DWS 0P5366 Installation And Use Instructions Manual Download Page 5

5

GENERAL REMARKS -2

INSTALLATION AND USE INSTRUCTIONS

SPM8

2.1- GENERAL INSTRUCTIONS

BEFORE INSTALLING AND USING THE ACTUATOR, IT IS COMPULSORY THAT THE INSTALLER 

AND THE USER CAREFULLY READ AND UNDERSTAND THIS MANUAL IN ALL ITS PARTS.

THIS  MANUAL  IS  INTEGRAL  PART  OF  THE  ACTUATOR  AND  MUST  COMPULSORILY  BE 

PRESERVED FOR FUTURE REFERENCE.

THE  MANUFACTURER  HAS  NO  LIABILITY  FOR  ANY  EVENTUAL  DAMAGE  TO  PERSONS, 

ANIMALS AND THINGS DUE TO THE INOBSERVANCE OF THE PRESCRIPTIONS DESCRIBED IN 

THIS MANUAL.

THE WARRANTY ON THE ACTUATOR WILL NOT BE HONORED IF PRODUCT IS NOT INSTALLED AND 

USED ACCORDING TO THE INSTRUCTIONS PROVIDED AND THE REGULATIONS SHOWN IN THIS 

INSTRUCTION  MANUAL AND  IF  IT  IS  USED  WITH  NONGENUINE  PARTS, ACCESSORIES,  SPARE 

PARTS AND/OR CONTROL/FEEDING UNITS.

2.2- INSTALLER AND USER

THE  INSTALLATION  TECHNICIAN  SHALL  ACCEPT  FULL  RESPONSIBILITY  FOR  ANY 

INSTALLATION  ERRORS  AND  FOR  ANY  FAILURE  TO  ADHERE  TO  THE  INSTRUCTIONS 

PROVIDED  IN  THIS  MANUAL.  THE  INSTALLATION  TECHNICIAN  SHALL  THEREFORE  BE 

EXCLUSIVELY LIABLE FOR ANY DAMAGES CAUSED TO USERS AND/OR THIRD PARTIES THAT 

MAY ARISE AS A RESULT OF INCORRECT INSTALLATION.

IN  ORDER  FOR  THE  AUTOMATION  UNIT  TO  OPERATE  CORRECTLY,  WE  RECOMMEND 

CARRYING OUT PERIODICAL MAINTENANCE ON IT, AS INDICATED IN PAR. 7 OF THIS MANUAL.

THE ACTUATOR CAN BE USED EXCLUSIVELY BY A USER ACTING IN COMPLIANCE WITH THE 

INSTRUCTIONS CONTAINED IN THIS MANUAL AND/OR IN THE MANUAL OF THE ACTUATOR 

CONTROL DEVICE (E.G.: CONTROL UNIT).

THE ACTUATOR  INSTALLATION  CAN  BE  PERFORMED  EXCLUSIVELY  BY  COMPETENT AND 

QUALIFIED  TECHNICAL  PERSONNEL  SATISFYING  THE  PROFESSIONAL  AND  TECHNICAL 

REQUIREMENTS FORESEEN BY THE LAWS IN FORCE IN THE COUNTRY OF INSTALLATION. 

2.5-DESCRIPTION OF PERSONNEL

2.3- TECHNICAL  ASSISTANCE

User:

specialised person capable of operating the actuator under normal conditions by using the relative controls. 

He/she must also be able to operate with the actuator under “maintenance” in order to perform simple routine 

maintenance operations (cleaning), and start or reset the actuator following an unscheduled stop.

None part of this manual can be reproduced and disclosed (totally or partially) by any reproduction means 

(photocopies, microfilms or other) without written authorization of the Manufacturer.

Contact the installation technician or retailer for assistance. 

USERS MUST NEVER PERFORM OPERATIONS RESERVED FOR MAINTENANCE PEOPLE OR 

SPECIALISED TECHNICIANS. THE MANUFACTURER DECLINES ALL LIABILITY FOR DAMAGE 

DERIVING FROM FAILURE TO OBSERVE THE ABOVE REQUIREMENTS.

Each information herein contained (text, drawings, diagrams, etc.) is reserved. 

Specialised electrician:

The reserved rights on this manual "Installation and use instructions" remain property of the Manufacturer. 

2.4- RESERVED RIGHTS 

A specialised electrician must be able to install the actuator, start it and operate it both in normal conditions and 

in  the  maintenance  mode;  he/she  is  qualified  to  perform  all  electrical  and  mechanical  adjustment  and 

maintenance operations. He/she is allowed to work on live electrical cabinets and junction boxes.

Summary of Contents for 0P5366

Page 1: ...FOR THE INSTALLER AND THE USER TO READ AND UNDERSTAND THIS MANUAL IN ALL ITS PARTS ROD ACTUATOR FOR WINDOWS AUTOMATION SPM8 COD 0P5366 VER 0 0 REV 04 21 original instructions THIS MANUAL IS INTEGRAL PART OF THE ACTUATOR AND MUST BE PRESERVED FOR FUTURE REFERENCE UNTIL DEMOLITION OF THE SAME EN ...

Page 2: ......

Page 3: ...NICAL DESCRIPTION 8 DEMOLITION A1 Application window opening pag 19 4 2 1 Protection against electric hazard pag 12 5 3 Electric connections pag 14 4 2 Safety devices pag 12 3 2 Formulas for the calculation of thrust and tractive force pag 08 3 8 Application pag 11 4 3 Safety plates pag 13 8 1 General Instructions pag 18 5 5 Emergency procedures pag 15 3 7 Package pag 10 4 SAFETY 4 4 Residual risk...

Page 4: ...4 INSTALLATION AND USE INSTRUCTIONS ...

Page 5: ...TUATOR CONTROL DEVICE E G CONTROL UNIT THE ACTUATOR INSTALLATION CAN BE PERFORMED EXCLUSIVELY BY COMPETENT AND QUALIFIED TECHNICAL PERSONNEL SATISFYING THE PROFESSIONAL AND TECHNICAL REQUIREMENTS FORESEEN BY THE LAWS IN FORCE IN THE COUNTRY OF INSTALLATION 2 5 DESCRIPTION OF PERSONNEL 2 3 TECHNICAL ASSISTANCE User specialised person capable of operating the actuator under normal conditions by usin...

Page 6: ...6 3 TECHNICAL DESCRIPTION INSTALLATION AND USE INSTRUCTIONS SPM8 3 1 DIMENSIONS TECHNICAL DATA Fig 1 L 42 10 s 9 Ø 6 21 76 43 200 364 400 564 600 794 s stroke ...

Page 7: ...ON THE SAM E WINDOWS THRUST FORCE N 800 800 800 TRACTIVE FORCE N 800 800 800 TRANSLATION SPEED mm s 6 5 6 5 6 5 DURATION STROKE s 30 60 90 SERVICE TYPE S2 2 min LIM IT SWITCH OPERATING TEM PERATURE GROSS WEIGHT kg 1 8 2 4 2 9 200 400 600 POWER SUPPLY VOLTAGE V ABSORBED CURRENT A 1A 1A 1A ABSORBED POWER WHEN LOAD W 24 24 24 PROTECTION AGAINST ELECTRIC SHOCK PROTECTION DEGREE OF ELECTRIC DEVICES 3 I...

Page 8: ...rnative and more suitable product for your application IT IS COMPULSORY TO KEEP THE PACKAGE AND THE ACTUATOR OUT OF REACH OF CHILDREN THE USE OF THE ACTUATOR IN ENVIRONMENTS WITH POTENTIALLY EXPLOSIVE ATMOSPHERE IS STRICTLY FORBIDDEN The actuator has been designed and manufactured to perform by means of a command device the opening and closing of the windows 3 3 DESTINATION OF USE 3 2 FORMULAS FOR...

Page 9: ...BEWARE OF YOUR HANDS ATTENZIONE MACCHINA ADAVVIAMENTO AUTOMATICO CON COMANDOA DISTANZA ATTENTION AUTOMATIC MACHINE WITH REMOTE CONTROL DEVICE IT EN ISTRUZIONI PER L INSTALLAZIONE E L USO PRIMA DI INSTALLARE E UTILIZZARE L ATTUATORE È OBBLIGATORIO CHE L INSTALLATORE E L UTILIZZATORE LEGGANO E COMPRENDANO IN TUTTE LE SUE PARTI IL PRESENTE MANUALE ATTUATORE A CATENA PER AUTOMAZIONE FINESTRE C160 COD ...

Page 10: ...bol of WEEE Directive 2002 96 CE idle translation speed mm s absorbed electric power P W protection degree IP type and model CE marking The CE marking certifies the compliance of the machine with the essential safety and health requirements foreseen by the product European Directives symbol of double insulation only for mod SPM8 230V 3 6 RATING PLATEAND CE MARKING thrust and tractive force F N typ...

Page 11: ... AND USE INSTRUCTIONS SPM8 TECHNICAL DESCRIPTION 3 3 8 APPLICATION Fig 5 WINDOWS OPENING APPLICATION BRACKETS STROKE S1 SA 200 400 600 A1_1 A1_2 W F W F PARALLEL ANGULAR W windows F Frame W windows F Frame SA SA S1 S1 ...

Page 12: ...DURING HANDLING AND INSTALLATION OF THE PARTS THE PERSONNEL SHALL BE EQUIPPED WITH SUITABLE PERSONAL PROTECTION EQUIPMENT PPE SO AS TO PERFORM THE WORKS REQUIRED UNDER SAFE CONDITIONS THE MAINTENANCE OPERATIONS INVOLVING THE TOTAL OR PARTIAL DISMOUNTING OF THE ACTUATOR MAY ONLY BE PERFORMED AFTER DISCONNECTING IT FROM THE POWER SUPPLY WITH THE APPLIANCE 3 Only for Mod SPM8 230V equipped with doubl...

Page 13: ...e damage Light lesions usually reversible IT IS FORBIDDEN TO REMOVE MOVE SPOIL OR IN ANYWAY REDUCE THE VISIBILITY OF THE SAFETY PLATES FAILURE TO OBSERVE THE ABOVE MAY CAUSE SERIOUS HARM TO PEOPLE AND DAMAGE TO PROPERTY THE MANUFACTURER DECLINES ALL LIABILITY FOR ANY DAMAGE CAUSED BY THE FAILURE TO OBSERVE THE ABOVE REQUIREMENT 4 3 SAFETYPLATES In Fig 6 illustrates the safety plate this must appli...

Page 14: ...ELECTRIC CONNECTION OF THE ACTUATOR PAR 11 CAN BE PERFORMED ONLY BY COMPETENT AND QUALIFIED TECHNICAL PERSONNEL FORESEEN BY THE LAW IN FORCE IN THE COUNTRY OF INSTALLATION WHO CAN ISSUE TO THE CUSTOMER A DECLARATION OF CONFORMITY FOR THE CONNECTION AND OR PLANT CARRIED OUT BEFORE PERFORMING THE ELECTRIC CONNECTION OF THE ACTUATOR VERIFY THE CORRECT INSTALLATION ON THE WINDOW THE MAINS TO WHICH THE...

Page 15: ...Fig 7 Act on the screw V1 by unscrewing the 2 Open the window manually DEVICES BEFORE PERFORMING ANY TYPE OF TRIPPING ON THE ACTUATOR AND ON THE WINDOW IT IS COMPULSORY TO DISCONNECT THE POWER SUPPLY OF THE ACTUATOR AND TO PUT ON 0 THE EVENTUAL SWITCHES OF THE CONTROL IT IS COMPULSORY TO PADLOCK THE MAIN SWITCH OF THE DISCONNECTION DEVICE INSTALLED ON THE MAINS IN ORDER TO AVOID ANY UNEXPECTED STA...

Page 16: ...ing or closing and therefore at subsequent openings the stroke will be automatically reduced to the obstacle even if this is removed To restore the final stroke manually it will be sufficient once the obstacle is removed to position the machine near the original final stroke and activate the manual command in open close for 4 cycles it is not necessary to complete the whole cycle but it is suffici...

Page 17: ...HE SAFETY FEATURES SET OUT IN APPLICABLE LEGISLATION OBSERVING THE INSTRUCTIONS FOR MAINTENANCE AND USE PROVIDED BY THE MANUFACTURER OF THE DEVICE AND BY THE COMPANY THAT CARRIED OUT THE INSTALLATION BEFORE OPERATING THE ACTUATOR THE USER MUST COMPULSORILY VERIFY THAT NEAR AND OR UNDER THE WINDOW THERE ARE NOT ANY PERSON ANIMAL AND THING WHOSE SAFETY MAY BE ACCIDENTALLY JEOPARDISED SEE PAR 4 DURIN...

Page 18: ...ESSORIES UPON REQUEST 9 DISPOSAL 8 SPM8 MAINTENANCE 7 The actuator incorporates components that do not require significant routine or extraordinary maintenance operations The recommended maintenance activities should in any case involve the periodical execution every 6 mounths of at least the following operations that the actuator assembly components are clean the replacement of components that sh...

Page 19: ...1 112 36 164 17 5 32 5 8 5 23 5 43 61 68 32 5 10 W F SA S1 Stroke L mm 200 412 400 612 600 842 WINDOW OPENING Top hung Outward opening Bottom hung Outward opening Bottom hung Inward opening Skylight or dome Stroke 200 400 600 24V 230V Standard Casement Frame W F SA S1 19 INSTALLATION AND USE INSTRUCTIONS INSTALLATION AND USE INSTRUCTIONS ...

Page 20: ...he seals as to obtain a good closing of the window f r a m e T h e n fi x t h e screws V2 8 Perform the electrical connections as described see Cap 5 3 0 Set hypothetical stroke end for the complete opening of the window Fig 15 to 18 1 Fig 8a With a pencil draw the centre line X of the window frame 6 Fig 13a After having verified that the window frame is in closing position fix the thrust rod head T1...

Page 21: ... Then fix the screws V2 5 Fig 12b Make sure that the rod is fully retracted into the actuator In SYNCRO application the r o d s m u s t A L L b e r e t r a c t e d b e f o r e energizing the actuators Insert the M2 clamps in the G guides on the sides of the actuator 1 Fig 8b With a pencil draw the centre line X of the window frame 3 Fig 10b Drill the frame of the window and fix the actuator support ...

Page 22: ...6 Fig 15 Lt with Lt 800mm L1 200 to have a window opening of move A of Ln 600 Example SPM8 1 REMOVE Lt Total stroke 2 UNSCREW Ln Lt L1 L1 A 3 MOVE A Ln Ln Ln window opening 5 INSTALL Fig 16 Fig 17 Fig 18 4 FIX 22 INSTALLATION AND USE INSTRUCTIONS ...

Page 23: ... CLOSE not used grey black brown orange yellow green 230 Vac Single DAMAGE TO THE ACTUATOR CAUSES IRREPARABLE CAUTION A WRONG CONNECTION 230Vac Electrical scheme 230V Single TO GUARANTEE THE DEGREE OF IP PROTECTION STATED IT IS NECESSARY TO TIGHTEN THE SCREWS OF THE COVER AND CABLE GLAND WITH A 1 5Nm PAIR note unused green cable ...

Page 24: ...les yellow orange green black grey brown black grey brown orange yellow green SPM8 230V 230Vac Electrical scheme 230V Double TO GUARANTEE THE DEGREE OF IP PROTECTION STATED IT IS NECESSARY TO TIGHTEN THE SCREWS OF THE COVER AND CABLE GLAND WITH A 1 5Nm PAIR SYNC Double THE RODS MUST ALL BE RETRACTED BEFORE ENERGIZING THEACTUATORS ATTENTION IF YOU HAVE A SYNC APPLICATION DO NOT ENERGIZED THE SPM8 B...

Page 25: ...AUTION A WRONG CONNECTION 2 1 GREY BROWN grey brown SPM8 24V CLOSE 24V OPEN 24V CC min 21V max 28V 3 4 5 not used yellow orange green Electrical scheme 24V Single TO GUARANTEE THE DEGREE OF IP PROTECTION STATED IT IS NECESSARY TO TIGHTEN THE SCREWS OF THE COVER AND CABLE GLAND WITH A 1 5Nm PAIR note unused green cable and black cable ...

Page 26: ... SYNC 24 Vdc Double 24V SPM8 24V SPM8 24V 3 CLOSE 24V OPEN 24V CC min 21V max 28V grey brown 4 5 3 24Vdc TO GUARANTEE THE DEGREE OF IP PROTECTION STATED IT IS NECESSARY TO TIGHTEN THE SCREWS OF THE COVER AND CABLE GLAND WITH A 1 5Nm PAIR SYNC Double THE RODS MUST ALL BE RETRACTED BEFORE ENERGIZING THEACTUATORS ATTENTION IF YOU HAVE A SYNC APPLICATION DO NOT ENERGIZED THE SPM8 BEFORE INSTALLATION I...

Page 27: ...27 INSTALLATION AND USE INSTRUCTIONS ...

Page 28: ...28 INSTALLATION AND USE INSTRUCTIONS ...

Page 29: ......

Page 30: ......

Reviews: