13
DVDO-Matrix-44-Mini_V1.0.0
DVDO
DVDO-Matrix-44-Mini 4x4 HDMI Matrix with Audio Outputs
User Manual
Before executing the API command through RS232 serial connection, please
ensure RS232 interface of the device and the control PC are configured
correctly.
Parameters
Value
Baud Rate
115200 bps
Data Bits
8 bits
Parity
None
Stop Bits
1 bit
Flow Control
None
Web UI Control
The Web UI designed for the matrix is available for switching control, general
and advanced settings. The Web UI is accessible through a browser with latest
version, e.g. Chrome, Firefox, Safari, Opera, IE10+, etc.
Access the Web Interface
1. Connect the IP Control port of the matrix to the Ethernet switch, and connect
your PC to the same network.
Note:
The IP mode of the matrix is DHCP, please ensure the Ethernet
switch is connected to a DHCP server.
2. Use the tool such as SmartSetGUI to search the IP address of the device or
send API command to get IP address
(See the separate document “API
Command Set_DVDO-Matrix-44-Mini
”).
3. Input the IP address in your browser and press Enter to enter the login
page.
4. Enter the username and password in the following login page, then click
“
Login
”. The default username and password are both “
admin
”.