Introduction 

The 

DXE-RR8B-SD

 is the largest switch in the DX Engineering RR8 series. It is designed to 

switch coaxial lines in high-power RF systems. RF rated enclosed relays with wide contact gaps 
provide exceptional RF voltage and current capability. The 

RR8B-SD

 can be used to 

simultaneously select multiple output ports as well as conventional one-of-eight antenna switching.  
This allows the 

RR8B-SD

 to be used in complex antenna phasing and stacking systems as well as 

traditional switching arrangements. The 

RR8B-SD

 also uses a removable screw terminal control 

cable plug. The removable plug greatly simplifies installation by eliminating the need for soldering. 
Disassembly is not required for control wiring access 
 
The 

RR8B-SD

 also offers the following features: 

•   RF Shielded Weatherproof Housing - unique protection 
•   Excellent Port Isolation; greater than 60 dB at 30 MHz, worst case. 
•   High-RF tolerant, Amphenol UHF connectors 
•   Shorted or open selection of unused antenna ports 
•   Enclosed 25-ampere high-voltage RF relays 
•   Safe 12-volt relay operation 
•   MOV Lightning protection on control lines 

 

 

Specifications 

Power Rating: 

>10 kW normal amateur operation on all modes when using antennas with less than 

2:1 SWR on 30 MHz and below. >5 kW above 30 MHz. 

Control Voltage

: 10-14 Vdc at 160 mA 

Port-to-Port Isolation

: >60 dB below 30 MHz 

Impedance

: 50 ohms  

Control Line

: Control lines (usually BCD ) can normally use good quality CAT5e cable (4 twisted 

pairs of 24 AWG wire) for runs up to 1000 feet.  Typical DX Engineering BCD control lines 
requirements are +12 VDC at 25 milliamps. Depending on the number of control lines needed 
(usually 3 or 4) you can double up the twisted pairs of CAT5e cable, or use control wire that is at 
least 22 AWG, allowing runs up to 1500 feet. If you use a cable with more conductors, it is a good 
idea to tie the unused conductors to ground. For longer runs of control cable, use a line loss 
calculator to ensure you supply the proper control levels needed. 
 
Approximate BCD Control Line Lengths. 
 

Minimum Copper 

Wire Gage (AWG) 

Length 

24 

1,000 feet 

22 

1,500 feet 

20 

2,000 feet 

 

Theory of Operation  

The 

RR8B-SD

 uses a star arrangement of eight relays to select one or more of eight output ports 

when voltage is applied from an 8-wire control line. The eight RF-rated relays provide greatly 
improved power handling and SWR over conventional switches and allows port-to-port connections 
between any of the eight output ports.  

Summary of Contents for RR8B-SD

Page 1: ...Remote Antenna Switch DXE RR8B SD INS Revision 1a DX Engineering 2013 P O Box 1491 Akron OH 44309 1491 USA Phone 800 777 0703 Technical Support and International 330 572 3200 Fax 330 572 3279 E mail DXEngineering DXEngineering com ...

Page 2: ...er Rating 10 kW normal amateur operation on all modes when using antennas with less than 2 1 SWR on 30 MHz and below 5 kW above 30 MHz Control Voltage 10 14 Vdc at 160 mA Port to Port Isolation 60 dB below 30 MHz Impedance 50 ohms Control Line Control lines usually BCD can normally use good quality CAT5e cable 4 twisted pairs of 24 AWG wire for runs up to 1000 feet Typical DX Engineering BCD contr...

Page 3: ...te them in the Connector Wire Reference Table below Either G is ground We recommend following standard resistor color codes using ascending order by color The color code is black 0 brown 1 red 2 orange 3 yellow 4 green 5 blue 6 violet 7 gray 8 and white 9 The green connector is in two parts and the top part can be removed by pulling it straight off This will allow easier wire replacement or servic...

Page 4: ...arts adjustment or repairs or any other work unless such charges are authorized in advance by DX Engineering If DX Engineering s products are claimed to be defective in material or workmanship DX Engineering shall upon prompt notice thereof issue shipping instructions for return to DX Engineering transportation charges prepaid by Buyer Every such claim for breach of these warranties shall be deeme...

Reviews: