DYI SHENG DS06-A Operating Manual Download Page 7

6

SCREWS TORQUE GUIDE

Annotation: Please lock it according to the torque value to avoid leakage or over-tightening.

N.m

CN.m

gf.cm

kgf.cm

kgf.m

lbf.in

lbf.

1 N.m

100     

10.19

0.1019

8.852

0.7375

1 gf.cm

9.80E-05 0.00981

0.001 0.00001 0.00868

7.20E-05

1 kgf.cm

0.0981

9.81

1000

0.01

0.868

0.072

1 kgf.m

9.8066

981

100000

100

86.8

7.233

1 lbf.in

0.113

11.3

1150

1.152

0.0115

0.083

1 lbf.

1.355

136

13800

13.83

0.138

12

Unit

Imperial Unit

Tension to Torque Conversion

SI

Gravity Unit

Posi

on

Name

Torque Values(kgf.cm)

#49

1/2" Hexagon Bung

200~210(Max)

#45

M6 Hexagon Screw

25~35(Max)

#12

M8 Steel Hexagon Screw

170~180(Max)

#3

M6 Hexagon Screw

115~125(Max)

#1

M8 Hexagon Screw

150~165(Max)

#32

M6 Hexagon Screw

40~55(Max)

#47

M10 Hexagon Screw

490~545(Max)

Summary of Contents for DS06-A

Page 1: ...DS06 A OPERATING MANUAL ...

Page 2: ...e and Liquids Serviceability Specification 3 Material and Temperature Range 4 Exploded View Drawing 5 Screws Torque Guide 6 Dimensions 7 Important Safety Information 8 Installation Considerations 9 Installation Instructions 10 FAQ 11 Warranty Instructions 12 ...

Page 3: ...e add Bolivian filament ent Current specificalion Size Wetted Body Center Body Pupe Type Diaphragm Ball cover Ball Ball seat Edition 06 3 4 A Aluminum ADC12 A380 A Aluminum T Conter U UPE A Aluminum S S S 316 S Stainless Steel 02 D Doule out in T PTFE TFM P PP T PTFE T PTFE O Santoprene O Santoprene O Santoprene P PP ...

Page 4: ...nyl Chloride Ammonia Asphalt Sulfuric Acid Chromic Acid Electroplate Solu on High Temperature Sauce Chili Sauce Coal Oil Vola le Oil Carrier Oil Immiscible Fluids Freezing Mixture Degreasing Agent Methylene Chloride Jam Juice Ace c Acid Leavan Slops Balsam Olive Oil Defoamer DSXX SAX OXSO X Glaze Po ery Clay Thick Liquid Bolivian Filament Note Depending on the density temperature concentration and...

Page 5: ... thermoplas c vulcanizates TPVs are high performance elastomers which offer manufacturing flexibility ease of processing and durability It combines the characteris cs of vulcanized rubber with the processing proper es of thermoplas cs 40 135゚C Polyethylene PE The thermoplas c resin is made by polymeriza on of ethylene which is also includes a polymer of ethylene and a small amount of the polyethylen...

Page 6: ...8 19 28 ShaftCover A 1 27 19 28 20 28 ShaftCover B 1 27 20 28 21 29 AxisSwitch 1 27 21 29 22 ShaftOfDiaphragm 1 PA000317 23 Oring 2 PB000001 24 Oring 2 PD000001 30 Oring 1 PD000024 31 Oring 1 PD000038 32 HexagonScrew 4 PC000101SW 33 AbnormalOring 1 PD000128 34 AbnormalOring 1 PD000127 35 BodyOfSequential 1 PA000321 36 PistonOfAirValve 1 PA000322 37 Oring 1 PDD00025 38 Oring 2 PDR00018 39 StartingC...

Page 7: ... 1000 0 01 0 868 0 072 1 kgf m 9 8066 981 100000 100 86 8 7 233 1 lbf in 0 113 11 3 1150 1 152 0 0115 0 083 1 lbf 1 355 136 13800 13 83 0 138 12 Unit Imperial Unit Tension to Torque Conversion SI Gravity Unit Posi on Name Torque Values kgf cm 49 1 2 Hexagon Bung 200 210 Max 45 M6 Hexagon Screw 25 35 Max 12 M8 Steel Hexagon Screw 170 180 Max 3 M6 Hexagon Screw 115 125 Max 1 M8 Hexagon Screw 150 165...

Page 8: ...7 DIMENSIONS 148 202 247 306 Fluid Outlet 3 4 Fluid Inlet 3 4 109 50 137 50 176 20 228 Air Inlet 1 4 ...

Page 9: ...8 IMPORTANT SAFETY INFORMATION ...

Page 10: ...es If too much wastewater is introduced into the pump body the wastewater and lubricating oil will emulsify and affect the lubrication of the parts or block the pores thereby affecting the operation performance of the pump or causing malfunction Air Line Moisture Water in the compressed air supply can create problems such as icing or freezing of the exhaust air causing the pump to cycle erraticall...

Page 11: ...le connection Pipe Connection Style Optional Pipe Connection Style Optional Flexible connection Gauge Gauge Shut Off Valve Shut Off Valve Drain Port Drain Port Discharge Suction Air inlet Air shut Off Valve Modular Type F R L Unit INSTALLATION INSTRUCTIONS ...

Page 12: ...mp whether lubricates sufficient or not Please clean up the dirty parts and relubrication It is recommended to add lubricating oil to the air pressure inlet pipeline every half year don t exceed 10ml each time c Sequential valve abnormal If the deterioration of the sequential if it is worn please change it d Compressed Air Lines Freezing The Slithery Mass Valve 53 might be frozen because of low te...

Page 13: ...of the original quality of the product we will change a new one for you Improper use e g Falling Attacked Liquid input etc or abnormal operating conditions e g Flood Fire Earthquake Lightning strike Typhoon etc these damages are not covered by the warranty Improper installation self modifying wear and tear caused by not transporting in accordance with machine regulations Accident or defect caused ...