IMPORTANT SAFETY INFORMATION 

 

 

Installation and repair should be done by a qualified service person. The appliance should be 

inspected before use and at least annually by a professional service person. More frequent 

cleaning may be required due to excessive lint from carpeting, bedding material, etc. It 

is imperative that control compartments, burners and circulating air passageways of the 

appliance be kept clean.

 

 

WARNING:

 Any change to this heater or its controls can be dangerous. 

 

WARNING:

 

Carefully supervise young children when they are in the room with the heater.

 

WARNING: 

Heater becomes very hot when operating. Children and adults should be alerted 

       to the hazard of high surface temperatures and should stay away to avoid burns or clothing 

       ignition Heater will remain hot for a time after shutoff. Allow surfaces to cool before touching. 

 

 

WARNING:

 Make sure any panel, safety screen or guard removed for servicing an appliance   

       is replaced prior to operating the heater
 

WARNING:

 Keep the appliance area clear and free from combustible materials, gasoline, and  

 

other flammable vapors and liquids. 

 

WARNING:

 Do not place clothing or other flammable material on or near the appliance. Never  

 

place any objects on the heater.

       

WARNING:

 Due to high temperatures, locate this appliance out of traffic and away from

       furniture and draperies.
This appliance is intended for supplemental heating.

CARBON MONOXIDE POISONING: 

Early signs of carbon monoxide poisoning resemble the flu with 

headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get 

fresh air immediately! Have heater serviced. Some people are more affected by carbon monoxide than 

others. These include pregnant women, people with heart or lung disease, people who are 

anemic, those under the influence of alcohol, and those living in high altitudes.

NATURAL AND PROPANE/LP GAS:

 Natural and Propane/LP gases are odorless. An odor-making 

agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas 

can fade. Gas may be present even though no odor exists. Make certain you read and understand all 

warnings. Keep this manual for reference. It is your guide to operating this heater safely. 

If the heater is being installed in a residential garage, it must be secured firmly to the 

wall, a minimum of 18 in. (457mm) above the floor. The heater must be located so that it 

is protected against any possibility of damage by a moving vehicle, etc.

Raising the heater will reduce BUT NOT eliminate the possibility of lighting the vapor of any

flammable liquids which may be improperly stored or accidentally spilled. If the smell of 

gasoline is present, do not operate this heater until the area has been properly ventilated.

WARNING:

IMPORTANT:

 Read this owner’s manual carefully and completely before trying to assemble, operate, 

or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, 

explosion, electrical shock, and carbon monoxide poisoning.

Summary of Contents for IR12NTDG-1/NMDG-1

Page 1: ...s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the...

Page 2: ......

Page 3: ...ne Propane Ignition Electronic Push Button Electronic Push Button Manifold Pressure 10 in W C 10 in W C Inlet Gas Pressure Maximum 14 in W C 14 in W C Minimum For purposes of input adjustment 11 in W...

Page 4: ...x 20 94 in x 10 08 in 24 09 in x 28 07 in x 10 51 in Fan Ratings Select Models 120V 60Hz 18W 0 15A 120V 60Hz 18W 0 15A SERIES IR6NTDG 1 NMDG 1 IR12NTDG 1 NMDG 1 MAX BTU 6 000 12 000 Fuel Type Natural...

Page 5: ...DE POISONING Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs the heater may not be working properly Get fresh air immediately Have...

Page 6: ...ot run heater Where flammable liquids or vapors are used or stored Under dusty conditions 7 Before using furniture polish wax carpet cleaner or similar products turn heater and pilot off If heated the...

Page 7: ...heater State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room...

Page 8: ...proximately one 1 ounce 30 mL of water for every 1 000 BTUs 3 Kw of gas input per hour An unvented room heater is intended as a supplemental heater rather than a primary heat source In most supplement...

Page 9: ...unconfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are...

Page 10: ...TU hr Example Gas heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct...

Page 11: ...fresh air by using ventilation grills or duct You must provide two permanent openings one within 12 in of the ceiling and one within 12 in of the floor Connect these items directly to the outdoors or...

Page 12: ...e support legs Select models WARNING Maintain the minimum clearances shown in See Fig 3 If you can provide greater clearances from floor ceiling and joining wall Fig 3 Mounting clearances as viewed fr...

Page 13: ...g 8 1 Wall mounted heater must be disconnected from gas supply and removed from wall before installing fan accessory Contact a qualified service person to do this 2 Remove fan knock out panel using a...

Page 14: ...the heater will be placed for leg installation to prevent scratch ing of the table and or the heater 2 Set back of heater on table with the bottom of heater extending outside the table edge 3 Fasten...

Page 15: ...ting bracket to wall where heater will be located Make sure mounting bracket is level 2 Mark screw locations on wall See Fig 16 Note Mark only last hole on each end of mounting bracket Insert 2 wood s...

Page 16: ...screws ST4 8 15 16 through wall mounting bracket and into expansion brackets 7 Tighten expansion bracket screws ST4 8 15 16 until mounting bracket is firmly fastened to wall 8 Check that the bracket i...

Page 17: ...If gas line pressure is higher heater regulator damage could occur CAUTION Never connect heater directly to an LP supply This heater requires an external regulator not supplied Install the external re...

Page 18: ...3 5kPa The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 5 kPa Pres...

Page 19: ...qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS MANUAL GAS CONTROL 1 STOP Read...

Page 20: ...fter pilot lights Release control knob Note If pilot goes out repeat steps 3 through 7 Wait 1 minute before attempting to light pilot again If after several tries the pilot still goes out turn the gas...

Page 21: ...See Fig 25 MANUAL CONTROL OPERATION Manual valves remain burning in the desired setting until manually turned to OFF See Fig 25 Fig 25 Control Knob Position Manual Thermostatic OPERATION 1 2 3 4 5 O...

Page 22: ...urs your heater could produce increased levels of carbon monoxide If burner flame pattern shows yellow tipping follow instructions under BURNER FLAME PATTERN page 21 Notice Do not mistake orange flame...

Page 23: ...d using compressed air no greater than 30 PSI You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions...

Page 24: ...positioned wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad piezo ignitor or ignition module 7...

Page 25: ...tomer service 4 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Mainte nance p...

Page 26: ...r 3 Clean ODS pilot see Care and Maintenance page 22 Gas odor exists even when control knob is in OFF posi tion 1 Gas leak See Warning Statement at top of page 22 2 Control valve is defective 1 Locate...

Page 27: ...1 Fan housing or blades are dirty 2 Fan rotation is blocked 3 Defective fan 1 See Cleaning Fan page 22 2 Verify wiring is not in fan path 3 Replace fan 1 Verify fan is plugged in and set to MAN or AU...

Page 28: ...038 AQ000038 AQ000038 AQ000038 AQ000006 Ignitor Module 1 AQ000221 AQ000221 AQ000221 AQ000221 LP Regulator Assembly 1 GR 130A 6K GR 130A 12K GR 130A 18K GR 130A 30K Front Grille 1 AQ000099 AQ000099 AQ0...

Page 29: ...______________________________________ TYPE OF STORE __________________________ CITY STATE WHERE PURCHASED ______________________________________________ PRICE PAID _______________________ Please Take...

Page 30: ...ds SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 828...

Page 31: ...lado Utiliza aire ox geno de la habitaci n en la cual est instalado Deben tomarse medidas para una combusti n y aire de ventilaci n adecuados Consulte la secci n Aire para la combusti n y ventilaci n...

Page 32: ......

Page 33: ...umna de agua Presi n de gas de entrada M ximo 14 pulg de columna de agua 14 pulg de columna de agua M nimo Para fines de ajuste de entrada 11 pulg de columna de agua 11 pulg de columna de agua Dimensi...

Page 34: ...pulg x 28 07 pulg x 10 51 pulg Capacidades nominales del ventilador Modelos seleccionados 120V 60Hz 18W 0 15A 120V 60Hz 18W 0 15A SERIE IR6NTDG 1 NMDG 1 IR12NTDG 1 NMDG 1 BTU M X 6 000 12 000 Tipo de...

Page 35: ...ELIGRO DE ENVENENAMIENTO CON MON XIDO DE CARBONO Las se ales tempranas de envenenamiento con mon xido de carbono se parecen a la gripe con dolores de cabeza mareos o n usea Si tiene estas se ales el c...

Page 36: ...ga funcionar el calefactor Donde se almacenen o usen l quidos o vapores inflamables Bajo condiciones de mucho polvo 7 Antes de usar pulidor de mueble cera limpiador de alfombra o productos similares a...

Page 37: ...por un fontanero o t cnico de gas calificado en la Commonwealth de Massachusetts Los vendedores de calefactores complementarios de habitaci n no ventilados accionados por propano o gas natural deben p...

Page 38: ...aproximadamente 1 onza 30 mL de agua por cada 1 000 BTUs 0 3 Kw de entrada de gas por hora Un calefactor no ventilado de habitaci n est previsto como un calefactor comple mentario en lugar de una fuen...

Page 39: ...on puertas son consideradas una parte del espacio no confinado Este calefactor no deber ser instalado en un espacio confinado o construcci n inusualmente herm tica a menos que se tomen medidas para un...

Page 40: ...Ejemplo Le os de calentador a gas __________BTU hr Calentador de agua a gas 30 000 BTU hr Otros aparatos a gas ____BTU hr Calefactor de tiro natural 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr...

Page 41: ...ar dos aberturas permanentes una dentro de 12 pulg del techo y otra dentro de 12 pulg del piso Conecte estos art culos directamente al exterior o a espacios abiertos al exterior Estos espacios incluye...

Page 42: ...Este calentador crea corrientes de aire caliente Estas corrientes mueven al calor a las superficies de la pared contiguas al calefactor La instalaci n del calefactor cerca de revestimientos de vinilo...

Page 43: ...el suministro de gas y retirado de la pared antes de instalar el accesorio del ventilador Contacte a una persona de servicio calificada para hacer esto 2 Retire el panel preperforado del ventilador de...

Page 44: ...llos de las patas de soporte M4 15 1 Ponga abajo una manta sobre la mesa donde se colocar el calentador para prevenir que la instalaci n de la pierna evite rallar la mesa o el calentador 2 Coloque la...

Page 45: ...e montaje Inserte 2 tornillos para madera ST4 8 45 16 en total de a trav s de estos agujeros solamente 3 Retire la cinta y el soporte de montaje de la pared Instalaci n del soporte de montaje en la pa...

Page 46: ...l soporte de expansi n 6 Inserte los expansi n tornillos del soporte ST4 8 15 16 a trav s del soporte y en los soportes de expansi n 7 Apriete los expansi n tornillos del soporte ST4 8 15 16 hasta que...

Page 47: ...a l nea de gas es mayor podr an ocurrir da os al regulador del calefactor PRECAUCI N Nunca conecte el calefactor directamente a un suministro de PL Este calefactor requiere un regulador externo no sum...

Page 48: ...ueba mayores de 1 2 PSIG 3 5kPa El aparato y su v lvula de gas principal deben estar desconectados del sistema de tuber a de suministro de gas durante cualquier prueba de presi n de ese sistema a pres...

Page 49: ...ne el aparato y reemplace cualquier pieza del sistema de control y cualquier control del gas que haya estado bajo el agua INSTRUCCIONES DE ENCENDIDO CONTROL MANUAL DEL GAS 1 ALTO Lea la informaci n de...

Page 50: ...perilla de control Nota Si el piloto se apaga repita los pasos 3 al 7 Espere 1 minuto antes de intentar encender el piloto de nuevo Si despu s de varios intentos el piloto todav a se apaga gire la pe...

Page 51: ...uste Si eso ocurre el calefactor se apa gar El quemador se activar cuando la temperatura ambiente caiga abajo de la temperatura de ajuste La perilla de control se puede ajustar a cualquier nivel de co...

Page 52: ...odr a producir niveles en aumento de mon xido de carbono Si el patr n de la llama del quemador muestra coloraci n amarilla siga las instrucciones bajo PATR N DE LA LLAMA DEL QUEMADOR p gina 21 Aviso N...

Page 53: ...usar una aspiradora en la posici n de soplado Si usa aire comprimido en una lata siga las instrucciones en la lata Si no sigue las instrucciones en la lata podr a da ar el ensamblaje del piloto PRECAU...

Page 54: ...l encendedor no est conectado al cable del encendedor 4 El cable del encendedor est aplastado o h medo 5 Cable del encendedor da ado 6 Encendedor o m dulo de ignici n malo 7 Bater a mala 1 Reemplace e...

Page 55: ...ada del los quema dor es 1 La presi n del distribuidor es de masiado baja 2 El orificio del quemador est obstruido 1 Llame a su proveedor de gas 2 Limpie el quemador ver Cuidado y Manteni miento p gin...

Page 56: ...iloto ver Cuidado y man tenimiento p gina 22 Hay olor a gas inclu so cuando la perilla de control est en la posici n OFF 1 Fuga de gas Ver Declaraci n de advertencia en la parte su perior de la p gina...

Page 57: ...La carcasa o las aspas del ventilador est n sucias 2 La rotaci n del ventilador est bloqueada 3 Ventilador defectuoso 1 Ver Limpieza del ventilador p gina 22 2 Compruebe que el cableado no est en el...

Page 58: ...M dulo del Encendedor 1 AQ000221 AQ000221 AQ000221 10 Soporte del Encendedor 1 AQ000019 AQ000019 AQ000019 11 Pata de Apoyo Modelos seleccionados 2 AQ000038 AQ000038 AQ000038 12 Ensamble del ventilador...

Page 59: ...______________ PRECIO PAGADO __________________ Por favor t mese un minuto para darnos sus respuestas a las siguientes preguntas Todas las respuestas ser n usadas nicamente para investigaci n de merca...

Page 60: ...us registros Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 6440 W Howard St Niles IL 60714 3302 Tel 877 447 4768 www ghpgroupinc com 8280 Austin Av...

Reviews: