MAINTENANCE INSTRUCTIONS

1. Before beginning maintenance on the 21" Metalworking Station, you

must first unplug the GFI outlet from your main power source.
Continue by unplugging any accessory and remove the work surface
from the assembly. Also make sure to turn the reservoir valve to the
“OFF” position.

2. Remove and set aside the upper access panel by loosening all four

lock down knobs a full 2-3 full turns. Continue by turning the release
cam and remove the filter access panel. Remove the filter and hose
clean to remove any built up debris.

3. Now remove the float assembly by loosening the lock down knob.

The float assembly should remain attached to all hose and just rest
assembly over the tools edge as shown below. This should give you
clear access to the main tank.

4. Making sure clean out valve is in the “OFF” position, remove the cap

from the assembly. The valve provided hooks up to a female garden
hose for ease of clean out. Turn valve lever to the “ON” position and
drain tank. Remove the sludge and remainder of water from the
bottom of the tank, making sure not to damage the acrylic tank while
doing so. When tank is clean, turn valve back to the "off" position and
re-cap assembly.

Re-assemble tool and refer to set-up instructions before operating the tool.

(2) 

UPPER ACCESS PANEL

FILTER ACCESS PANEL
RELEASE KNOB

FILTER ACCESS PANEL

UPPER ACCESS PANEL
LOCK DOWN KNOB

(Four knobs total)

(1) 

WORK SURFACE REMOVED

(2) 

FILTER

SLUDGE AT BOTTOM
OF TANK TO BE
REMOVED AFTER
WATER IS DRAINED

(4) 

CLEAN OUT VALVE

(Shown in "ON" Position)

(4) 

VALVE CAP

(3) 

FLOAT ASSEMBLY

MOVED FOR CLEANING 
MAIN TANK

FLOAT ASSEMBLY
LOCKING KNOB

Buy parts on line at https://Dynashop.co.uk/ for all things Dynabrade

Buy parts on line at https://Dynashop.co.uk/ for all things Dynabrade

Summary of Contents for 64100

Page 1: ...PD06 31 IMPORTANT SAFETY INSTRUCTIONS SAFETY LEGEND Keep workplace area free of contaminants while deburring When operating this equipment basic precautions should always be strictly followed including the instructions listed below 21 Metalworking Station Operating Manual WARNING Read and understand tool manual before work starts to reduce risk of injury to operator visitors and tool WARNING Eye p...

Page 2: ...t switch GFI POWER SUPPLY UPPER ACCESS PANEL DEBRIS SHIELD FILTER ACCESS PANEL REMOVABLE WORK SURFACE WATER LEVEL WINDOW CLEAN OUT VALVE FLOAT ASSEMBLY MAIN TANK RESERVOIR CONTROL VALVE RESERVOIR 2 Buy parts on line at https Dynashop co uk for all things Dynabrade Buy parts on line at https Dynashop co uk for all things Dynabrade ...

Page 3: ...n 3 The next step is to add water to your station Fill the main acrylic tank A with water until you reach the line that indicates the proper level in the Power off position Continue by adding water to the reservoir B approximately 3 4 to the top 4 Switch reservoir valve to Float position 5 Plug in the 21 Metalworking Station Be sure to push the reset button on the GFI plug before turning system on...

Page 4: ... Seal 46 64163 Seal 47 64120 Support Bracket 48 64147 Edge Trim 49 64149 Edge Trim 50 64150 Edge Trim 51 64152 Neoprene Strip 52 64153 Neoprene Strip 53 64154 Neoprene Strip 54 64155 Neoprene Strip 55 64156 Neoprene Strip 56 64157 Neoprene Strip 57 64158 Tubing 58 64160 Work Surface Assembly 59 64159 Tubing 60 64161 Tubing 61 64145 Seal 62 64162 Water Level Label 63 98598 Nut 64 64164 Locking Cam ...

Page 5: ... 77 80 49 84 19 15 16 43 31 31 14 42 56 55 54 93 53 52 44 59 57 51 60 68 69 29 5 48 25 11 2 33 23 31 6 10 32 45 46 9 20 21 82 86 70 66 65 67 72 71 69 13 7 61 5 89 88 90 87 88 57 92 89 87 91 Buy parts on line at https Dynashop co uk for all things Dynabrade Buy parts on line at https Dynashop co uk for all things Dynabrade ...

Page 6: ...oir to make up for evaporation Turn power off after extended operation Min 4 Hours and re check initial Power off water level If low carefully bend the brass rod on the float assembly to move float body up approximately 1 16 If Power off water level is high bend the brass rod on the float assembly to move the float body down approximately 1 16 Re check again after extended operation 2 POWER SWITCH...

Page 7: ... to the main tank 4 Making sure clean out valve is in the OFF position remove the cap from the assembly The valve provided hooks up to a female garden hose for ease of clean out Turn valve lever to the ON position and drain tank Remove the sludge and remainder of water from the bottom of the tank making sure not to damage the acrylic tank while doing so When tank is clean turn valve back to the of...

Page 8: ...00 344 1488 DYNABRADE EUROPE S à r l Zone Artisanale L 5485 Wormeldange Haut Luxembourg Phone 352 768 494 1 Fax 352 768 495 DYNABRADE DO BRASIL Rua Mário Fongaro 421 Vila Marlene São Bernardo do Campo SP CEP 09732 530 Telefax 11 4124 6040 MACHINE SPECIFICATIONS Model Weight Width Depth Height Number Voltage Phase Frequency Pound kg Inch mm Inch mm Inch mm 64100 120 1 60 Hz 110 50 21 533 20 508 36 ...

Reviews: