background image

OPERATING GUIDELINES FOR THE DVS-5E SYSTEM 

Your 

DVS

®

 has been configured and the airflow and settings  individually  calibrated to the size of  your 

home,  however  it  can  be  easily  adjusted  to  suit  changing  family  circumstances,  the  seasons,  and 
weather. When you are more familiar with your 

DVS

®

 we encourage you to experiment by changing and 

customising the control settings to better suit your home and circumstances, and to get the maximum 
benefits from your investment in the 

DVS

®

 

Touch Pad control panel 

The DVS-5E touch pad (at right) enables you to: 

Select pre-programmed ‘Summer’ or ‘Winter’ operating modes; 

Adjust the airflow from your DVS

®

; and 

Re-program the Filter Reminder light. 

AIRFLOW Indicator Bar and Controls

Functions of the AIRFLOW Indicator Bar 

The AIRFLOW Indicator Bar indicates whether your DVS-5E is currently 
operating, and the airflow setting.  By using the MORE or LESS arrows on 
the touch pad you can: 

Increase or decrease the airflow;  

Turn your DVS

®

 OFF; or 

Turn your DVS

®

 on FULL speed (for short periods of time if required). 

Indicator Bar Lights 

The Indicator Bar consists of eight orange (or yellow) lights and one red light. 

Red Light 
An  illuminated  red  light  indicates  that  the  DVS

®

  has  been  manually  switched  off  or  the  fan  has 

automatically  switched  itself  off  when  the  system  is  in  SUMMER  mode  and  the  roof  temperature  is 
above 19 ºC. Note that when the system has been manually switched off all the orange lights will also 
be extinguished.   

Orange Lights 
The orange lights indicate the speed of the AIRFLOW being delivered into your home.  Each light can be 
illuminated  on  a  half  light  or  full  light  level,  meaning  it  is  possible  to  set  the  AIRFLOW  to,  say,  3½ 
lights, as well as 3 or 4 lights. 

DVS-5E Climate 

Controlled Touch Pad. 

Summary of Contents for DVS-5E

Page 1: ...icator Bar indicates whether your DVS 5E is currently operating and the airflow setting By using the MORE or LESS arrows on the touch pad you can Increase or decrease the airflow Turn your DVS OFF or Turn your DVS on FULL speed for short periods of time if required Indicator Bar Lights The Indicator Bar consists of eight orange or yellow lights and one red light Red Light An illuminated red light ...

Page 2: ...LESS arrow to decrease the airflow Each press of the MORE or LESS arrow is equivalent to a half increase or decrease in the orange lights illuminated on the Indicator Bar Therefore two pushes of an arrow are required to fully turn on or turn off one full orange light NOTE that while the airflow level is indicated by the number of lit orange lights because of the way each DVS is calibrated six illu...

Page 3: ...etting will be indicated by an illuminated light SUMMER Setting On the SUMMER setting your DVS will automatically switch off when your roof space temperature exceeds 19ºC to prevent your home becoming unpleasantly hot and will switch back on when your roof space cools to below 19º C WINTER Setting On WINTER setting your DVS will automatically switch to heat recovery mode increasing the airflow whe...

Page 4: ... will automatically reset to a 12 month reminder d Exit the filter reminder set up by pressing the WINTER SUMMER select button again until the lights stop flashing Your filter light is now re set Other Optional DVS Equipment If your DVS 5E has been supplied with other DVS optional equipment such as a DVS Air Warmer please refer to the separate Operating Guidelines supplied at the time of installat...

Page 5: ...are illuminated but no other lights are Please contact us on 0800 DVS DVS 387 387 Standard Requirement In accordance with NZ Standard AS NZS60335 1 2002 7 12 This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely Young children should be supervised to ensure that...

Reviews: