![DVTEL Ioimage trk-101 Installation Manual Download Page 26](http://html1.mh-extra.com/html/dvtel/ioimage-trk-101/ioimage-trk-101_installation-manual_2544223026.webp)
trk-101 Installation Manual
14
3.3.1
Reset Using the RESET Button
The unit has a reset button located on the power connection panel of the unit. See
Figure 3: trk-101 Power
Connection Panel
(page 2).
To reset a unit using the RESET button
1.
Insert a small pointed object into the hole labeled RESET on the power connection panel of the
unit.
2.
Press in and release the button within 5 seconds. The unit resets to its last settings and the LED
flashes green.
3.3.2
Reset by Removing the Power Supply
The unit can be reset by turning off the power and then turning it on again.
To reset a unit by removing the power supply
1.
Turn off or disconnect the power to the unit.
2.
Turn on or reconnect the power to the unit. The unit restarts with the last settings.
3.4
Solo Setup
The Solo Setup function enables you to install and setup one or more cameras at the remote site without
requiring another person’s assistance. With this feature, you can:
Use the camera to record a set of snapshots of the scene while the user is moving around the
camera field of view
Move around within the camera’s field of view
Use the recording of his movement to setup the depth by marking his height on the camera’s
field of view.
For instructions on how to use the Solo Setup function, see page 22 in the
Appendix
.
3.5
Batch Solo Setup Recording
It is possible to configure Solo Setup recording (single person depth setup) of multiple ioimage units. For
details how to use this function, see the training video and
Appendix
(page 24).
3.6
Noise Reduction
To add 2D Noise Reduction, select
Enable Noise Reduction
on the
Setup > Camera > Video Settings >
Advanced
tab.