Introduction 

The DX Engineering 

DXE-40VE-1

 is a fast taper 33 feet high 40 meter monoband vertical antenna 

system. The vertical antenna operates over the entire 40 meter band with a SWR less than 1.5:1. 
There are no traps, coils or linear loading elements to rob power. Designed with 6063 corrosion-
resistant aluminum tubing and stainless steel hardware, this antenna is very durable and attractive.  
The antenna may be used as a monoband antenna on a higher frequency by simply telescoping the 
tubing inward to one quarter wavelength on the desired band. As supplied, an extra element section 
is part of the design to allow extension to 36 feet if necessary. 
 

Summary of Contents for DXE-40VE-1

Page 1: ...tenna DXE 40VE 1 DXE 40VE 1 INS Revision 13a DX Engineering 2012 P O Box 1491 Akron OH 44309 1491 USA Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E mail DXEngineeri...

Page 2: ...ms 15 Technical Support and Warranty 19 Introduction The DX Engineering DXE 40VE 1 is a fast taper 33 feet high 40 meter monoband vertical antenna system The vertical antenna operates over the entire...

Page 3: ...will be working Don t assume that wires are telephone or cable lines check with your electric utility for advice Although overhead power lines may appear to be insulated often these coverings are int...

Page 4: ...lit one end 1 1 3 8 1 375 x 36 Element split one end 1 1 1 4 1 250 x 36 Element split one end 1 1 1 8 1 125 x 36 Element split one end 1 1 1 000 x 36 Element split one end 1 7 8 0 875 x 36 Element spl...

Page 5: ...a system With a vertical antenna system the radials are the second half of the antenna The radials contribute to the radiation efficiency of the entire vertical antenna system At a minimum 20 radials...

Page 6: ...tical Base Section The base section is made up of an insulated mounting channel an aluminum mount plate and the base antenna section which is 36 long with a hole drilled at one end Nested inside the b...

Page 7: ...t of thread above the nut The standard 1 1 4 galvanized water pipe with its approximate 1 7 OD is just fine for this application and can usually be found at your local home building supply store This...

Page 8: ...r the DXE 22600 Deburring Tool with Extending Handle and Extra Blades for this operation 2 Clean the inside of the aluminum tubing to clear out any dirt or foreign material that would cause the alumin...

Page 9: ...ll the clamps should be positioned approximately 1 8 from the top of each section and the body of the clamp should be positioned between the slits as shown in Figure 5 Figure 5 Using Figure 6 on the n...

Page 10: ...9 Figure 6 Finished Antenna Assembly The top section may be adjusted to vary the overall length from 33 to 36 feet for fine tuning if necessary...

Page 11: ...with an SWR of under 1 5 1 using the indicated section lengths Local conditions including proximity to structures other antennas the number of radials or personal preference may require a slight re ad...

Page 12: ...l Guying should be tightened just enough to permit the antenna to swing a few inches The ends of the ropes are tied to the earth anchors at ground level When using the optional Tilt Base position the...

Page 13: ...ached These kits come in 20 Ft 32 Ft or 65Ft lengths To connect a coax feedline to the vertical you may use an SO 239 connector on the Radial Plate This will also provide a means to ground the feedlin...

Page 14: ...eplace the larger mounting plate with the smaller mounting plate included with the DXE TB 4P If your vertical is already installed you will have to disassemble it Remove the vertical section from the...

Page 15: ...pre drilled braids a stainless steel bracket and stainless steel hardware Also pictured below is the optional DXE RADP 3 Radial Plate and DXE TB 4P Tilt Base The DXE CAVS 2P V Saddle clamp used to mo...

Page 16: ...this reason it is not recommended for softer aluminum tubing or pipe Ideal for fastening a radial plate and antenna mounting to a steel pipe Used to clamp 1 to 2 OD steel tubing or pipe Designed for...

Page 17: ...ine to eliminate the risk of damaging your radials during lawn maintenance 100 count 6 Pins 11 Gauge DXE STPL 100P Radial Wire Anchor Pins 100 pack DXE STPL 300P Radial Wire Anchor Pins 300 pack DXE 2...

Page 18: ...or part thereof which is proved to be other than as warranted no allowance shall be made for any labor charges of Buyer for replacement of parts adjustment or repairs or any other work unless such cha...