Dwyer Instruments 1430 Installation And Operating Instructions Download Page 1

Model 1430 Microtector

®

Electronic Point Gage

Installation and Operating Instructions

Model 1430 Microtector

®

Portable 

Electronic Point Gage

combines mod-

ern, solid-state integrated circuit elec-
tronics with a time-proven point gage
manometer to provide fast, accurate
pressure measurements.

SPECIFICATIONS AND FEATURES

*

Accurate and repeatable to ± .00025 
inches water column

Pressure range: 0 - 2˝ w.c., positive, 
negative, or differential pressures

Non-toxic and inexpensive gage fluid 
consists of distilled water mixed with    
a small amount of fluorescein green          
color concentrate

Convenient, portable, lightweight 
and self-contained, the unit requires  
no external power connections and 
is operated by a 1.5 volt penlight cell

A.C. detector current eliminates 
point plating, fouling and erosion

Micrometers are manufactured in accor-
dance with ASME B89.1.13-2001, and 
are traceable to a standard at the National 
Institute of Standards and Technology

•  

Three-point mounting, dual leveling 

adjustment, and circular level vial  
assure rapid setup

•  

Durablock precision-machined acrylic 

plastic gage body

•   

Sensitive 0 - 50 microamp D.C. meter 

acts as a detector and also indicates 
battery and probe condition 

•   

Heavy 2˝ thick steel base plate

provides steady mounting

•   

Top-quality glass epoxy circuit board 

and solid-state, integrated circuit 
electronics

•  

Electronic enclosure of tough, molded 

styrene acrylonitrile provides maximum 

protection to components yet allows     
easy access to battery compartment

•   

Rugged sheet steel cover and carrying 

case protects the entire unit when not 
in use

•   

Accessories included are (2) 3-foot 

lengths Tygon tubing, (2) 1/8˝ pipe 
thread adapters and 3/4 oz. bottle of 

fluorescein green color concentrate 

with wetting agent

Maximum pressure: 100 psig with
optional pipe thread connections.

Bulletin D-57

*

Patent No. 3,726,142

D-57  10/5/05  3:59 PM  Page 1

Summary of Contents for 1430

Page 1: ...red in accor dance with ASME B89 1 13 2001 and are traceable to a standard at the National Institute of Standards and Technology Three point mounting dual leveling adjustment and circular level vial assure rapid setup Durablock precision machined acrylic plastic gage body Sensitive 0 50 microamp D C meter acts as a detector and also indicates battery and probe condition Heavy 2 thick steel base pl...

Page 2: ...lifiers which act as a free run ning multivibrator operating at a frequency of approximately two kilohertz Completion of the A C circuit activates a bridge rectifier which provides the signal for indication on a sensitive 0 to 50 microamps D C microam meter 2 LOW PRESSURE FLUID LEVEL OFF ON On indication of contact the operator stops lowering the point and reads the micrometer which indicates one ...

Page 3: ...ing contact turn the point out of the fluid by turning the micrometer barrel counter clockwise to a reading of 010 or more Again watch the meter and this time lower the point by turning the micrometer barrel The point position where the meter pointer begins to move up scale is the zero position This position should correspond to the zero reading on the micrometer Adjust the point in relation to th...

Page 4: ...and dirt with a clean rag reassemble and recheck meter operation 2 If the meter operation continues to be sluggish replace the size AA 1 5 volt battery Replace the battery at least once a year to avoid deterioration of battery and damage to gage Leakproof alkaline battery is recom mended To replace the battery remove center screw Item 10 located in the back of the electronic enclosure Cover Item 9...