9
U S E R G U I D E
|
M O D E L 8 2 8 D I S P E N S I N G V A L V E
Tubing Installation
Figure 3.
Tubing Installation Procedure
Note:
The Model 828 is not supplied with tubing. Various tubing sizes and materials
(including polyethylene, polyurethane, PVC, and silicone) are available for order
through Dymax. This valve is compatible with a maximum tubing size of 0.375" [9.53
mm] OD.
1.
Separate the Tube Support (Figure 3
A) from the Valve Body (Figure 3, B) by
removing the four Socket Head Cap Screws
D).
2.
Place the Tubing (Figure 3, C) in the slot (Figure 3, E) on the Tube Support.
3.
Reconnect the Tube Support to the Valve Body by reinstalling the four Socket
Head Cap Screws.
D - Socket Head Cap
Screws
B - Tube
Support
A - Valve Body
C - Tubing
E - Slot