ITEM
PAGE #
PRECAUTIONS - SAFETY GUIDE ................................................. 3
1. DESCRIPTION .......................................................................... 3
2. SPECIFICATIONS ..................................................................... 3
3. GENERAL SAFETY INFORMATION ........................................ 3
4. LOCATING HEATER ................................................................. 4
5. PRE-INSTALLATION ................................................................. 5
6. INSTALLATION ......................................................................... 6
7. OPERATING INSTRUCTIONS ................................................. 11
8. MAINTENANCE ........................................................................ 13
DESCRIPTION
This Electric Garage Heater is the ideal heating solution for your garage, warehouse, or
workshop with its 2 heat settings, convenient space-saving ceiling-mount, and adjustable
thermostat. To ensure safety this heater was designed with overheat protection and a
caution indicator light.
SPECIFICATIONS
GENERAL SAFETY INFORMATION
CONTENTS OF USER’S MANUAL
This heater requires hardwire installation (no plug). The installation of this
product must be carried out by a certified electrician and in accordance
with all local and national electrical codes.
NOTE: Compatible with a 240V Line Voltage Double Pole Wall Thermostat.
Must be installed by a Certified Electrician.
Read and understand all installation & operation instructions prior to
operating this unit. Observe all safety instructions.
WARNING
WARNING
1. Use only copper wires rated for at least 60ºC.
2. Heater air flow must be directed parallel to or away from adjacent wall.
3. Observe all wall, floor and ceiling clearance requirements.
4. All wiring must be done according to national and local electrical codes. The
heater must be grounded as a precaution against possible electrical shock.
Heater circuit must be protected with proper fuses.
5. The mounting structure and the anchoring hardware must be capable of
supporting the weight of the heater and the mounting bracket (if used).
Rating
AMPS
BTU/hour
7500W II 240-1-60
31.25
22589
5000W I 240-1-60
20.9
17065