background image

- 3 -

M965560  Rev. 1.3 (5/17) 

2

3

POP-UP DRAIN

REMOVE FLANGE

INSTALL DRAIN FROM

BELOW FIXTURE

FLANGE GASKET AND POP-UP KNOB

TIGHTEN LOCKNUT

• Remove CLEAR PLASTIC COVER 

(1)

Fig. A.

•  Remove CARDBOARD SPACER 

(2)

 from 

under DRAIN POP-UP

 (3)

Fig. A.

•   Tighten TAILPIECE

 (4)

 on DRAIN BODY  

before installing DRAIN BODY. 

Fig. B.

•  Thread FLANGE

 (1)

 counter-clockwise and 

remove FLANGE

 (1)

 and FOAM GASKET

 (2)

 

from drain body.  

Fig. A.

•  Thread LOCKNUT

 (3) 

clock-wise to bottom of 

drain body. Push GASKET

 (4)

 down against 

LOCKNUT 

(3)

Fig. B.

•  From under side of SINK 

install DRAIN BODY

 (1) 

up 

through drain outlet.

Note:

  No plumber’s putty 

or caulk is required. The 
CABLE ATTACHMENT 
POINT

 (2)

 must face towards 

the rear of the SINK.

•  Install FOAM GASKET

 (3)

 

and FLANGE

 (4) 

onto drain 

body from above SINK and 
tighten FLANGE 

(4) 

firmly.

•  Check DRAIN FLANGE in SINK to ensure that 

WHITE FOAM GASKET

 (3)

 is fully compressed 

and not visible. 

Fig. A

.

•  POP-UP KNOB 

(1)

 must be fully down. 

Fig. B.

2

3

1

DRAIN

BODY

4

Fig.

 

A.

Fig.

 

B.

2

3

1

4

Fig.

 

B.

Fig.

 

A.

WHITE FOAM

GASKET

NOT VISIBLE

DRAIN

FLANGE

Fig.

 

A.

DOWN

UP

1

Fig.

 

B.

Fig.

 

A.

2

DRAIN

OUTLET 

1

3

4

REAR OF SINK

1

•  Tighten LOCKNUT

 (1)

 firmly with 

Adjustable Wrench or Channel Locks.

Summary of Contents for Randall D35102100

Page 1: ...MOUNTING HOLE 1 3 8 DIA 35 mm 12 5 16 316 mm 4 1 8 105 mm 8 1 8 206 mm 3 1 16 DIA 77 mm 6 152 mm MTG SURFACE 24 610 mm 2 1 16 MAX 53 mm 12 MAX 305 mm MAX 2 51 mm 1 1 4 O D 32 mm 3 8 32 mm SUPPLIES Flat Blade Screwdriver Plumber s Putty or Caulking Adjustable Wrench Tubing Cutter Channel Locks In the United States DXV One Centennial Avenue Piscataway New Jersey 08855 Attention Director of Customer ...

Page 2: ...INING WASHER 4 and LOCKNUT 6 onto faucet SHANK 3 Before final tightening faucet should be seated flush on mounting surface Adjust faucet so that it is centered and covers mounting hole Tighten LOCKNUT 6 using a 15mm or adjustable wrench Do not over tighten Installation is the same for VESSEL FAUCET 8 INSTALL FAUCET LAVATORY AND VESSEL FAUCETS CAUTION Turn off hot and cold water supplies before beg...

Page 3: ... against LOCKNUT 3 Fig B From under side of SINK install DRAIN BODY 1 up through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET 3 is fully compressed and not visible ...

Page 4: ... to the troubleshooting section of these instructions Connect FLEXIBLE SUPPLIES 1 2 directly to wall supplies Connection on fitting supplies are 3 8 10 mm compression Connect left SUPPLY 1 to Hot Marked with a Red Band and right supply to COLD 2 wall supply Faucet supplies are 24 610 mm long from faucet base Note If additional supply length is required installer must purchase additional parts sepa...

Page 5: ...ections for leaks Remove AERATOR 3 Operate HANDLE 1 to flush water lines thoroughly Replace AERATOR 3 CHECK DRAIN CONNECTIONS Operate POP UP KNOB 4 and fill lavatory with water Check that DRAIN STOPPER 5 makes a good seal and retains water in sink If DRAIN STOPPER 5 does not seal properly please refer to Troubleshooting section in these instructions Release POP UP KNOB 4 down and check all drain c...

Page 6: ...ap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F If sink does not hold water even though Stopper is in the down position Follow CABLE ADJUSTMENT PROCEDURE ...

Page 7: ...USTMENT PROCEDURE in Troubling Shooting Guide to complete installation Stopper will be in Locked mode and not be removable UNLOCKED MODE Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink Rotate Sto...

Page 8: ...iate finish code POLISHED CHROME 100 BRUSHED NICKEL 144 PLATINUM NICKEL 150 M952425 XXX DRAIN ASSEMBLY A860811 XXX HANDLE ASSEMBLY M964732 YYY0A LIFT KNOB ROD M952430 0070A SPPED CONNECT ASSEMBLY Vessel Faucet M964733 YYY0A CAP AND NUT M964507 0070A MOUNTING KIT M964737 YYY0A AERATOR ASSEMBLY M964736 YYY0A ROSETTE A860621 191 CARTRIDGE ASSEMBLY Lavatory Faucet ...

Reviews: