- 2 -
M965495 Rev. 1.9 (5/17)
1
2
2a
HOSE ASSEMBLY
HAND SHOWER ASSEMBLY
• Insert WASHERS
(1)
into COUPLING NUTS
(2)
of SUPPLY HOSES
(3)
and tighten.
NOTE: Back flow prevention and 2.0 GPM flow restrictions are included with all
Roman tub sets with hand shower.
• T-PIECE
(8)
and COUPLING NUT
(9)
are factory pre-installed on SPOUT
SHANK
(1)
and must be removed to install spout. Unthread COUPLING
NUT
(9)
and pull off T-PIECE
(8)
.
• Insert SPOUT SHANK
(1)
through center hole of sink or mounting
surface. Install WASHER
(2)
.
• Assemble RUBBER WASHER
(3)
, FIBER WASHER
(4)
and
LOCKNUT
(5)
onto threads of SPOUT SHANK
(1)
. Tighten firmly.
• Grease O-RING
(6 & 7)
. Assemble T-PIECE
(8)
onto the SPOUT
SHANK
(1)
and tighten with COUPLING NUT
(9)
.
• Slide the T-PIECE
(8)
onto SPOUT SHANK
(1)
until it
makes contact with the O-RING
(6)
. Thread COUPLING
NUT
(9)
onto SPOUT SHANK
(1)
. Rotate T-PIECE
(8)
about
10 degrees from center and tighten securely. Make sure both
O-Rings
(6 & 7)
are seated into grooves of T-PIECE
(9)
.
SPOUT ASSEMBLY
CAUTION
Turn off hot and cold water
supplies before beginning.
IMPORTANT NOTICE TO THE INSTALLER
Please check with your local Code Authority for acceptable installation requirements forthis
Roman Tub set with hand shower. Some local codes may require a vacuum breaker and/or
a pressure balanced mixing valve to be installed in conjunction with this product.
GROOVE
IN TEE
GROOVE IN TEE
10°
1
2
3
4
5
8
6
9
7
8
14
2
2
1
1
11
12
13
3
3
10
8
BRAIDED
HOSE
16
15
19
9
7
4
3
15
18
17
5
TRANSFER
KNOB
OUTLET
NIPPLE
• Drop SPRAY HOLDER
(4)
into the fourth hole of the tub
ledge or deck (12" max from SPOUT center) directed
towards tub center. Be sure SEAL
(5)
is properly
seated in ESCUTCHEON
(4)
. Install RUBBER
WASHER
(7)
, FIBER WASHER
(8)
and LOCKNUT
(9)
from underside of mounting ledge. Secure
SPRAY HOLDER
(4)
by tightening LOCKNUT
(9)
.
• Install SEAL WASHER
(10)
and connect
COUPLING NUT
(11)
of BRAIDED HOSE
(12)
to outlet nipple. Tighten firmly.
• Slip SHOWER HOSE
(13)
with COUPLING
NUT
(14)
through SPRAY HOLDER
(4)
.
• Check that BACKFLOW PREVENTER
(19)
is installed in HOSE NIPPLE
(16)
.
• Install SEAL
(15)
into COUPLING NUT
(14)
. Connect
COUPLING NUT
(15)
to HOSE NIPPLE
(16)
and tighten.
• INSTALL second SEAL
(15)
and connect HAND
SHOWER
(17)
to SPRAY HOSE END
(18)
. Hand tighten.