CuRRENT (4-20 mA) OuTPuT OPERATION

An external power supply delivering 10-30 VDC with minimum current capability of
40 mA DC (per transmitter) is required to power the control loop. See Fig. A for
connection of the power supply, transmitter and receiver. The range of appropriate
receiver  load  resistance  (R

L

)  for  the  DC  power  supply  voltage  available  is

expressed by the formula:

Shielded cable is recommended for control loop wiring.

Conduit  Housing  with    4-20  mA  Output (-CH)

Electrical  connections  to  the

pressure transmitters are made to the terminal block located inside the housing.
Remove the screws and lift off the cover. Wire as shown in Fig. A, B or C. Use Fig.
A for current output connection. Use Fig. B for current output with optional LED
display. Use Fig. C for current output with optional LED display using two power
supplies. 

If  ordering  optional  pre-wired  cable,  black  wire  is  negative  (-)  and  red  wire  is
positive (+).

SPAN

ZERO

PRESS AND HOLD TO

ZERO THE DISPLAY

PRESS TO

DISPLAY 

THE GAGE’S 

PRESSURE

RANGE

YELLOW

LED DISPLAY  CONNECTOR

TERM 1 (+)

TERM 2 (-)

TERM 4 (+)

OPTIONAL LED DISPLAY

RECEIVER

mA

LED DISPLAY

POSITIVE SUPPLY

10-30 VDC

(140 ma)

POWER

SUPPLY

+

-

TRANSMITTER CONNECTION:
- TURN OFF POWER
- CONNECT THE POWER SUPPLY 
  AND RECEIVER TO TERM 1 AND 
  TERM 2 OF THE GAGE AS SHOWN
- CONNECT POWER SUPPLY (+) TO 
  TERMINAL 4 (REQUIRED FOR THE
  OPTIONAL DISPLAY ONLY)
- INSTALL THE DISPLAY’S CONNECTOR
- TURN ON POWER

     BE SURE TO TURN OFF POWER WHEN
     CONNECTING OR REMOVING THE
     DISPLAY’S CONNECTOR. FAILURE TO DO
     SO CAN RESULT IN THE GAGE DAMAGE.

R

L

Max =    Vps – 10  

20 mA DC

1 RED

2 BLACK

3 (NC)

4 (NC)

+ RECIEVER -

mA

PRESSURE

TRANSMITTER

POWER

SUPPLY

10-30 VDC

Fig. A: Current output connection

Current Output

Fig. B: Current output with optional LED display connection

Fig. F: Packard Connection

SPAN

ZERO

PRESS AND  HOLD TO

ZERO THE DISPLAY

PRESS TO

DISPLAY

THE GAGE’S

PRESSURE

RANGE

LED DISPLAY CONNECTOR

YELLOW

OPTIONAL LED DISPLAY

10-30 VDC

(40 ma)

10-30 VDC

(100 ma)

+

-

+

-

RECEIVER

mA

LED DISPLAY

NEGATIVE SUPPLY

LED DISPLAY

POSITIVE SUPPLY

TERM 1 (+)

TERM 2 (-)

TERM 3 (-)

TERM 4 (+)

     BE SURE TO TURN OFF POWER WHEN
     CONNECTING OR REMOVING THE
     DISPLAY’S CONNECTOR. FAILURE TO DO
     SO CAN RESULT IN THE GAGE DAMAGE.

TRANSMITTER CONNECTION:
- TURN OFF POWER
- CONNECT THE POWER SUPPLY
  AND RECEIVER TO TERM 1 AND
  TERM 2 OF THE GAGE AS SHOWN
- CONNECT LED POWER SUPPLY (-) 
  TO TERMINAL 3
- CONNECT LED POWER SUPPLY (+)
  TO TERMINAL 4
- INSTALL THE DISPLAY’S CONNECTOR
- TURN ON POWER

POWER

SUPPLY

LED SUPPLY
POWER SUPPLY

Fig. C: Current output with optional LED display using two power supplies

Fig. D

 

 

 

 

 

A

A

SECTION A-A

TERMINAL 1: (+)

TERMINAL 2: (-)

TERMINAL 3:
(GROUND)

TERMINAL 4: (-)

TERMINAL 1: (+)

T

   

   

 

 

Fig. E

Hirschman  DIN  Connector  with  4-20  mA 

When  using  cable  version  of  -GH

General Purpose Housing, black wire is negative (-) and red wire is positive (+).
When using optional Hirschman DIN Plug, remove top-center screw and lift off the
terminal block assembly. Wire to terminals shown below in Fig. D. For optional 4-
pin M-12 connector, wire to pins as shown in Fig. E.

B; [+]

C; [Vout +]

 A; [-]

B; [+]

C; [GND]

A; [-]