Dynabrade 10671 Operating Instructions Manual Download Page 6

F.R.L. Unit Precautions 2

Be sure to read before handling

Mounting

Caution

1. To avoid reversed connections of the air inlet/outlet, make

connections after confirming the “IN/OUT” mark or arrows that
indicate the direction of air flow. Reversed connections can cause
malfunction.

2. Components with a bowl, e.g., air filter, filter regulator, lubricator,

must be installed vertically with the bowl downward so that faulty
drain discharge and dripping can be verified.

3. Ensure sufficient top, bottom, and front clearance for maintenance

and operation of each component. Refer to the dimensions section
for the minimum clearance for each component.

4.

Regulator and filter regulator

Be sure to unlock the knob before adjusting the pressure and to
lock it after the pressure is set.

Adjustment

Warning

1.

Regulator and filter 

regulator

a. Set the regulator while verifying the displayed values of the inlet

and outlet pressure gauges. Turning the knob excessively can
cause damage to the internal parts.

b. Do not use a tool on the pressure regulator knob as this can

cause damage. It must be operated manually.

Caution

1.

Regulator and filter regulator

a. Be sure to check the inlet pressure before setting the outlet

pressure.

b. To set the pressure using the knob, turn the knob in the

direction that increases pressure and lock the knob after the
pressure is set. If this is done in the direction that decreases
pressure, the pressure may drop from the original set pressure.
Turning the knob clockwise increases the outlet pressure, and
turning it counterclockwise reduces the pressure.

Piping

Warning

1. To screw piping materials into components, tighten with a

recommended tightening torque while holding the female thread
side. If the minimum tightening torque is not observed, this can
cause a looseness and seal failure. On the other hand, excess
tightening torque can cause damage to the threads. Furthermore,
tightening without holding the female thread side can cause
damage due to the excess force that is applied directly to the
piping bracket.

Recommended tightening torque

Unit: lb.- ft.

Connection Thread

3/8"

1/2"

Torque

16.2 to 17.7

20.6 to 22.1

* Alternatively tighten by hand, then tighten further approximately 1/6

turn using a tightening tool.

2. Avoid excessive torsional moment or bending moment other than

those caused by the equipmentʼs own weight as this can cause
damage. Support external piping separately.

3. Piping materials without flexibility such as steel tube piping are

prone to be affected by excess moment load and vibration from the
piping side. Use flexible tubing in between to avoid such an effect.

6

Buy parts on line at https://Dynashop.co.uk/ for all things Dynabrade

Buy parts on line at https://Dynashop.co.uk/ for all things Dynabrade

Summary of Contents for 10671

Page 1: ...applicable safety codes and regulations Please refer to Dynabrade s Warning Safety Operating Instructions for more complete safety information Inlet Outlet Port Size Max Air Pressure Max Air Flow Max...

Page 2: ...valve allows oil to be added to the Lubricator oil reservoir bowl without shutting off the air supply and interruption to work operations 2 Remove the fill black cap plug by turning it counterclockwi...

Page 3: ...es Condition Inlet pressure 102 PSIG Pressure Characteristics Representative values Condition Inlet pressure 102 PSIG Outlet pressure 29 PSIG Flow rate 7 SCFM Standard Specifications Port Size 1 2 Flu...

Page 4: ...Understanding JIS B 8370 General Rules for Pneumatic Equipment and other safety rules are included 3 Do not service the machinery equipment or attempt to remove components until safety is confirmed 1...

Page 5: ...ressure release i e residual pressure may or may not be released depending on the operating conditions b Contact Dynabrade if air will not be consumed in the system for a long period of time or if the...

Page 6: ...ection that increases pressure and lock the knob after the pressure is set If this is done in the direction that decreases pressure the pressure may drop from the original set pressure Turning the kno...

Page 7: ...to the element b Release accumulated condensate periodically before it reaches the maximum capacity Condensate that flows out to the outlet side can cause malfunctions Caution 1 Perform periodical in...

Page 8: ...M Pressure Drop Across FRL PSIG Bar 15 425 2 0 14 30 850 3 0 21 45 1274 6 0 41 60 1699 7 0 48 75 2124 8 0 55 Regulator Lubricator Unit has modular connections with mounting brackets for easy installat...