background image

Control  Box  Instruction Manual 

--------------------------------

[2  &  [101 Control  box instruction 

Parts List 

Item 

Parts Name 

Q'TY  Material  Item 

Parts Name 

Q'TY  Material 

1  Cover 

1  ST.ST 304  15  Screw(M6x15Ll 

2  ST.ST 304 

2  O-Rinq(75. 92x1. 78)

1  NBR 

16  Air connection 

1  Plastic 

3  Screw(M3x10L) 

4  ST.ST 304  17  Air connection 

[upper 

4  LED Light board 

-----

18  Screw(PT1/8") 

1  ST.ST 304 

5  Fixinq piece 

2  NYLON 66  19  Air manifold 

1  ST.ST 304 

6  Micro switch 

-----

20  O-Rinq(11x3)

1  NBR 

7  Proximity sensor 

------

21  Screw(M5x10L) 

2  ST.ST 304 

8  Screw(M3x15L) 

4  ST.ST 304  22  Cable 

-----

9  Screw 

1  ST.ST 304  23  Circuit board 

-----

10  Exhaust pipe 

-----

24  Screw(M3x8L) 

4  ST.ST 304 

11  Gasket 

2  PE 

25  Screw(M5x12Ll 

2  ST.ST 304 

12  Electroval ve 

-----

26  Cable head 

1  NYLON 66 

13 

Stent-A 

1  POM 

27  O-Rinq(73x1.85)

1  NBR 

14  Stent-B 

1  POM 

28  Contact head 

1  ST.ST 304 

04 

Summary of Contents for C2

Page 1: ...r 4 LED Light board 1 18 Screw PT1 8 1 ST ST 304 5 Fixinq piece 2 NYLON 66 19 Air manifold 1 ST ST 304 6 Micro switch 2 20 O Rinq 11x3 1 NBR 7 Proximity sensor 2 21 Screw M5x10L 2 ST ST 304 8 Screw M3x15L 4 ST ST 304 22 Cable 1 9 Screw 1 ST ST 304 23 Circuit board 1 10 Exhaust pipe 1 24 Screw M3x8L 4 ST ST 304 11 Gasket 2 PE 25 Screw M5x12Ll 2 ST ST 304 12 Electrovalve 1 26 Cable head 1 NYLON 66 1...

Page 2: ...O NC BU OV V DC12 3DV Electrovalve 108 D30 0788 W5078 24V DC 100 ED RN05 NP BN 1 V I DV BK NPN NO NC WH PNP NO NC BU OV V DC12 3OV t Proximity switch 2 Fastening arrangemtnt on actuator top t Air in Use hand operator of the solenoid valve activate the actuator 8 Brown Black _ White Black Black 05 3 t Air in 6mm air tube Micro switch D25SW 3L2M Electrovalve 108 030 D788 W5D78 24V DC 10D ED Micro sw...

Page 3: ...he connection hwad and screw it to the stern A 9 C2 NC Normally closed Air in Put the contact head on the housing screw M6x1 0 screws 10 C101 NC Normal y closed C2 NO Normal y open Air in _ _ 12 13 14 06 Put on the bottom set and press down Rmmbec 0 g 11 C101 NO Normally open Air in 15 ...

Page 4: ...NP Wiring diagram for Control Box Constant supply voltage 24VDC on terminals 0V and 24V Supply 24VDC to terminal CTR to activate solenoid valve and open the valve Feedback comes as 24VDC on terminals R and G for open and close respectively Wiring terminals 1 24V 1 0V 1 R 1 G 1 CTR 1 0V 1 24V 1 1 1 NC 4 3 2 1 NC 1 HEADER 4 NPN 4 3 2 1 NO 1 HEADER 4 PNP 0V 24V Coil 0V or 24V 1 CTR 1 NPN PNP 24V 1 1 ...