background image

2

3

4

6

5

7

8

10

9

11

14

13

15

DYMO bvba, Industriepark-Noord 30, B-9100 Sint-Niklaas - 

Belgium, A Newell Rubbermaid Company, 

www.sanfordbrands.com, Made in China - ©2007 DYMO

12

QUICK TIPS

Label Settings

 

SETTINGS >

 

Current Label Configuration

CLR Key

  Returns to general mode & clears all text, formats, and font settings

Navigation

  Arrows

  Moves to next / previous label = SHIFT + LEFT / RIGHT ARROWS

Numeral Selections

  TOP / BOTTOM ARROWS (Press and hold for faster speed)

   Enter number

Printing

  Multiple prints = SHIFT + PRINT

  Feed the tape = SHIFT + CUT

Insert/Remove Labels

  Insert labels = SHIFT + SAVE

  Remove labels = SHIFT + RECALL

Save/Recall Labels 

  Save labels = SAVE

  Recall labels = RECALL

Serialisation 

  Simple (A1 A2 A3) = SERIAL

  Simultaneous (A1 B2 C3) = SHIFT + SERIAL > Simultaneous

  Advanced (A1 A2 B1 B2 C1 C2) = SHIFT + SERIAL > Advanced

Technical Support: 020 7341 55 29

QUICK REFERENCE GUIDE

GENERAL PURPOSE LABELS

TERMINAL BLOCK LABELS

PANEL LABELS

WIRE LABELS

   

HORIZONTAL    

   

WRAP

1

  Press H. WRAP                   + 

2

  Set label length: AUTO, press OK

3

  Enter text: Bedroom 1 - CATV 

4

  Press PRINT 

   

BACK OF PATCH

   

PANEL 

(#1)

1

  Create a Patch Panel. 

 

(see Patch Panel steps 1 – 6 on page 7) 

2

  Press SHIFT + PPANEL                   +  

3

  Set # of copies to 1 

4

  Press PRINT

   

SELF-

   

LAMINATING

1

  Press SELF-LAM                    + 

2

  Set label length: AUTO, press OK

3

  Type text: A101  

4

  Press PRINT

   

  MODULE

1

  Press MODULE 

2

  Set fuse length: 17,5 mm, 

 

# of modules: 3, 

 

multipliers: module 1, multiplier 1,  

 

 

module 2, multiplier 1, 

  

 

module 3, multiplier 2, 

 

select DONE, press OK

3

  Enter text: Bar

4

   Press                +       one time to move to the next module

5

  Repeat steps 3 – 4 until all modules are labelled

6

  Press  PRINT 

   

FIXED 

   

LENGTH

1

  Press FIXED 

Set the label length: 90 mm, press OK

Enter text: 230 Volts 

Press PRINT

   

VERTICAL

1

  Press VERTICAL 

2

  Select label length: AUTO, press OK

3

  Enter text: RACK3 

4

  Press PRINT 

   

VERTICAL   

   

WRAP

1

  Press V. WRAP 

2

  Select type of wire - COAX, press OK

3

  Enter text: A101 

4

  Press PRINT 

   

FLAG

1

  Press FLAG 

2

  Set flag length: AUTO, press OK

3

  Press LIBRARY

4

  Select VOICE/DATA, press OK

5

  Press L, select LAN, press OK

6

  Press PRINT

 

    

BACK OF PATCH  

    

PANEL 

(#2)

1

  Press PPANEL   

2

  Set port distance: 30 mm, # of ports: 3, select DONE, press OK

3

  Enter text: A01, press ENTER, A02

4

  Press ADV. SER.                   +  

5

  Select SIMULTANEOUS, press OK  

6

  Select 1 to be the first character to be 

 

serialised, press OK  

7

  Select 2 to be the second character to 

 

be serialised, press OK   

8

  Set increment: 2 and # of serialisations: 3, press OK  

9

  Press SHIFT + PPANEL                   + 

10 

Set # of copies to 1, press PRINT  

   

A/V 

   

DISTRIBUTION  

   

PANEL

1

  Press PPANEL 

2

  Select port distance: 40 mm and # of ports: 3, 

 

Set DONE, press OK

3

  Enter text: MSTR BDRM 

4

  Press               +      one time to move to the next connector 

5

  Repeat steps 3 – 4 until first three ports are labelled

6

  Press INSERT                   +               , select insert 

 

next label to the right, press OK

7

  Repeat steps 3 – 6 until all ports are labelled 

8

  Press PRINT                 select all

   

TERMINAL  

    

BLOCK

1

  Press TBLOCK

2

  Set # of blocks: 8, and block size: 6 mm, 

  

select DONE, press OK

3

  Enter text: T01

4

  Press SERIAL 

5

  Select 1 to be serialised, press OK

6

  Set the increment: 1 and # of serialisations: 8, 

  

press OK 

7

  Press PRINT 

   

110 TERMINAL 

   

BLOCK

1

  Press PPANEL 

2

  Set port distance: 30 mm and # of ports: 6, 

 

select DONE, press OK 

3

 

Enter text: 10-110, press ENTER, 20-110

4

  Press ADV. SER.                   + 

5

  Select SIMULTANEOUS, press OK

6

  Select the first character to 

 

be serialised, press OK

7

  Select the second character to

 

be serialised, press OK

8

  Set increment: 1 and  

 

# of serialisations: 6, press OK

9

  Press PRINT 

   

PATCH 

   

PANEL

1

  Press PPANEL 

2

  Set port distance: 17,5 mm and # of ports: 6 (# of ports 

 

grouped together), select DONE, press OK

3

  Enter text: A01 

4

  Press SERIAL 

5

  Select 1 to be serialized, press OK

6

  Set increment: 1 and # of serializations: 6 (total # of     

 

ports), press OK, select DONE, press OK

7

  Press PRINT                select all

   

ELECTRICAL  

   

PANEL

1

  Press TBLOCK 

2

  Set number of blocks: 6, and block size: 25 mm, 

 

select  DONE, press OK

3

  Enter text: Bedroom 1, Press ENTER,  Hallway

4

  Press                   +       to move to next breaker label

5

  Enter text: Kitchen 

6

  Repeat steps 4 – 5 until all breakers are labelled 

7

  Press PRINT 

GENERAL PURPOSE LABELS

TERMINAL BLOCK LABELS

PANEL LABELS

WIRE LABELS

RHINO

TM

 6000

 

P R O F E S S I O N A L   L A B E L L I N G   T O O L S  

931666

Reviews: