•  Place the tub on a finished, level floor in the 

desired location.

ª  Using an erasable pencil or marker, trace the outline of  

the base of the tub on the floor. (See

 Fig. 1

)

•  Using the adjustable feet on the underside of the tub,  

ensure that the tub is level. 

•  Ensure that there is a gap between the tub base and the floor.   

Gap shall not exceed 1/8" [3 mm]. (See

 Fig. 2 

)

•  Using the traced outline for reference, confirm that the  

drain/waste outlet in the floor will align with the tub drain outlet.

  
(Tub drain outlet will be located in the center of the traced  
outline. See 

Fig. 3

)

Note:  The drain/waste outlet must be installed in 

accordance with all local building codes. 

All drain connections must be made using an 
access created beneath the tub. 

•  The tail piece assembly, consisting of a flanged tail piece, drain  

tail piece gasket and slip-joint nut used to connect the the tub  
drain to the drain/waste outlet, is included with this product. 

•  The 1-1/2" diameter tail piece is compatible with drain provided.   

(See 

Fig. 4

)

• Slide the slip-joint nut over tail piece towards the flanged end as shown.

• Slide the P-trap slip-joint nut and seal over the tail piece as shown.

• Insert the tail piece into the P-trap

.

•  The flange of the tail piece should be approximately 5-3/4" [145 mm] or 

4-7/8" [124 mm] depending on model, above the finished floor when fully 
inserted into the P-trap.  

• The tail piece can be cut if necessary.

INSTALLATION INSTRUCTIONS: 

REMOVE THE TUB 

INSTALLING THE 1-1/2" DIAMETER TAIL PIECE ASSEMBLY 
INTO P-TRAP

FIG. 1

1/8" MAX

  (3 mm)

FIG. 2

FINISHED FLOOR

FIG. 3

DRAIN

FLOOR CUTOUT

TRACED 

OUTLINE

 DRAIN TAIL PIECE GASKET

SLIP-JOINT NUT

TAIL PIECE

P-TRAP

FIG. 4

(INCLUDED)

 THREADED PORTION

OF DRAIN BODY

TAIL PIECE

ASSEMBLY

For MODEL# 

D12536-004

5-3/4" [145 mm]

For MODEL# 

D12536-014

4-7/8" [124 mm]

   FINISHED

     FLOOR

SLIP-JOINT NUT

P-TRAP

& SEAL

(PROVIDED BY 

   INSTALLER)

(PROVIDED BY 

   INSTALLER)

Summary of Contents for EQUILITY D12536-004

Page 1: ...or selecting DXV To ensure this product is installed properly please read these instructions carefully before you begin Certain installations may require professional help Also be sure your installation conforms to local codes CAUTION PRODUCT IS FRAGILE TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE Product names listed herein are trademarks of AS America Inc AS America Inc 2018 754988 100...

Page 2: ...ONTENTS Cover Page 1 Table of Contents Page 2 Safety Instructions Notice Page 3 General Installation Information Page 4 Tub Specifications Page 5 Roughing in Reference Page 6 Freestanding Tubs Page 7 Post Installation Instructions Page 8 ...

Page 3: ...ian before using this product WARNING Risk of personal injury Do not overfill bathtub before entering Entering tub when filled more than 2 3 can cause overflow and slippery conditions Exercise caution when entering and exiting WARNING No Food or Alcoholic Beverages Use of your bathtub immediately after meals is not recommended Avoid alcohol consumption before or during bathing Alcoholic beverages ...

Page 4: ...e drain with tape 3 Fill tub and allow tub to stand for five minutes Examine all fittings carefully for leaks NOTE The overflow is a plumbing device designed to prevent water from reaching a certain level in your tub DO NOT under any circumstances tape off or block the overflow in any way 4 If any leaks or operating problems are discovered do not complete installation until problems are resolved D...

Page 5: ...070 x 495 mm 60 1 8 x 27 1 4 1527 x 692 mm 672 lbs 305 kg 57 lbs ft 279 kgs m 122 lbs 55 kg 66 gal 250 l For more details see specification page per model at www dxv com The drain outlet is directly under the drain hole in the tub ROUGHING IN REFERENCES FREESTANDING MODELS see appropriate sections for details Equility Model D12536 014 5 1 2 x 33 1676 x 838 mm Equility Model D12536 004 5 1 2 x 30 1...

Page 6: ...asket and slip joint nut used to connect the the tub drain to the drain waste outlet is included with this product The 1 1 2 diameter tail piece is compatible with drain provided See Fig 4 Slide the slip joint nut over tail piece towards the flanged end as shown Slide the P trap slip joint nut and seal over the tail piece as shown Insert the tail piece into the P trap The flange of the tail piece ...

Page 7: ...where it meets the floor Remove any excess caulking FIG 5 No fixtures can be mounted on the tub deck of freestanding tubs Floor or wall mounted fixtures are required Wall Mounted The position of the tub and the reach of the spout are critical Pay special attention to the spout reach when choosing your fixtures Be careful to ensure the spout will extend out far enough to clear the tub flange and th...

Page 8: ...x 1 800 395 1498 www DXV ca In Mexico DXV Via Morelos 330 Col Santa Clara Coatitla Ecatepec Estado de México 55540 Toll Free 01 800 8391200 www DXV mx 754988 100 Rev D 5 18 POST INSTALLATION CLEAN UP Remove all construction debris from bath Tile grout can be removed with a wooden Popsicle stick or tongue depressor Do not use wire brushes or any other metal implement on bath surface Post installati...

Reviews: