- 3 -
M965911 (8/18)
4
5
FLANGE GASKET AND POP-UP KNOB
CHECK OPERATION OF POP-UP
• Check DRAIN FLANGE in SINK to ensure that
FOAM GASKET
(3)
is fully compressed and not visible.
FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
2
3
INSTALL DRAIN FROM BELOW FIXTURE
• Install DRAIN
(1)
by dropping it from the top of the sink.
• From under side of SINK install GASKET
(2)
and
MOUNTING NUT
(3)
.
Note:
Plumber’s putty or caulk is recommended.
• Thread TAIL PIECE NUT
(1)
clockwise onto
DRAIN BODY
(2)
.
DRAIN
OUTLET
REAR OF SINK
1
2
3
1
2
1
• Operate DRAIN STOPPER
(1)
to verify that it opens
and closes.
• With HANDLE
(1)
in OFF position, turn on WATER
SUPPLIES
(2)
and check all connections for leaks.
• Remove AERATOR
(3)
.
• Operate HANDLE
(1)
to flush water lines thoroughly.
• Replace AERATOR
(3)
.
CHECK DRAIN CONNECTIONS
• Fill lavatory with water. Check that DRAIN STOPPER
(4)
makes a good seal and retains water in SINK.
• Release DRAIN STOPPER
(4)
down and check all drain
connections and “P” trap for leaks. Tighten if necessary.
TEST INSTALLED FITTING
6
2
3
2
1
1
4
“P” TRAP
WASTE
OUTLET