- 2 -
M965498 Rev. 1.3 (5/17)
1
2
TRIM INSTALLATION
TEMPERATURE CALIBRATION
• Unscrew PLASTER GUARD SCREWS and remove PLASTER GUARD.
• Check that arrow marking
“B”
points vertically upwards. If not, push the BLACK CLAMP on the SECURING RING to
the right, pull off KNOB MOUNT and reinstall KNOB MOUNT with| arrow
“B”
pointing upwards.
• The maximum mixed water temperature is set at 109˚ F (43° C) at the factory. This setting can be changed if desired.
• Remove the TEMPERATURE LIMIT STOP (H shaped Black Plastic part). Re-install it at the desired notch as indicated in the
diagram to limit the maximum mixed water temperature to 104˚F or 112˚F.
• For 100˚F adjustment, turn the water supply on. Turn KNOB MOUNT until the spout temperature is 100˚F. Check that arrow
marking
“A”
on the KNOB MOUNT still points upward after adjusting the thermostat to 100˚F. If not, pull out the RED
LOCKING DEVICE. Remove KNOB MOUNT by pulling it towards you while standing directlyin front of the valve.
• Reinstall the KNOB MOUNT so that the arrow marking
“A”
points upwards.
• Reinstall RED LOCKING DEVICE.
KNOB
MOUNT
ARROW
"A"
BLACK
CLAMP
ARROW
"B"
RED LOCKING
DEVICE
SECURING
RING
TEMPERATURE
LIMIT STOP
104 °F
(40 °C)
109 °F
(43 °C)
112 °F
(44.4 °C)
• Push CAP
(1)
over the O-RING SEAL
(2)
.
• Push ESCUTCHEON HOLDER and SEAL
(3)
with lightly greased O-ring seal over CAP
(1)
and secure with SCREWS
(4)
.
• Align PINS
(6)
on back side of ESCUTCHEON
(5)
with the HOLES
(7)
in ESCUTCHEON HOLDER
(3)
and press
ESCUTCHEON
(5)
flush against finished wall.
2
1
7
7
3
4
GREASE
ESCUTCHEON
HOLDER
O-RING SEAL
4
6
5