

Page 5: ...ough the central vacuum adapter 3 Place muffler cap with inserts on muffler body making sure that the protrusions on the body fit in the pockets on the cap 4 Attach weight mated vacuum sanding pad wit...

Page 6: ...cured in a vise use the 57092 Repair Collar of padding on the jaws of the vise to protect the housing slide the drop in air motor into the housing aligning the line up post with the notch on the insid...

Page 7: ...g the slider weight pull the assembly out c Press off 56052 Bearing with a bearing separator and arbor press remove 59084 V Seal 12 If during step 11 the 56052 Bearing remains in the motor shaft balan...

Page 8: ...9 O Ring on the valve stem Then place in housing with valve stem Install new 95967 Snap Ring Apply a small amount of pneumatic tool oil to valve o rings 5 Place new 01464 Seal in housing Using tweezer...

Page 9: ...8 56027 Muffler Inserts 2 T 9 56028 Muffler Cap 1 T Drop in Motors Allows a quick and easy replacement No motor adjustments needed 59450 3 3 1 2 Dia 3 8 Orbit 59451 3 3 1 2 Dia 3 16 Orbit 59452 3 3 1...

Page 10: ...excellent disc adhesion allowing for quick removal of used discs Special rubber vinyl face pads for PSA discs Post Pattern design for enhanced vacuum pick up Unique vinyl surface pads provide excellen...

Page 11: ...ng cloth cover Covers air line and exhaust vacuum hoses not included Eliminates damage from hoses dragging on the workpiece 54290 Bag in Box System 95361 Air Line 5 long 50682 Flex Hose 1 dia x 6 long...

Page 12: ...3 90 6 2 5 16 24 female 1 4 0 6 7 178 3 1 2 89 21025 25 186 12 000 3 16 5 80 dB A 16 453 90 6 2 5 16 24 female 1 4 0 6 6 152 3 1 2 89 21026 25 186 12 000 3 16 5 84 dB A 16 453 90 6 2 5 16 24 female 1...

Reviews: