Dwyer Instruments W.E. Anderson Flotect V4 Series Specifications-Installation And Operating Instructions Download Page 3

INSTALLATION

1.  Remove packing material from switch body-cap and remove tape

from magnet keeper. Adjust vane length if necessary on multi-layer
vanes only (see flow rate charts on next page). Install switch in
thredolet previously welded to  line. In some cases, it may be
necessary to install the switch in a flange or tee (see installation
drawings on next page). Note: extreme care must be exercised in
welding the fitting to the line so that it is plumb and level.

ADJUSTMENT OF MULTI-LAYER VANE

Remove only those layers which are too long. Leave the smaller 
layers to reinforce the vane. The longest vane fits 6˝ (150 mm) or 
larger pipe, the second longest vane fits 4˝ (100mm) pipe, etc. 
Actuation-Deactuation rates are shown in the charts on the next 
page. To remove vane layers, proceed as follows: 

a. Remove the two screws and lockwashers holding the layers
together. Do not lose these special corrosion resistant type 316
stainless steel screws and lockwashers.

b. Remove the unwanted layers.

c. Resecure the vane with the original two screws and
lockwashers.

d. With a hammer, lightly peen the ends of the screws so that they
can't back out.

e. If you lose the screws or lockwashers, don't replace with other
parts which may corrode and break. That will void the warrantee
and might cause severe damage to equipment located
downstream of the switch.

Note:

Custom vane units have been calibrated at factory to meet

requirements. Do not change.

2.  The arrow on the side of the switch must point in the direction of

flow.

3.  Wiring: UL and CSA units only: thread connecting wires through

conduit and connect. Wire in accordance with local electrical
codes.
Black - Common
Blue - N.O.
Red - N.C.

Note:

Double pole, double throw switches have dual black, 

blue  and red leads. These are connected in the same manner 
as single pole, double throw switches, as described above.

EC-Type Certificate Installation Instructions:
Cable Connection
The cable entry device shall be an EEx d certified cable gland 
suitable for conditions of use and correctly installed. The certified
cable gland and cable shall be rated for a minimum temperature 
of 80°C. 

Conduit Connection
An EEx d certified seal device such as a conduit seal with setting
compound suitable for conditions of use and correctly installed 
shall be provided immediately to the entrance of the electrical 
housing. The certified conduit seal with setting compound and 
cable shall be rated for a minimum temperature of 80°C. 

Note:

The switch is deactivated and contacts are in normal 

condition when there is no flow in the line.

4.  Make sure conduit or cable are properly sealed. Electrical

components must be kept free of moisture, including
condensation, at all times. 

CAUTION:

To prevent ignition of

hazardous atmosphere, disconnect the device from the supply
circuit before opening. Keep assembly tightly closed when in
operation.

Note:

ATEX units only: The temperature class is determined by the

maximum ambient or medium/process temperature. The
approved ratings are: T6 -20°C

)

Tamb

)

75°C. Product may be

used in a maximum ambient or medium/process temperature of
75°C.

1-5/

8

 [41

.

2

8

]

CLEARANCE FOR 
COVER REMOVAL

3-11/32

8

4

.

93

2-23/32

[69,06]

1-1/2 MALE NPT

PROCE

SS

 CONNECTION

[25

.

40]

A

B

C

D

E

F

G

S

TANDARD V4

8

10

9

6

7

4

3

1

2

3

4

5

7

6

9

10

8

CENELEC V4

NC

C

NO

Ref #

1
2
3

4
5
6

7

8

9

10

Standard V4

N/A
N/A
Explosion-proof housing 
with 3/4˝ female NPT 
conduit connection.
16 AWG, 6˝ (152 mm) long.
Internal
Magnet arm and switch 
assembly. 
Switch body of SAE 72 
Brass or 316 Stainless Steel.
Five layer vane, 316 Stainless
Steel, Designed for 1/2˝ to 8˝
pipes. Usable in larger pipe 
sizes.
Magnet keeper of 430 
Stainless Steel.
Vane block of 316 Stainless 
Steel.

ATEX/SAA

Cover lock.
External ground.
Explosion-proof housing with
3/4˝ female NPT conduit
connection.
Terminal Block
Internal ground.
Magnet arm and switch assembly.

Switch body of SAE 72 Brass or
316 Stainless Steel.
Five layer vane, 316 Stainless
Steel, Designed for 1/2˝ to 8˝
pipes. Usable in larger pipe
sizes.
Magnet keeper of 430 Stainless
Steel.
Vane block of 316 Stainless
Steel.

Dim

A

B

C

D

E

F

G

V4 in (mm)

8-3/16 (207.96)

6 (152.40)

4-11/16 (119.06)

1 (25.40)

1-5/16 (33.34)

7/8 (22.23)

11/16 (17.46)

V4-2 in (mm)

8 (203.20)

6-3/4 (171.45)

3-15/16 (100.01)

1-3/4 (44.45)

9/16 (14.30)

11/16 (17.63)

1/2 (12.70)

ATEX/

S

AA

TERMINAL CONNECTIONS

SPDT

TERMINAL CONNECTIONS

DPDT

Northeast Controls Incorporated

Tel: 845-986-8546 | Fax: 845-810-7625

[email protected]

Northeast Controls Incorporated

Tel: 845-986-8546 | Fax: 845-810-7625

www.dwyerstore.com

Summary of Contents for W.E. Anderson Flotect V4 Series

Page 1: ...tomatically to protect equipment and pipeline systems against damage from reduction or loss of flow The V4 is time tested being installed in thousands of pipelines and processing plants around the world A unique magnetically actuated switching design gives superior performance There are no bellows springs or seals to fail Instead a free swinging vane attracts a magnet within the solid metal switch...

Page 2: ...ion Terminal Block Wire Connections Time Delay Relay On flow decrease Time Delay Relay On flow increase Vertical Up Flow Applications Flange Process Connection 2 2 1 2 3 4 Carbon Steel 316 SS Monel Hastelloy B Hastelloy C 150 300 600 900 Bushing Process Connection 2 2 1 2 4 Hex Flush Brass Carbon Steel 316 SS 304 SS Tee Process Connection 1 1 2 Tee with Bushing Process Connection Both same materia...

Page 3: ...rtified seal device such as a conduit seal with setting compound suitable for conditions of use and correctly installed shall be provided immediately to the entrance of the electrical housing The certified conduit seal with setting compound and cable shall be rated for a minimum temperature of 80 C Note The switch is deactivated and contacts are in normal condition when there is no flow in the lin...

Page 4: ...PE 65 32 30 20 23 13 10 6 3 PIPE 210 105 100 50 120 70 60 30 60 48 30 20 4 PIPE 400 200 190 90 195 140 90 70 135 100 60 50 65 50 30 20 6 PIPE 950 475 450 220 550 375 260 180 375 265 180 130 260 200 120 90 130 100 60 50 8 PIPE 1550 850 730 400 1100 700 520 330 725 500 340 240 500 400 240 190 310 250 150 120 10 PIPE 2400 1300 1100 600 1850 1200 870 570 1200 850 570 400 875 700 410 330 650 525 310 25...

Page 5: ...en von Rohrleitungen und Prozessfirmen eingesetzt Der Wächter basiert auf einem magnetischen Prinzip Es gibt keine Kol ben Federn oder Dichtungen die ausgetauscht werden müssten Das frei schwingende Paddel aktiviert einen Magneten innerhalb des soliden metallischen Körpers der wiederum einen Mikroschal ter auslöst HAUPTMERKMALE Leckagedichter Körper Eine Auswahl an kundenspezifischen Paddeln Modell ...

Page 6: ...ontakte NACE Heat Treated Koerper Neoprene Schutz Kein elektrisches Gehaeuse geschweisste Verbindungen Klemmleiste Zeitverzoegerungsrelais steigend Zeitverzoegerungsrelais fallend Vertikale Montage Flanschanschluss 2 2 1 2 3 4 Stahl 316 Edelstahl Monel Hastelloy B Hastelloy C 150 300 600 900 Muffenanschluss 2 2 1 2 4 Hex Flush Messing Stahl 316 Edelstahl 304 Edelstahl T Stueck Anschluss 1 1 2 T St...

Page 7: ...elverschraubungen eingesetzt wer den die bis mindestens 80 C zugelassen sind Gehäuseverschraubung Bei einem EEx d zertifiziertes Gerät muss unverzüglicher Zugang zu dem Inneren des Ge häuses gewährleistet sein Das Kabelmaterial und die Durchgangsdichtung sollten mindestens bis 80 C geeignet sein Bemerkung Der Wächter ist deaktiviert und die Kontakte sind in normaler Schaltung wenn sich die Flüssigk...

Page 8: ...PE 65 32 30 20 23 13 10 6 3 PIPE 210 105 100 50 120 70 60 30 60 48 30 20 4 PIPE 400 200 190 90 195 140 90 70 135 100 60 50 65 50 30 20 6 PIPE 950 475 450 220 550 375 260 180 375 265 180 130 260 200 120 90 130 100 60 50 8 PIPE 1550 850 730 400 1100 700 520 330 725 500 340 240 500 400 240 190 310 250 150 120 10 PIPE 2400 1300 1100 600 1850 1200 870 570 1200 850 570 400 875 700 410 330 650 525 310 25...

Page 9: ...ériels et systèmes des dommages du à la diminution ou la perte de débit Installé dans des milliers de pipe line et d usine dans le monde entier Ce détecteur a actionnement magnétique donne d excellente performance Il n y a ni soufflet ressort ou joint pouvant provoquer des disfonctionnement la pale attire l aimant monté dans le corps et actionne le contact au moyen d un simple levier CARACTÉRISTIQ...

Page 10: ...r Bornier Relais temporisé débit croissant Relais temporisé débit décroissant Application pour débit vertical vers le haut Bride de raccordement tuyauterie 2 2 1 2 3 4 Acier carbone Inox 316 Monel Hastelloy B Hastelloy C 150 LBS 300 LBS 600 LBS 900 LBS Raccordement avec pièce fileté sur tuyauterie 2 2 1 2 4 Hexagonal Affleurant Laiton Acier carbone Inox 316 Inox 304 Raccordement tuyauterie par Té ...

Page 11: ...ions d utilisation et convenablement installé Le câble et le presse étoupe utilisés doivent tenir une température minimum de 80 C Connexion du presse étoupe Un scellement certifié EEx d approprié aux conditions d utilisations et correctement utilisé directement à l entrée du boîtier électrique Le scellement et le câble doivent tenir une température minimum de 80 C Note le détecteur est désactivé e...

Page 12: ...8mm 2 65 32 30 20 23 13 10 6 Tuyau 76 2mm 3 210 105 100 50 120 70 60 30 60 48 30 20 Tuyau 101 6mm 4 400 200 190 90 195 140 90 70 135 100 60 50 65 50 30 20 Tuyau 152 4mm 6 950 475 450 220 550 375 260 180 375 265 180 130 260 200 120 90 130 100 60 50 Tuyau 203 2 mm 8 1550 850 730 400 1100 700 520 330 725 500 340 240 500 400 240 190 310 250 150 120 Tuyau 254 mm 10 2400 1300 1100 600 1850 1200 870 570 ...

Page 13: ...camente para proteger a los equipos y sistemas de tuberias contra el daño producido por el aumento o descenso del caudal El V4 sobradamente probado se ha instalado en miles de tuberías y plantas de procesos en todo el mundo El diseño único del contacto le confiere una actuación superior No existen muelles resortes o sellos que se puedan romper En su lugar una paleta de libre movimiento atrae a un ...

Page 14: ...Conexión soldada Conexiones eléctricas en un bloque terminal Relé de retardo de actuación en descenso de caudal Relé de retardo de actuación en ascenso de caudal Aplicaciones verticales Conexión a proceso bridada 2 2 1 2 3 4 Acero carbono 316 SS Monel Hastelloy B Hastelloy C 150 300 600 900 Conexion a proceso del casquillo 2 2 1 2 4 Hexagonal Superficial Latón Acero carbono 316 SS 304 SS Conexión ...

Page 15: ...ra minima de 80 C Conexión del conducto Para la entrada del alojamiento eléctrico se debe suministrar un mecanismo de cierre EEx d con componentes adecuados para las condiciones de uso y correctamente instalados Nota El interruptor se desactiva y los contactos estan en condicion normal cuando no haya caudal en la linea 4 Asegurarse que las conductos o cables están correctamente sellados Los compon...

Page 16: ...0 190 310 250 150 120 Tuberia 10 2400 1300 1100 600 1850 1200 870 570 1200 850 570 400 875 700 410 330 650 525 310 250 Tuberia 12 3450 1900 1600 900 2700 1750 1300 800 1850 1300 870 610 1250 1000 590 470 1000 800 470 380 Tuberia 20 10000 5500 4700 2600 7400 4800 3500 2300 5300 3700 2500 1700 3900 3100 1800 1500 3550 2850 1700 1300 Tuberia 18 8000 4400 3800 2100 6000 3900 2800 1800 4300 3000 2000 1...

Reviews: