Faucet Installation Guide:

1. Remove retaining nut and washers (B,C,D) from the threaded retaining post (A).

2. With the retaining post (A) screwed into the faucet ring (F), insert the stainless steel

     supply lines (G) and  retaining post (A) through the faucet hole in your counter top.

3. While supporting the faucet, reinstall the rubber washer (B), metal washer (C) and

     retaing nut (D).  Screw the locking screws (E) out of the retaining nut until they 

     become flush with the bottom of the retaining nut (D). 

4. Tighten the retaining nut (D) until it contacts the metal washer (C) on the underside

     of the counter top and snug the locking screws using a phillips head screwdriver

     being sure not to over tighten.

5. Connect the water supply lines (G) to the shut-off valves (I) via the attached 

     compression fitting (H) with an adjustable wrench being sure not to over tighten.

6. Remove the faucet aerator end (J) before turning the water supply on to ensure

     debris in the lines passes through easily being sure to flush both the hot and cold

     lines before reinstalling the aerator.

M

Drain Installation Guide:

1.  Unscrew drain tube (#6) 

     from drain body and wrap

     tephlon tape around

     threaded end of drain tube (#6).

2.  Unscrew lock nut (#5) from 

     drain body.  Remove gasket 

     (#3), and  washer (#4) from 

     drain body.  Screw the drain

     tube (#6) back into drain body.

3.  Put a bead of 100% Silicone

USE OF PLUMBERS PUTTY VOIDS WARRANTY

USE OF PLUMBERS PUTTY VOIDS WARRANTY

     sealer under flange (#1), or

     use flange gasket (#2) and 

     insert threaded end of drain

     body down through drain hole.

4.  Replace gasket (#3) beveled

     side up, then the washer (#4) and 

     thread up lock nut (#5) from the underside of the lavatory sink until the black rubber (#3) gasket is seated

     securely inside the opening of the drain hole in the counter top.   Tighten lock nut (#5) carefully, wiping

     excess silicone from around the edge of the flange (#1).  

 Ideally, it is best to wait 24 hours and tighten

 further to allow for a solid silicone seal. Over tightening can squeaze out too 

     much silicone possibly

preventing a proper seal. Allow 24 hours for sealant to set. 

DO NOT OVERTIGHTEN OR 

      DAMAGE WILL OCCUR!

DO NOT OVERTIGHTEN OR 

      DAMAGE WILL OCCUR!

5.  Install drain t rap assembly and leak test all connections.

6

4

3

1

5

MAXIMUM

COUNTERTOP

THICKNESS = 2-1/2"

2

D’VONTZ  •  7208 EAST 38th STREET  •  TULSA, OKLAHOMA  74145 

918.622.3600  • FAX 918.622.3649  •  WWW.DVONTZ.COM

If you have any trouble during the installation of your D’Vontz drain, please call our Customer Service

department at 918-622-3600.

Congratulations on the successful installation of your D’Vontz faucet!

LIMITED WARRANTY

Use of any cleaning products other than those suggested by D’Vontz will void warranty. See
care and installation instructions included with product or available on the web at

www.dvontz.com

.

Use of “plumber’s pu y” on any product will void all warranties!

All D’Vontz products are warranted to the original purchaser to be free of defects in material
and workmanship for one year from the purchase date.

This limited warranty only applies to the original purchaser of our product. Proof of Purchase
in the form of the original sales receipt will be required for any warranty claim.

This limited warranty does not cover any costs associated with a product’s removal and/or
reinstallation, including labor, materials or damage to surrounding products or goods.

There is no warranty on copper sink or tub patinas. Please refer to the care instructions

included with these products.

D’V