PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

Burner backfiring 

during combustion.

1. Burner orifice is clogged or

 damaged.

2. Burner is damaged.

3. Gas regulator is damaged.

1. Clean burner orifice (see Care and 

  Maintenance, page 8 or contact 

  customer service.

2. Contact dealer or customer service.

3. Replace gas regulator.

High yellow flame 

during burner

combustion

1. Not enough air.

2. Gas regulator is defective.

3. Outside temperature is too 

low.

1. Check burner for dirt and debris. If found, 

clean burner (see Care and Maintenance, 

page 8).

2. Replace gas regulator.

3. Buy new tank or refill 20lb tank.

Gas odor during

combustion.

1. Foreign matter between

control valve and burner.

2. Gas leak. (See Warning

Statement on page 2).

1. Take apart gas tubing and remove foreign  

matter.

2. Locate and correct all leaks.

Heater produces a 

clicking/ticking noise 

just after burner is lit 

or shut off.

1. Metal is expanding while

  heating or contracting

  while cooling.

1. This is common with most heaters. If 

noise is excessive, contact qualified 

  service technician.

Heater shuts off in 

use (ODS operates).

1. Not enough fresh air is

 available.

2. Low line pressure.

3. ODS/pilot is partially

 clogged.

1. Open window and/or door for

 ventilation.

2. Contact local gas supplier.

3. Clean ODS/pilot (see Care and 

  Maintenance, page 8).

Gas odor exists 

even when control 

knob is in OFF posi-

tion.

1. Gas leak. See Warning

Statement on page 2.

2. Control valve is

defective.

1. Locate and correct all leaks (see

“Checking Gas Connections” page 4).

2. Contact customer service.

Moisture/conden-

sation noticed on 

windows.

1. Not enough combustion/

  ventilation air.

1. Refer to “Air for Combustion and 

  Ventilation” requirements, page 4.

Slight smoke or odor 

during initial opera-

tion

1. Residues from

  manufacturing process.

1. Problem will stop after a few hours of 

operation.

NEVER LEAVE THE HEATER 

UNATTENDED WHILE BURNING!

10

TROUBLESHOOTING

Summary of Contents for HA1360R

Page 1: ...ervicemustbeperformedbyaqualifiedserviceagency This is an unvented gas fired portable heater It uses air oxygen from the area in which it is used Adequate combustion and ventilation air must be provid...

Page 2: ...e or tank is connected to unit connection must be checked for leaks in one or more ways Apply soapy water to connection look for bubbles listen for hiss of escaping gas feel for extreme cold smell for...

Page 3: ...heater setting it down tip over switch may shut off heater If this happens re light Operating time will vary depending on the heater setting and the supply cylinder size See chart and Cold Weather Ope...

Page 4: ...o replace any part of the control system and any gas control which has been under water When used without adequate combustion and ventilation air this heater may give off excessive CARBON MONOXIDE an...

Page 5: ...en Attach GHP hose end adapter No EH12DG to fuel filter by gently turning clockwise until it is hand tight Do not overtighten Do not use tools to tighten Check for gas leaks by using a 50 soap water s...

Page 6: ...n the OFF position 2 Open the access door and install the propane fuel source a Install a DOT certified 1 lb propane cylinder b Install the GHP hose connector model EH12DG Check for gas leaks by using...

Page 7: ...Group Inc will repair or replacethis product free of charge if it has been proven to be defective within the 1 year period and is returned at customer expense with proof of purchase to GHP Group Inc w...

Page 8: ...can lead to a fire 1 Allow heater to thoroughly cool before performing any maintenance 2 Remove disposable 1 lb cylinder s from heater or turn OFF gas supply at remote cylinder valve and disconnect ho...

Page 9: ...s turned there is a spark at ODS pilot but no ignition 1 Tank shutoff valve is closed 2 Control knob not fully pressed in while pressing ignitor button 3 Air in gas lines when installed 4 ODS pilot is...

Page 10: ...just after burner is lit or shut off 1 Metal is expanding while heating or contracting while cooling 1 This is common with most heaters If noise is excessive contact qualified service technician Heat...

Page 11: ...15 RD HA10360 15 B Access Door 7 1 HA10360 01 HA10360 01 HA10360 10 BurnerAssembly 8 N A HA360 HK HA360 HK HA360 HK Hardware Kit Includes all hardware to assemble unit 9 1 1 HA10360 21 HA10360 21 HA10...

Page 12: ...6 1 HA18360 PBA RD HA18360 PBA B Plastic BaseAssembly 7 2 HA18360 15 RD HA18360 15 B Door 8 1 TT15C 07 TT15C 07 Tip Switch 9 1 2 HA18360 21 HA18360 21 Door Hinge Upper 9 2 2 HA18360 22 HA18360 22 Door...

Page 13: ...ntative This warranty gives you specific legal rights and you may also have other rights which vary from state to state TO REGISTER THE WARRANTY ON YOUR HEATER PLEASE FILL OUT THIS CARD COMPLETELY AND...

Page 14: ...SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 8280...

Reviews: