Installing and Connecting the Unit
17
Warning:
The signal from the relay output of the unit is for use as an indicator, not for direct control
of a device.
Caution:
To prevent damage to the unit, do not exceed the voltage and current ratings for the relay
terminals.
3.3
Resetting the Unit
The unit can be reset to previous settings as follows:
(page 17)
Reset by Removing the Power Supply
(page 17)
3.3.1
Reset Using the RESET Button
The camera has a reset button located on the back panel. See Figure 5: trk100/trk100d Back Panel (page 4)
and Figure 7: trk200 Back Panel (page 6).
To reset a unit using the RESET button
1.
Insert a small pointed object into the hole labeled
RESET
on the back panel of the camera.
2.
Press in and release. The unit resets to the previous settings.
3.3.2
Reset by Removing the Power Supply
The unit can be reset by turning off the power and then turning it on again.
To reset a unit by removing the power supply
1.
Turn off or disconnect the power to the unit.
2.
Turn on or reconnect the power to the unit. The unit restarts with the previous settings.
3.4
Solo Setup
The Solo Setup function enables you to install and setup a camera at the remote site without requiring
another person’s assistance. With this function, you can:
Use the camera to record a set of snapshots of the scene while the user is moving around the
camera field of view
Move around within the camera’s field of view
Use the recording of his movement to setup the depth by marking a person’s height on the
camera’s field of view
For instructions on how to use the Solo Setup, see page 22 in the