Dyna-Glo IR10DTDG-2 Installation & Operating Instructions Manual Download Page 1

1

VENT-FREE INFRARED 

GAS WALL HEATER

MODEL #  IR10DTDG-2

IR12DTDG-2
IR18DTDG-2
IR30DTDG-2

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

This appliance may be installed in an aftermarket, permanently located, manufactured 

(mobile) home, where not prohibited by local codes. 

This appliance is only for use with propane or natural gas. 

This appliance is equipped with a simple means to switch between propane and natural 

gas. Field conversion by any other means including the use of a kit is not permitted.

C           US

C           US

ANS Z21.11.2-2019

Gas Fired Room Heaters

Volume II - Unvented Room Heaters

Questions, problems, missing parts?

 Before returning to your retailer, call our customer 

service department at 1-877-447-4768,

 

8:00 a.m. –  4:30

 

p.m., CST, Monday – Friday or 

email us at [email protected].

WARNING:

 

This appliance is equipped for

Natural and Propane gas. Field conversion is 

not permitted.

WARNING

Do not attempt to access or change

the setting of the fuel selection means.

Access to and adjustment of the fuel selection 

means must only be performed by a qualified 

service person when connecting this appliance to a 

specified fuel supply at the time of installation.

Change of the selector setting to other than the 

fuel type specified at the time of installation could 

damage this appliance and render it inoperable.

The installer shall replace the access cover before 

completing the installation and operating this 

appliance.

WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED 

EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY 

DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

- Do not store or use gasoline or other flammable vapors and Iiquids in vicinity of this or 

any other appliance.
WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s

instructions.

• If you cannot reach your gas supplier, call the fire department.

- Installation and service must be performed by a qualified installer, service agency or 

the gas supplier.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is 

installed. Provisions for adequate combustion and ventilation air must be provided.

Refer to Air For Combustion and Ventilation section on page 8 of this manual.

IMDFIRG2 - 2020-04-2

2

Patent Pending Dual 

Fuel System

Summary of Contents for IR10DTDG-2

Page 1: ...person when connecting this appliance to a specified fuel supply at the time of installation Change of the selector setting to other than the fuel type specified at the time of installation could dama...

Page 2: ......

Page 3: ...ronic Push Button Manifold Pressure 5 in W C 10 in W C 5 in W C 10 in W C Inlet Gas Pressure Maximum 14 in W C 14 in W C 14 in W C 14 in W C M nimum For purposes of input adjustment 6 in W C 11 in W C...

Page 4: ...able vapors and liquids WARNING Do not place clothing or other flammable material on or near the appliance Never place any objects on the heater WARNING Due to high temperatures locate this appliance...

Page 5: ...servicing Only a qualified service person should service and repair heater 9 To prevent performance problems do not use propane LP fuel tank of less than 100 lbs capacity 10 WARNING Do not allow fans...

Page 6: ...DELS The fan kit helps to distribute the warmed air into the space more rapidly NOTE This is an optional accessory and is not required for operation of the heater State of Massachusetts The installati...

Page 7: ...produces approximately one 1 ounce 30 mL of water for every 1 000 BTUs 0 3 Kw of gas input per hour An unvented room heater is intended as a supplemental heater rather than a primary heat source In m...

Page 8: ...unconfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are...

Page 9: ...TU hr Example Gas heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct...

Page 10: ...fresh air by using ventilation grills or duct You must provide two permanent openings one within 12 in of the ceiling and one within 12 in of the floor Connect these items directly to the outdoors or...

Page 11: ...e support legs Select models WARNING Maintain the minimum clearances shown in See Fig 3 If you can provide greater clearances from floor ceiling and joining wall Fig 3 Mounting clearances as viewed fr...

Page 12: ...etween the locked positions 3 Remove plug from the inlet of the NG regulator 4 If the LP plug was removed previously apply thread sealant to ensure that there are no leaks and install the NG plug into...

Page 13: ...FAN OPTIONAL WARNING Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a prope...

Page 14: ...e table where the heater will be placed for leg installation to prevent scratch ing of the table and or the heater 2 Set back of heater on table with the bottom of heater extending outside the table e...

Page 15: ...ounting bracket to wall where heater will be located Make sure mounting bracket is level 2 Mark screw locations on wall See Fig 16 Note Mark only last hole on each end of mounting bracket Insert 2 woo...

Page 16: ...h expansion bracket 6 Insert expansion bracket screws ST4 8 15 16 through wall mounting bracket and into expansion brackets 7 Tighten expansion bracket screws ST4 8 15 16 until mounting bracket is fir...

Page 17: ...ust be a minimum 6 WC for NG 11 WC for LP with a max pressure of 14 WC for NG 14 WC for LP If gas line pressure is higher regulator damage could occur CAUTION Never connect heater directly to an LP su...

Page 18: ...3 5kPa The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 5 kPa Pres...

Page 19: ...echnician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS MANUAL GAS CONTROL 1 STOP Read the safety informat...

Page 20: ...sed for 30 seconds after pilot lights Release control knob Note If pilot goes out repeat steps 3 through 7 Wait 1 minute before attempting to light pilot again If after several tries the pilot still g...

Page 21: ...between HIGH 5 and LOW 1 See Fig 25 MANUAL CONTROL OPERATION Manual valves remain burning in the HIGH setting until manually turned to OFF See Fig 25 Fig 25 Control Knob Position Manual Thermostatic O...

Page 22: ...28 shows a correct burner flame pattern Fig 29 shows an incorrect burner flame pattern with lifting and excessive flame height If burner flame is incorrect turn heater off see To Turn Off Gas to Appli...

Page 23: ...d using compressed air no greater than 30 PSI You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions...

Page 24: ...nnected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Badignitormoduleorignitionmodule 7 Bad battery 1 Replace ODS 2 Replace ODS 3 Replace ignitor cable 4 Free ignitor c...

Page 25: ...Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Mainte nance page 21 or contact customer service Burner...

Page 26: ...r 3 Clean ODS pilot see Care and Maintenance page 22 Gas odor exists even when control knob is in OFF position 1 Gas leak See Warning Statement at top of page 22 2 Control valve is defective 1 Locate...

Page 27: ...E CAUSE PROBLEM QUALIFIED INSTALLING AGENCY Only a qualified agency should perform installation and replacement of gas piping gas utilization equipment or accessories and repair and servicing of equip...

Page 28: ...L 1000 6 Thermostatic Gas Valve SIT 630 1 0630560 0630560 0630560 0630560 7 Manual Gas Valve 1 N A GS7B GHP GS7C GHP GS7C GHP 8 Gas Selector Valve 1 GH01 GH01 GH01 GH01 9 Regulator Bracket 1 AQ000015...

Page 29: ...______________________________________ TYPE OF STORE __________________________ CITY STATE WHERE PURCHASED ______________________________________________ PRICE PAID _______________________ Please Take...

Page 30: ...2 0 7 Tel 847 324 5900 Fax 847 324 5901 Toll Free 877 GHP Group 8 7 7 4 4 7 4 7 6 8 www ghpgroupinc com GHP GHP Group Inc 6440 W Howard St Niles IL 60714 3302 Tel 877 447 4768 www ghpgroupinc com GHP...

Page 31: ......

Page 32: ...este manual Este aparato debe instalarse en una casa m vil prefabricada localizada permanentemente de un mercado de piezas de repuesto donde no est prohibida por los c digos locales Este aparato es s...

Page 33: ......

Page 34: ...g de columna de agua 14 pulg de columna de agua M nimo Para fines de ajuste de entrada 6 pulg de columna de agua 11 pulg de columna de agua 6 pulg de columna de agua 11 pulg de columna de agua Dimensi...

Page 35: ...ustibles gasolina yotros vapores y l quidos inflamables ADVERTENCIA No coloque ropa ni otro material inflamable en o cerca del aparato Nuncacoloque ning n objeto en el calefactor ADVERTENCIA Debido a...

Page 36: ...o vapores inflamables Bajo condiciones de mucho polvo 6 Antes de usar pulidor de mueble cera limpiador de alfombra o productos similares apague el calefactor y el piloto Si se calientan los vapores de...

Page 37: ...ODELOS SELECCIONADOS El juego del ventilador ayuda a distribuir el aire caliente dentro del espacio m s r pidamente Estado de Massachusetts La instalaci n debe ser hecha por un fontanero o t cnico de...

Page 38: ...aproximadamente 1 onza 30 mL de agua por cada 1 000 BTUs 0 3 Kw de entrada de gas por hora Un calefactor no ventilado de habitaci n est previsto como un calefactor comple mentario en lugar de una fuen...

Page 39: ...on puertas son consideradas una parte del espacio no confinado Este calefactor no deber ser instalado en un espacio confinado o construcci n inusualmente herm tica a menos que se tomen medidas para un...

Page 40: ...Ejemplo Le os de calentador a gas __________BTU hr Calentador de agua a gas 30 000 BTU hr Otros aparatos a gas ____BTU hr Calefactor de tiro natural 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr...

Page 41: ...abiertos al exterior Estos espacios incluyen ticos y c maras Siga el C digo Nacional de Gas Combustible NFPA 54 ANS Z223 1 Aire para la combusti n y ventilaci n para el tama o requerido de las rejilla...

Page 42: ...Este calentador crea corrientes de aire caliente Estas corrientes mueven al calor a las superficies de la pared contiguas al calefactor La instalaci n del calefactor cerca de revestimientos de vinilo...

Page 43: ...iciones bloqueadas 3 Retire el tap n de la entrada del regulador de GN 4 Si se retira el tap n de PL usar sellador de rosca para garantizar que no hayan fugas vuelva a colocar el tap n en la entrada d...

Page 44: ...ca a tierra Este aparato est equipado con un enchufe con conexi n a tierra de tres terminales para su protecci n contra peligro de choque el ctrico y debe ser conectado directamente en un recept culo...

Page 45: ...as patas de soporte M4 15 1 Ponga abajo una manta sobre la mesa donde se colocar el calentador para prevenir que la instalaci n de la pierna evite rallar la mesa o el calentador 2 Coloque la parte de...

Page 46: ...ntaje Inserte 2 tornillos para madera ST4 8 45 16 en total de a trav s de estos agujeros solamente 3 Retire la cinta y el soporte de montaje de la pared Instalaci n del soporte de montaje en la pared...

Page 47: ...l soporte de expansi n 6 Inserte los expansi n tornillos del soporte ST4 8 15 16 a trav s del soporte y en los soportes de expansi n 7 Apriete los expansi n tornillos del soporte ST4 8 15 16 hasta que...

Page 48: ...agua WC para GN y de 11 WC para PL con una presi n m xima de 14 CW para GN y de 14 CW para PL Si la presi n de la l nea de gas es m s alta da os al regulador podr a ocurrir PRECAUCI N Nunca conecte el...

Page 49: ...de prueba mayores de 1 2 PSIG 3 5kPa El aparato y su v lvula de gas principal deben estar desconectados del sistema de tuber a de suministro de gas durante cualquier prueba de presi n de ese sistema...

Page 50: ...eemplace cualquier pieza del sistema de control y cualquier control del gas que haya estado bajo el agua INSTRUCCIONES DE ENCENDIDO CONTROL MANUAL DEL GAS 1 ALTO Lea la informaci n de seguridad arriba...

Page 51: ...0 segundos despu s de que el piloto encienda Suelte la perilla de control Nota Si el piloto se apaga repita los pasos 3 al 7 Espere 1 minuto antes de intentar encender el piloto de nuevo Si despu s de...

Page 52: ...e la temperatura de ajuste Si eso ocurre el calefactor se apa gar El quemador se activar cuando la temperatura ambiente caiga abajo de la temperatura de ajuste La perilla de control se puede ajustar a...

Page 53: ...patr n correcto de la llama del quemador La Fig 29 muestra un patr n incorrecto de la llama del quemador con altura de llama excesiva que se levanta Si la llama del quemador es incorrecta apague el c...

Page 54: ...no m s de 30 PSI Puede usar una aspiradora en la posici n de soplado Si usa aire comprimido en una lata siga las instrucciones en la lata Si no sigue las instrucciones en la lata podr a da ar el ensa...

Page 55: ...del encendedor da ado 6 M dulo del Encendedor o m dulo de ignici n malo 7 Bater a mala 1 Reemplace el ODS 2 Reemplace el ODS 3 Reemplace el cable del encendedor 4 Libere el cable del encendedor si est...

Page 56: ...ma dor es 1 La presi n del distribuidor es de masiado baja 2 El orificio del quemador est obstruido 1 Llame a su proveedor de gas 2 Limpie el quemador ver Cuidado y Manteni miento p gina 21 o llame a...

Page 57: ...iloto ver Cuidado y man tenimiento p gina 22 Hay olor a gas inclu so cuando la perilla de control est en la posici n OFF 1 Fuga de gas Ver Declaraci n de advertencia en la parte su perior de la p gina...

Page 58: ...ACCI N CORRECTIVA CAUSA POSIBLE PROBLEMA AGENCIA DE INSTALACI N CALIFICADA Solo una agencia calificada debe efectuar la instalaci n y el reemplazo de las tuber as de gas del equipo o los accesorios e...

Page 59: ...6 Valvula de Gas Termostatica SIT 630 1 0630560 0630560 0630560 0630560 7 Valvula Manual de Gas 1 N A GS7B GHP GS7C GHP GS7C GHP 8 Valvula Selectora de Gas 1 GH01 GH01 GH01 GH01 9 Soporte del Regulado...

Page 60: ...o est n descritas dentro de este documento no aplican a accesorios que no son del fabricante usadas junto con la instalaci n de este producto Esta garant a no tiene validez si a El producto ha sido op...

Page 61: ...gistro de la garant a en el plazo de catorce 14 d as despu s de la fecha de compra Tambi n puede registrar su garant a en internet en www ghpgroupinc com Complete el n mero de serie Conserve esta porc...