background image

Series 1900 Pressure Switch

Specifications - Installation and Operating Instructions

Bulletin E-56

Advanced design and precision construction permit these switches to perform many 

of the tasks of larger, costlier units. Designed for air conditioning service, they also 

serve many fluidics, refrigeration, oven and dryer applications. For use with air and 

non-combustible gases. 

Series 1900 Pressure Switches

 are available with set points 

of 0.07 to 20 inches water column. Set point adjustment can be made easily - before or 

after installation. Range screw is inside conduit enclosure to help prevent tampering. 

For  easy  mounting  and  access,  pressure  and  electrical  connections  and  set  point 

adjustment are located on one side. This permits installation in corners or spaces too 

small for other switches.

SPECIAL MODELS & ACCESSORIES

Special close coupled street elbow for right angle pressure connections. Can be 

installed on switch anytime. Zinc plated aluminum.

SPECIFICATIONS

Service: 

Air and non-combustible, compatible gases.

Environment: 

Standard model intended for indoor use.

Wetted Materials: 

Consult factory.

Temperature Limits: 

-30 to 180°F (-34 to 82.2°C) (32°F for non dry air).

Pressure Limits: 

45 in w.c. (11.2 kPa) continuous, 10 psig (68.95 kPa) surge.

Humidity Limit:

 80% RH (non-condensing).

Altitude Limit:

 6560 ft (2000 m) max.

Switch Type: 

Single-pole double-throw (SPDT).

Repeatability:

 ±3%.

Electrical Rating:

 15 A @ 120-480 VAC (~), 60 Hz. Resistive 1/8 HP @125 

VAC(~), 1/4 HP @ 250 VAC(~), 60 Hz. Derate to 10 A for operation at high cycle 

rates.

Electrical Connections: 

3 screw type, common, normally open and normally 

closed.

Installation Category: 

III (transient over-voltage).

Process Connections: 

1/8˝ female NPT.

Mounting Orientation: 

Diaphragm in vertical position. Consult factory for other 

position orientations.

Set Point Adjustment: 

Screw type inside conduit enclosure.

Pollution Degree: 

2.

Weight: 

1lb. 4.5 oz. (581 g).

Agency Approvals: 

CE, UL, CSA, FM.

2-11/32 [59.53]

ø 7/8 [22.23]

CONDUIT 

CONNECTION

51/64 

[20.24]

2-9/32 [57.94]

2-7/16 [61.90]

1-7/8 

[47.63]

1-3/4 [44.45]

CLEARANCE 

FOR

COVER REMOVAL

1-19/32

[40.48]

1/8 FEMALE NPT

 HIGH PRESSURE

CONNECTION 

3

[76.20]

ø 3-1/2

[88.90]

1/8 FEMALE 

NPT LOW

PRESSURE 

CONNECTION

(2) ø 3/16 [4.76]

MOUNTING 

HOLES ON 

A 4-3/16

 [106.36] B.C.   

60° TYP

1-5/16

[33.32] 

TYP

41/64

[16.27]

The  Dwyer-engineered  force-motion  amplifier  increases  the  leverage  of 

diaphragm  movement  and  results  in  a  switch  with  excellent  sensitivity  and 

repeatability.    

Series  1910  pressure  switch.  All 

pressure  and  electrical  connections 

and set point adjustments are on one 

side for easy installation.

Series  1910  switch  with  conduit 

enclosure off. Shows electric switch 

and set point adjustment  screw.

Weatherproof Housing

16  ga.  steel  enclosure  with  gasketed  cover  (NEMA  4)  for  wet  or  oily  conditions. 

Withstands 200 hour salt spray test. Wt. 5 Ibs. (2.3 kg). Switch must be factory installed. 

Change 1910 base number to 1911 and add -WP suffix. Example: 1911-1-WP.

Explosion-Proof Housing

NEMA 7, 9 NEMA 3. (7 lbs). Switch must be factory installed. Change model to 1911 

and add -EXPL suffix. Example: 1911-1-EXPL. Aluminum base and cover rated Class 

I, Groups C & D, Div. 1. Class II, Groups E, F, & G, Div. 1.

6-1/2 [165.10]

CLEARANCE FOR 

COVER REMOVAL

1/2 NPT 

PROCESS CONNECTION

3X 1-1/16 

[26.99]

6-5/8 

[168.28]

3 [76.20]

2X 4-1/4

[107.95]

2X 6-1/8

[155.58]

1/8 FEMALE NPT

LOW PRESSURE 

CONNECTION

4X Ø.281 

[7.14]

1/8 FEMALE 

NPT HIGH PRESSURE 

CONNECTION

EXPLANATION OF SYMBOLS

Symbol Publication

Description

   

IEC 60417 - 5032

IEC 60417 - 5019

Alternating current

Protective conductor terminal

SERIES 1910 SWITCHES - MODELS OPERATING RANGES, DEADBANDS

Model

Operating Range, 

in w.c.

Approximate Dead Band

At Min. Set Point At Max. Set Point

1910-00

1910-0

1910-1

1910-5

1910-10

1910-20

0.07 to 0.15

0.15 to 0.5

0.40 to 1.6

1.40 to 5.5

3.0 to 11.75

4.0 to 20.0 

0.04

0.10

0.15

0.30

0.40

0.40

0.04

0.10

0.16

0.30

0.40

0.50

NC

NO

COM

POWER INPUT

TERMINALS

+  –

GROUNDING

SCREW

~

DWYER INSTRUMENTS, INC.

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.

Phone: 219/879-8000
Fax: 219/872-9057

www.dwyer-inst.com
e-mail: [email protected]

®

HIGH PRESSURE

CONNECTION 1/8 N.P.T.

LOW PRESSURE

CONNECTION 1/8 N.P.T.

3/4 [19.05]

3/4 [19.05]

1-1/4

[31.75]

3/32

[2.381]

3 [76.20]

3-1/8

[79.38]

5-7/16 [138.1]

4-3/4 [120.7]

4 [101.6]

7/8 [22.22]

1-1/8 [28.58]

1/2 NPT WEATHERPROOF

ELECTRICAL CONNECTION

Ø5/16

[Ø7.938]

3 [76.20]

2 [50.80]

Summary of Contents for 1900 Series

Page 1: ...EMOVAL 1 19 32 40 48 1 8 FEMALE NPT HIGH PRESSURE CONNECTION 3 76 20 ø 3 1 2 88 90 1 8 FEMALE NPT LOW PRESSURE CONNECTION 2 ø 3 16 4 76 MOUNTING HOLES ON A 4 3 16 106 36 B C 60 TYP 1 5 16 33 32 TYP 41 64 16 27 The Dwyer engineered force motion amplifier increases the leverage of diaphragm movement and results in a switch with excellent sensitivity and repeatability Series 1910 pressure switch All ...

Page 2: ...terest of prolonging switch life OPERATION Pressure acting on the power diaphragm rotates the amplifying lever which in turn extends the range spring and rotates the snap switch input lever When the set point is reached the snap switcch is actuated and the electrical contacts make or break ADJUSTMENT To change the set point proceed as follows A Remove the snap on cover from the conduit enclosure b...

Page 3: ...II sobretensión transitoria Conexiones a proceso 1 8 NPT hembra Orientación de montaje Diafragma en posición vertical Consulte con la fábrica para las orientaciones otra posición Ajuste del punto de ajuste Tipo de tornillo interior de la caja del conducto El grado de contaminación 2 Peso 1 lb 4 5 oz 581 g Aprobaciones de las agencias CE UL CSA y FM Opcional EXPL caja prueba de explosions no posee ...

Page 4: ...CION La presión actúa sobre el diafragma girando la palanea amplificadora Esta a su vez extiende el resorte antagónico de calibrasión el que está mecánicamente vinculado a la palanca actuadora del interruptor inversor Al alcanzarse el valor preajustado la condición de los contactos se invierte es decir el NA pasa cerrado y el NC pasa abierto AJUSTE Para cambiar el ajuste proceda de la siguiente ma...

Reviews: