background image

- 2 -

6

3

5

4

Figure 2.

Figure 3.

7

3

2

5

2

MIDDLE

NOTCH

VALVE CARTRIDGE

15

131

197

531

1

5

4

3

2

4

15

13

1

1

9

7

5

3

1

 

15

1

3

1

1

9

7

5

3

1

 

COLDER

(Larger Numbers)

0 1 3 5 7 9 11 13 15

HOTTER

(Smaller Numbers)

0 1 3 5 7 9 11 13 15

1

5

3

2

M965571 REV. 1.8 (5/18)

1

2

3a

3b

ADJUST HOT LIMIT STOP (MUST BE DONE PRIOR TO TRIM INSTALLATION)

INSTALL VALVE TRIM

INSTALL VALVE TRIM

By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold,  
the HOT LIMIT SAFETY STOP

 (1)

 reduces risk of accidental scalding. To set the maximum hot water  

temperature of your faucet, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP

 (1)

.

•  Turn CARTRIDGE STEM

 (2)

 to the OFF  

position (coldest setting) before making  
adjustment to HOT LIMIT STOP 

(1)

. Use  

a flat blade screwdriver to pry free the  
HOT LIMIT SAFETY STOP 

(1)

. Pull  

forward and rotate counterclockwise one  
number to limit hot water temperature.  
Use ARROW 

(3)

 on CARTRIDGE

 (4)

 and  

NUMBERS 

(5)

 on HOT LIMIT STOP

 (1)  

for indication.

•  

Figure 2.

 Push CAP

 (2)

 over VALVE CARTRIDGE until 

seated against stop.

•  Mount ESCUTCHEON HOLDER 

(3)

 and gasket to  

valve body with SCREWS

 (4)

. Mount ESCUTCHEON  

SUPPORT (

5)

 to ESCUTCHEON HOLDER 

(3)

  

with SCREWS 

(6)

.

NOTE:  Make sure the Middle Notch is in the 

vertical position.

•  

Figure 3.

 Install ESCUTCHEON 

(7) 

onto CAP

 (2) 

and push flush against  

finished wall. Escutcheon 

(7)

 will snap fit onto ESCUTCHEON SUPPORT 

(5)

.

• 

Figure 1

. When finished tiling the wall, remove PLASTER GUARD

 (1)

.

REMOVE PLASTER GUARD

CAUTION

Turn off hot and cold water 

supplies before beginning.

Figure 1.

1