![dymax EC Series User Manual Download Page 19](http://html.mh-extra.com/html/dymax/ec-series/ec-series_user-manual_2546031019.webp)
19
Dymax EC-Series Flood Lamps for UVCS Conveyors User Guide
Table 3. Electrical Specifications
Property
Specification
Power Supply
Power Outage Range
Factory set to 395 Watts
Operating Temperature
0 to 40°C
Storage Temperature
-20 to 80°C
Operating Humidity
0-90 % (non-condensing)
Flood Lamps
Main Voltage
90 - 264 VAC
Line Frequency
47-63 Hz
Current Consumption (max)
At 115 VAC 8A
At 230 VAC 4A
Inrush Current (max)
30A
Rated Output Power
450 Watt maximum
Output Protection
Short circuit and overload protected
Auxiliary DC Outputs
+24V, 1A available for lamp housing fan and shutters
+/- 24V, ~0.5A and +6V unregulated
Bulbs
38560
36970
36658
400 Watt, metal halide (standard)
400 Watt, mercury vapor (optional)
400 Watt, visible (optional)
Figure 17. ECE Flood Lamp Spectral Output
Spectral Outputs for DYMAX 400Watt Flood Bulbs
200
250
300
350
400
450
500
550
600
650
700
Wavelength
Re
lative I
ntensity
38560 (Metal Halide)
36970 (Mercury)
36658 (Visible)