13
Dymax EC-Series Flood Lamps for UVCS Conveyors User Guide
CAUTION!
Always use a soft, clean rag, clean paper towel, or gloves when handling the Bulb.
Skin oils left on the Bulb will burn into the quartz, reducing output intensity. If the Bulb is inadvertently
touched, clean the Bulb thoroughly with a soft, clean rag and alcohol.
Figure 13. Bulb in Reflector
6.
Lightly push the Bulb toward the Lamp Socket on the opposite end of the Bulb so that the end being
grasped can be lifted clear of the Socket as shown in Figure 14 and 15.
Figure 14. Bulb Removal
Figure 15. Bulb Removal
7.
Install the new Bulb by following steps 5, 6, and 7 in the reverse order.
IMPORTANT!
Install the Bulb such that the seal dimple on the bulge of the glass is facing
towards the Reflector surface. Avoid touching the quartz tube with your fingers.
NOTE:
Bulb has no polarity.
8.
Record the serial number of the unit and the Hour Meter reading in the Bulb history record.
9.
Replace the Lamp/Reflector Assembly Housing on the Conveyor Cradle.
10.
Secure the thumbscrew when the Lamp/Reflector Assembly Housing is at the proper height.
11.
Reconnect the Power Cord to the appropriate power source.
12.
Turn the Conveyor on by turning the Power Switch to the on position.
13.
Allow at least 5 minutes for the Bulb to reach operating temperature before using.