background image

- 2 -

M965498 Rev. 1.3 (5/17)

1

2

TRIM INSTALLATION

TEMPERATURE CALIBRATION

• Unscrew PLASTER GUARD SCREWS and remove PLASTER GUARD. 
•  Check that arrow marking 

“B”

 points vertically upwards. If not, push the BLACK CLAMP on the SECURING RING to 

the right, pull off KNOB MOUNT and reinstall KNOB MOUNT with| arrow 

“B”

 pointing upwards.

•  The maximum mixed water temperature is set at 109˚ F (43° C) at the factory. This setting can be changed if desired.
•  Remove the TEMPERATURE LIMIT STOP (H shaped Black Plastic part). Re-install it at the desired notch as indicated in the 

diagram to limit the maximum mixed water temperature to 104˚F or 112˚F. 

•  For 100˚F adjustment, turn the water supply on. Turn KNOB MOUNT until the spout temperature is 100˚F. Check that arrow 

marking

 

 

“A”

 on the KNOB MOUNT still points upward after adjusting the thermostat to 100˚F.  If not, pull out the RED  

LOCKING DEVICE. Remove KNOB MOUNT by pulling it towards you while standing directlyin front of the valve.

• Reinstall the KNOB MOUNT so that the arrow marking 

“A”

 points upwards.

• Reinstall RED LOCKING DEVICE.

KNOB 

MOUNT

ARROW

"A"

BLACK

CLAMP

ARROW

"B"

RED LOCKING

DEVICE

SECURING

RING

TEMPERATURE

LIMIT STOP

104 °F

(40 °C)

109 °F

(43 °C)

112 °F

(44.4 °C)

• Push CAP

 (1)

 over the O-RING SEAL 

(2)

.

• Push ESCUTCHEON HOLDER and SEAL 

(3)

 with lightly greased O-ring seal over CAP 

(1)

 and secure with SCREWS

 (4)

•   Align PINS 

(6) 

on back side of ESCUTCHEON

 (5)

 with the HOLES

 (7)

 in ESCUTCHEON HOLDER 

(3) 

and press 

ESCUTCHEON

 (5)

 flush against finished wall.  

2

1

7

7

3

4

GREASE

ESCUTCHEON

HOLDER

O-RING SEAL

4

6

5

Summary of Contents for Rem D35100510

Page 1: ... plumbing supply stores It is essential that the tools and materials be on hand before work is begun ROUGHING IN DIMENSIONS For reference 1 0 0 In the United States DXV One Centennial Avenue Piscataway New Jersey 08855 Attention Director of Customer Care For residents of the United States warranty information may also be obtained by calling the following toll free number 800 227 2734 www DXV com I...

Page 2: ...r supply on Turn KNOB MOUNT until the spout temperature is 100 F Check that arrow marking A on the KNOB MOUNT still points upward after adjusting the thermostat to 100 F If not pull out the RED LOCKING DEVICE Remove KNOB MOUNT by pulling it towards you while standing directlyin front of the valve Reinstall the KNOB MOUNT so that the arrow marking A points upwards Reinstall RED LOCKING DEVICE KNOB ...

Page 3: ...RE KNOB 2 This will increase the mixed water temperature up to the maximum limit previously selected in step 1 Push TEMPERATURE CONTROL KNOB 1 onto KNOB MOUNT 2 Attach TEMPERATURE CONTROL KNOB 1 to valve with ATTACHMENT SCREW 3 Push HANDLE 4 onto TEMPERATURE CONTROL KNOB 1 Tighten SET SCREW 5 with HEX WRENCH 6 to secure HANDLE 4 6 5 1 0 0 2 1 3 4 1 0 0 1 2 ...

Page 4: ...ropriate finish code POLISHED CHROME 100 BRUSHED NICKEL 144 D35100510 MODEL NUMBER 1 0 0 H960680 XXX THERMO CARTRIDGE COVER H961281 XXX TRIM PLATE A860821 XXX HANDLE ADAPTER A860822 XXX HANDLE A961057 191 SET SCREW H961241 191 TRIM PLATE HOLDER H960892 191 HANDLE EXTENSION KIT A860826 191 ESCUTCHEON SCREWS ...

Reviews: