DXE-SNS-CT1 - Compression Tool for Snap-N-Seal 75 ohm Coaxial Connectors

 

Ratchet compression tool for installing 

DXE-SNS6 

Snap-N-Seal coaxial connectors. Ordinary pliers will not 

install these connectors properly.  

 
 
DXE-SNS6-25 - Watertight Coaxial Connector, Snap-N-Seal for CATV F-6 Cable, 25 pieces  

Snap-N-Seal is an environmentally sealed CATV F coaxial connector system for harsh environments. The connectors have a unique, 
360 degree radial compression system that offers the signal leakage protection required for high performance receive systems.  

 

Quad sealed system prevents moisture from migrating into the connection  

 

360 degree radial compression provides superior RF integrity (-95 dB typical, 60% bonded foil cable)  

 

Easy cable preparation  

 

Connector to cable retention of 40 lbs minimum  

 

Superb impedance match to 1 GHz  

 

Manufactured of high quality 360 brass, cadmium plated with yellow chromate coating for maximum 
corrosion resistance  

 

UV-resistant plastic and O-rings provide a reliable environmentally sealed connector 

An installation tool, such as the

 DXE-SNS-CT1

 is required to install the connectors. Normal crimping tools or pliers will not work.  

 

 

DXE-CIT-1  -  F Connector Tightening Tool 

The CIT-1 installs and removes F connectors in high density and hard to reach locations, and is the only tool that works 
with bent coax.  Only finger force is required. Provides enough leverage to achieve a 30 in/lb tightening force by hand. 
Helps insure proper connections thereby reducing the potential of loose connector related service calls.  

 

 
PTX-82180 - Permatex® Black RTV Sealant, Non-Acetic - 3.3 oz Tube, Black RTV Sealant 

By Permatex®.  

We have all used RTV to seal water out of things, right? Have you ever sealed a piece of electronic gear with it -- 
then opened it some time later to find that it had still managed to become corroded inside? Guess what? It's not the 
rain that corroded it - It's the RTV!  Normal RTV gives off acetic acid when it cures. That's the vinegar smell.  The 
acetic acid causes the corrosion. DX Engineering has located a Neutral Cure RTV made right here in Ohio that is 
non-corrosive and is safe for sealing those baluns and other electronic gear that are going to be out in the weather.  
Applies just like "normal" RTV, dries in one hour and cures in 24 hours at 70 degrees F. And it doesn't smell like 
vinegar! 

 

3.3 oz. Tube,  Black

       *This part is classified hazardous and is limited to domestic UPS Ground shipping only

 

 

 

PTX-22058  -  Permatex® Dielectric grease, 3 oz. 

Dielectric grease is ideal for keeping moisture from entering your coaxial connectors.  It also acts as a lubricant allowing easy 
connector removal by stopping corrosion of electrical connectors.  Multi-use 3 oz package. 
Safe for all RF connections.  
 

 
 
DXE-RLP-75FF  -  Lightning Protector, Receive 75Ω, DC Pass, F Conn

 

Unique In-Line® design is impedance matched to 75Ω and is virtually transparent to all analog or digital bi-directional  signals from 
DC to 1.0 GHz. Tii's patented proprietary coaxial gas tube surge protector is equipped with an integral fail short mechanism for a 
power-cross condition which shunts both the coaxial cable’s center conductor and sheath for a common path to 
ground.  The DC breakdown voltage of the protector provides superior protection against transient surges, yet is 
compatible with network powered applications. The protection element is designed to reset after each over 
voltage event. Metallic housing of the Tii In-Line® Coaxial Lightning Surge Protector provides necessary EMI 
shielding. When properly connected the protector is environmentally sealed (15 psi) to prevent ingress of 
moisture and humidity encountered in broadband pedestals, vaults, NIDs and stand alone applications. Full 360˚ 
“F” port connectors provide superior RF performance and tighter connections 
 
 

Summary of Contents for DXE-RPA-1

Page 1: ...PA 1 DXE RPA 1 INS Rev 4b U S Patent No 7 319 435 DX Engineering 2017 1200 Southeast Ave Tallmadge OH 44278 USA Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E mail D...

Page 2: ...ents mounted on a sturdy G 10 fiberglass circuit board The circuit board mounts in an aluminum enclosure best suited for indoor use RF connectors are RCA phono and F type CATV fittings Performance is...

Page 3: ...OI the less likely adjacent strong signals will cause interference The DXE RPA 1 offers substantially improved TOI over competitive preamplifiers and communication receivers The figure to the right il...

Page 4: ...r coax seal Lower gaps or seams must be left open to allow condensation drainage Mount the flanges of the box flat against a horizontal surface or with the two mounting flanges positioned in a vertica...

Page 5: ...ather than at the DXE RPA 1 The DXE RPA 1 power connector uses a standard 2 1 mm barrel type plug included You can use a well regulated 13 8 Vdc supply provided it supplies 12 18 Vdc negative ground h...

Page 6: ...o installations rarely suffer damage from lightning even though they never disconnect their equipment the best protection is to disconnect electrical devices during storms The key to proper lightning...

Page 7: ...nd that it had still managed to become corroded inside Guess what It s not the rain that corroded it It s the RTV Normal RTV gives off acetic acid when it cures That s the vinegar smell The acetic aci...

Page 8: ...laimed to be defective in material or workmanship DX Engineering shall upon prompt notice thereof issue shipping instructions for return to DX Engineering transportation charges prepaid by Buyer Every...

Reviews: