DX DXE-RR2X8B Manual Download Page 3

Specifications 

 

Power Rating: 

6 kW ICAS all modes, under 2:1 SWR, 4 kW CCS all modes, under 2:1 SWR 

 

Control Voltage

: +10-14 Vdc at 100 mA per port 

 

Port-to-Port Isolation

: >70 dB below 30 MHz, >60 dB below 60 MHz  

 

Ports Not Selected

: Are Grounded 

 

Loss

: <0.3 dBm below at 52 MHz 

 

Impedance

: 50 ohms 

 

Dimensions

: 10.375" x 9.875" x 4.375" and the mounting flange hangs down 2.25" 

 

Control Line

: Dual 8-wire line larger than #24 for runs up to 500 ft. (or 9-conductor for 

dedicated ground). When using 8-conductor wire the feedline serves as a ground return. Use 
of two 

DXE-CW9

 CAT-5 or standard low voltage control wiring, such as telephone wire, is 

acceptable. 

 

General Information  

 

The

 DXE-RR2X8B

 uses a dual star arrangement of 24 relays to select one or more of eight output 

ports when voltage is applied from two 8-wire control lines.  
 
The 24 relays provide greatly improved power handling, port-to-port isolation and SWR over 
conventional switches and allow connection between any of the eight antenna output ports from 
either the Main or Secondary input ports.  
 
The system offers virtually no loss at HF and excellent low-loss performance (less than 0.16 dB loss 
on six meters). 

 
 

Installation

 

 

1.   Secure the 

RR2X8B

 switching unit using the included DXE

-

SSVC-2P

 stainless steel V-Saddle Clamp. For outdoor 

installations or in moist environments, connectors must face 
downward. Use Jet-Lube SS-30, Never-Seez

®

 or Anti-Seize on 

all stainless steel hardware to prevent galling. 

 
2.   Fasten all cables to the mounting mast or tower to relieve strain, 

and gently droop the cables to form a drip loop (do not use tight 
bends with coaxial cable). Install the 

RR2X8B

 with the 

connectors facing down and use gradual bends or loops in heavy 
wires. If the

 RR2X8B

 is mounted to a wooden pole or building, 

a wide copper flashing or heavy wire or strap should be 
connected from the mounting bracket to a good ground. 

Summary of Contents for DXE-RR2X8B

Page 1: ...Switch DXE RR2X8B DXE RR2X8B INS Revision 0d DX Engineering 2020 1200 Southeast Ave Tallmadge OH 44278 Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E mail DXEngineer...

Page 2: ...an open Another example would be if the Secondary has selected port 5 and you are transmitting and the Main then selects port 5 the Main takes port 5 and Secondary will then be transmitting into an o...

Page 3: ...e greatly improved power handling port to port isolation and SWR over conventional switches and allow connection between any of the eight antenna output ports from either the Main or Secondary input p...

Page 4: ...est working your way up through the pairs by ascending color brown brown white orange orange white green green white blue and blue white M MAIN Connector Wire Reference Table G 1 2 3 4 5 6 7 8 G S SEC...

Page 5: ...the Secondary has selected port 5 and you are transmitting and the Main then selects port 5 the Main takes port 5 and Secondary will then be transmitting into an open A very simplified schematic is s...

Page 6: ...6 Notes...

Page 7: ...e heavy jacket without worry about nicking or accidentally cutting the conductors Excellent for use in all outdoor applications of switching networking data transfer and phone lines As a data transfer...

Page 8: ...llation damaged from severe weather including floods or abnormal environmental conditions such as prolonged exposure to corrosives or power surges or by the performance of repairs or alterations outsi...

Reviews: