22
Dymax Edge-Carry Conveyor User Guide
Conveyor Operation
Operating Instructions for Conveyors Using Dymax 5000-, 2000-, Or
1200-EC Lamp Systems
1.
Install all safety accessories to protect operator from UV light emissions.
2.
Apply power to the conveyor and turn it on.
3.
Using the Speed Control Knob (Figure 48), unlock the Knob and adjust the Chain speed for the desired
setting. The Speed Control Knob is a 10-turn Potentiometer and allows speed adjustment from
approximately 0.8 FPM to 32 FPM (feet per minute).
Figure 48. Speed Control Knob
Figure 49. Front Control Panel with Belt Speed
Indicator Display
4.
If any adjustments are needed for Chain positioning or Chain tension, refer to the Maintenance Section.
5.
Adjust the height of the Lamps to the desired distance (Figure 50).
Figure 50. Conveyor Adjusted to Various Lamp Heights
Note: If needed, the Angle Support (Figure 51) can be removed to gain extra travel. To remove it:
▪
Remove the flood lamps from the conveyor (Figure 52).
▪
Disconnect the Angle Support by removing the three screws and sliding it out from the under the
conveyor’s edge
▪
Remount the flood lamps in the conveyor (Figure 54).